In addition to the site plan requirements, as specified in the Administration, Enforcement and Appeals Section of this Development Ordinance, or in any other applicable local ordinances or regulations, all applications for a local Development Permit within the River/Stream Corridor Protection District shall also include a detailed site plan, drawn at a scale of 1" = 50', with the following information:
a) A map of all planned excavation and fill, including calculations of the volume of cut and fill involved, cross‐ sectional drawings showing existing and proposed grades. Elevations, horizontal scale and vertical scale must be shown on the cross‐sectional drawings.
b) A map of any wetland and floodplain boundaries occurring within the site must be provided. This boundary may be included on other maps provided by the applicant.
c) Location, dimensions and area of all impervious surfaces, both existing and proposed, on the site and adjacent to the site for a distance of 200 feet.
d) The orientation and distance from the boundaries of the proposed site to the nearest bank of an affected perennial stream or water body.
e) Elevations of the site and adjacent lands within 200 feet of the site at contour intervals of no greater than two feet; and no greater than one foot for slopes less than or equal to two percent.
f) All proposed temporary disruptions or diversions of local hydrology.
Read this code where it is posted (county website (oglethorpecountyga.gov)) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.