All Manufactured Housing locating or relocating within the County shall meet the following minimum requirements: a) Each manufactured housing unit shall be installed according to the manufacturer's installation instructions (when available), or Appendix "H" of the Georgia State Building Code, whichever is stricter, and shall include the use of approved tie‐downs and ground anchors sufficient to withstand winds of 100 miles an hour, so as to resist wind overturning and sliding; b) The foundation must be enclosed by a curtain wall, manufactured skirting material, masonry construction, or other material manufactured for such purpose. Materials not manufactured for such purpose may be used if approved by the Oglethorpe County Board of Commissioners or their designated official(s) prior to installation. Material not manufactured for such purpose must be installed to the same standards as materials manufactured for such purpose. c) Each manufactured/mobile home must be provided with prefabricated or permanent stairs with landing, constructed from pressure treated lumber, masonry, or metal, sufficient to provide ingress and egress from two (2) exterior doors of the manufactured/mobile home unit. Loose stacked steps are strictly prohibited. Said Landing dimensions shall be a minimum of three (3’) feet by three (3’) feet. If over thirty (30”) inches above the ground, handrails and guardrails shall be required. d) Owners shall be allowed three (3) months after issuance of a building permit in which to complete underpinning and landings. e) Where stricter standards or requirements are specified herein, or in the Oglethorpe County Rules and Regulations for Manufactured Housing and Mobile Homes, Minimum, Standards for Installation Requirements, those stricter standards or requirements shall apply.