--- title: Oglethorpe County Zoning Ordinance, Section 710.05. Private Residential Pool Requirements collection: local-codes id: local-code:oglethorpe-county/zoning/710.05 cite_as: Oglethorpe County, Ga., Zoning Ordinance § 710.05 canonical_url: https://georgiacommons.org/code/local/oglethorpe-county/zoning/710.05 md_url: https://georgiacommons.org/code/local/oglethorpe-county/zoning/710.05.md text_url: https://georgiacommons.org/code/local/oglethorpe-county/zoning/710.05/text source_url: https://www.oglethorpecountyga.gov/_files/ugd/2dc561_a1ee38edc049440c8711e73fa9a719da.pdf date: 2026-11-23 status: active jurisdiction: county:oglethorpe jurisdiction_name: Oglethorpe County county_fips: "13221" corpus_version: local-codes-oglethorpe-county-9e77fd875fbd publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/code/local/oglethorpe-county/zoning/~article-vii.md previous: https://georgiacommons.org/code/local/oglethorpe-county/zoning/710.04.md next: https://georgiacommons.org/code/local/oglethorpe-county/zoning/710.06.md index: https://georgiacommons.org/code/local/oglethorpe-county.md branch: zoning edition: As posted on the county's website, retrieved 2026-11-23 edition_date_kind: retrieved source_publisher: county website (oglethorpecountyga.gov) version_id: local-code:oglethorpe-county/zoning/710.05@2026-11-23-6e3eb42b9f --- # Oglethorpe County Zoning Ordinance, Section 710.05. Private Residential Pool Requirements > As posted on the county's website, retrieved 2026-11-23 Part of: Article VII - Specific Provisions All newly constructed or installed private residential pools, hot tubs, or spas shall be completely surrounded with a barrier meeting the following requirements, unless otherwise provided, herein: a. The exterior wall(s) of a dwelling house or accessory building may be incorporated as a part of the barrier. b. The top of the barrier shall be at least forty‐eight inches (48") above grade measured on the side of the barrier which faces away from the pool. The maximum vertical clearance between grade and the bottom of the barrier shall be four inches (4") measured on the side of the barrier which faces away from the pool. c. Openings in the barrier shall not allow passage of a four‐inch (4") diameter sphere. d. Solid barriers that do not have openings, such as a masonry or stone wall, shall not contain indentations or protrusions except for normal construction tolerances and tooled masonry joints. e. Where the barrier is composed of horizontal and vertical members and the distance between the tops of the horizontal members is less than forty‐five inches (45"), the horizontal members shall be located on the pool side of the fence. Spacing between vertical members shall not exceed one and one‐fourth inches (1 1/4") in width. Where there are decorative cutouts within vertical members, spacing within the cutouts shall not exceed one and one‐fourth inches (1 1/4") in width. f. Where the barrier is composed of horizontal and vertical members and the distance between the tops of the horizontal members is forty‐five inches (45") or more, spacing between vertical members shall not exceed four inches (4"). Where there are decorative cutouts within vertical members, spacing within the cutouts shall not exceed one and one‐fourth inches (1 1/4") in width. g. Maximum mesh size for chain link fences shall be one and one‐fourth inches (1 1/4") square unless the fence is provided with slats fastened at the top or the bottom which reduce the openings to no more than one and one‐fourth inches (1 1/4"). h. Where the barrier is composed of diagonal members, such as a lattice fence, the maximum opening formed by the diagonal members shall be no more than one and one‐fourth inches (1 1/4"). i. Where the top of the pool structure is above grade, such as an above‐ground pool, the barrier may be at ground level, such as the pool structure. Where the barrier is mounted on top of the pool structure, the maximum vertical clearance between the top of the pool structure and the bottom of the barrier shall be four inches (4"). Where an above‐ground pool structure is used as a barrier or where the barrier is mounted on top of the pool structure, and the means of access is a ladder or steps, then the ladder or steps shall be capable of being secured, locked or removed to prevent access; or the ladder or steps shall be surrounded by a barrier which meets the requirements of this section. When the ladder or steps are secured, locked or removed, any opening created shall not allow the passage of a four‐inch (4") diameter sphere. j. All gates or doors opening through the enclosure shall be equipped with a self‐ closing and self‐latching device for keeping the gate or door securely closed at all times when not in actual use, except that the door of any dwelling which forms a part of the enclosure need not be so equipped. Where the release mechanism of the self‐latching device is located less than fifty‐four inches (54") from the bottom of the gate, then the release mechanism shall be located on the pool side of the gate at least three inches (3") below the top of the gate and the gate and barrier shall have no opening greater than one‐half inch (1/2") within eighteen inches (18") of the release mechanism. k. Barriers shall be located so as to prohibit permanent structures, equipment or similar objects from being used to climb the barriers.