--- title: Oxford Zoning Ordinance, Sec. 40-426. Building form standards; building type collection: local-codes id: local-code:oxford/zoning/40-426 cite_as: Oxford, Ga., Zoning Ordinance § 40-426 canonical_url: https://georgiacommons.org/code/local/oxford/zoning/40-426 md_url: https://georgiacommons.org/code/local/oxford/zoning/40-426.md text_url: https://georgiacommons.org/code/local/oxford/zoning/40-426/text source_url: https://library.municode.com/ga/oxford/codes/code_of_ordinances date: 2025-06-02 status: active jurisdiction: city:oxford jurisdiction_name: Oxford place_fips: "1358744" corpus_version: local-codes-oxford-41493932f583 publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/code/local/oxford/zoning/~part-ii/~chapter-40/~article-ii/~division-14.md previous: https://georgiacommons.org/code/local/oxford/zoning/40-425.md next: https://georgiacommons.org/code/local/oxford/zoning/40-427.md index: https://georgiacommons.org/code/local/oxford.md branch: zoning edition: As published by Municode, current through 2025-06-02 edition_date_kind: current_through source_publisher: Municode version_id: local-code:oxford/zoning/40-426@2025-06-02-30e4ef29a1 --- # Oxford Zoning Ordinance, Sec. 40-426. Building form standards; building type > As published by Municode, current through 2025-06-02 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Part II - CODE OF ORDINANCES / Chapter 40 - ZONING / Article II - ZONING DISTRICTS / Division 14 - TOWN CENTER DISTRICT (TC) (a) Type 1, shopfront building. The shop-front building is a one-story commercial or retail building that fronts the public sidewalk. (1) Height regulations. a. Minimum floor height: 12 feet (one story). b. Maximum floor height: 15 feet (one-story). c. Maximum building height in TC. d. District: 20 feet total with roof/parapet wall. commercial or retail building that fronts Minimum Floor Height: 12 ft. (one story) Maximum Floor Height: 15 ft. (one-story) Maximum Building Height in TC 20 ft. total with roof/parapet wall. Minimum: 20 ft.; Maximum: 40 ft. Street Parking Requirements One space per 500 square feet of Roof Height: Max. 5 ft. parapet wall. Patios permitted for outdoor dining. Awning Depth: 4 ft. maximum. (2) Building and lot standards. a. Lot width. 1. Minimum: 20 feet; 2. Maximum: 40 feet. b. Setbacks. See sections 40-29 through 40-31. (3) Off-street parking requirements. One space per 500 square feet of retail. (4) Additional requirements. a. Roof height: maximum five feet parapet wall. b. Patios permitted for outdoor dining. c. Awning depth: four feet, maximum. (b) Type 2, mixed-use building. (1) Description. A mixed-use building has two or more floors, and allows the flexibility of having a vertical mixture of uses. The ground floor may be used for retail or office uses, while upper floors may be used for office, residential or lodging. (2) Mixed-use standards. a. Height regulations. 1. Minimum floor height. (i) 12 feet, first floor; (ii) Ten feet, second floor; (iii) Ten feet, third floor; (iv) 22 feet (two-story); (v) 32 feet (three-story). 2. Maximum floor height. (i) 15 feet, first floor; (ii) Ten feet, second floor; (iii) Ten feet, third floor; (iv) 25 feet (two-story); (iv) 35 feet (three-story); (v) Maximum building height in TC district: 40 feet total with parapet wall. Use building has two or more office uses, while upper floors may be b. Building and lot standards. 1. Lot width: minimum 20 feet. 2. Setbacks: see sections 40-29 through 40-31. c. Off-street parking requirements. 1. One space per dwelling unit. 2. One space per 500 square feet of retail/office. d. Additional requirements. 1. Parapet wall: five feet maximum 2. Balcony depth: six feet maximum. 3. Patios permitted for outdoor dining. 4. Awning depth: six feet maximum. Street Parking Requirements (c) Type 3, live/work building. (1) Description. A live/work building is a residential dwelling with a home office or retail component. The office or commercial component of the building is limited to the ground floor. (2) Live/work standards. a. Height regulations. 1. Minimum floor height. (i) 12 feet, first floor; A Live/Work building is a residential dwelling with a home office or retail (ii) Ten feet, second floor; (iii) 22 feet (two-story). 2. Maximum floor height. (i) 15 feet, first floor; (ii) Ten feet, second floor; (iii) 25 feet (two-story). 3. Maximum building height in TC district: 30 feet total with parapet wall. b. Building and lot standards. 1. Lot width. (i) Minimum: 20 feet; (ii) Maximum: 40 feet. 2. Setbacks: see sections 40-29 through 40-31. c. Off-street parking requirements. One space per dwelling unit. One space per 500 square feet of retail/office. d. Additional requirement. 1. Parapet wall: five feet maximum. 2. Porch depth: six feet maximum; no porch on ground level. 3. Awning depth: same as porch depth. (d) Type 4, civic building. (1) Description. A building designed specifically for a civic purpose, such as government offices, schools, libraries, courthouses, or other similar purposes. (2) Civic building standards. a. Height regulations. 1. Minimum floor height. (i) 12 feet, first floor; (ii) Ten feet, second floor; (iii) Ten feet, third floor; (iv) 22 feet (two-story); (v) 32 feet (three-story). 2. Maximum floor height. (i) 15 feet, first floor; (ii) Ten feet, second floor; (iii) Ten feet, third floor; (iv) 25 feet (two-story); (v) 35 feet (three-story). 3. Maximum building height in TC district: 40 feet total with roof/ parapet wall. b. Building and lot standards. 1. Lot width: minimum 30 feet; no maximum. 2. Setbacks: see sections 40-29 through 40-31. c. Off-street parking requirements. One space per 300 square feet of gross floor area. Maximum Building Height in TC District: One space per 300 square feet of gross d. Additional requirements. 1. Maximum five feet parapet wall. 2. Porch depth: ten feet maximum. ## History (Code 1997, § 40-414; Ord. of 2-6-2012, § 1(40-414))