A. Applicability. The form-based requirements for the residential districts apply to properties with frontage on existing streets, as shown on the Regulating Plan. Any lot or parcel created after the effective date of this ordinance shall be subject to the requirements of Section 10-7.
B. Purpose and Intent. Implementation of the dimensional requirements of the residential form-based districts realizes a complementary residential development pattern that is based on traditional neighborhood design principles. It also ensures that a consistent architectural character is maintained and the street is neither dominated nor defined by imposing garages that project beyond the front façade of a building. Such a pattern will additionally help support a walkable, pedestrian environment and promote neighborhood accessibility. By regulating building character, facades can be located closer to a street and sidewalk and be aligned to form an edge that frames the public realm, while retaining sufficient room for people to walk and mingle with neighbors. Further, as expressed by traditional architectural forms, defined building entrances, window openings, materials and heights, new structures can be designed to blend with existing homes, thereby enhancing the character of residential neighborhoods.
C. Lot Area, Siting, and Height Standards. Specific dimensional standards for the residential form-based districts are specified as follows:
a. Lot Standards.
i. Lot area.
(A) R-3A District: Min. 5,000 sq. ft.; max. 8,000 sq. ft.
(B) R-3B District: Min. 10,000 sq. ft.; max 20,000 sq. ft.
ii. Minimum Lot Width.©
(A) R-38A District: 50 ft.
(B) R-3B District: 90 ft.
b. Street Facade.
i. The front building facade shall be parallel to the adjacent street and/or sidewalk.®
ii. For an addition or new structure:
(A) R-3A District: Where there is an existing and inconsistent pattern of build-ing placement, the RBL shall be equal to the average of the front setbacks of existing principal buildings located on the same side of the street, in the same zoning district as the subject parcel, and within 200 ft. of the lot where build-ing placement is being established. Where there is no established dimension, the RBL shall be between 15 ft. and 20 ft.©
(B) R-3B District: The RBL shall be between 25 ft. and 30 ft.© Building Standards: R-3A Traditional Residential District:
{}——> Building Standards: R-3B Mill Village District ili. The front facade of the principal building shall occupy at least 60% of the lot frontage at the RBL. For lots 150 ft. wide or more, requests to relax this requirement shall be considered as a deviation instead of a variance (see Sec-tion 10-8).®
iv. On corner lots, the RBL shall be met on both frontages. On multiple frontage lots that are not corner lots (such as through lots) the RBL shall be met for the primary frontage street designated on the regulating plan.©
c. Setbacks.
i. Side yard:.
(A) R-3A District: Min. 5 ft. on one side; 13 ft. total of both sides.
(B) R-3B District: Min. 15 ft. on one side, 40 ft. total of both sides.
ii. Rear yard:
(A) R-3A District: Min. 25 ft.
(B) R-3B District: Min. 40 ft.
d. Parking.
i. Driveways, if located in the front and not shared with an adjacent property, shall be located at least 2 ft. from a common lot line. �
ii. If located on a corner lot, driveways shall be at least 40 ft. from any block corner or other driveway.�
iii. Parking is not allowed in a front yard, except on a residential driveway.
e. Principal Building Height.
i. A principal building shall not exceed:
(A) R-3A District: 2 stories.
(B) R-3B District: 1 story.
ii. An attic story configured as habitable space is permitted within the roof area of a building and shall not count against the maximum story height.
iii. Height requirements may be exceeded for certain related structures as specified in Section 13-2.E.
f. Ground Story Height
i. The finished elevation of the ground floor shall not be less than 2 ft. nor more than 5 ft. above the exterior sidewalk, or from the ground elevation, at the front of the building.�
g. Fence Height.
i. A privacy fence, not more than 6 feet in height, is allowed on any portion of the lot that is behind the RBL/building façade and is not otherwise occupied by a building; however, a fence parallel to a lot line shall be either on the lot line or placed at least 2 ft. from the lot line.�
ii. A fence is allowed in a front yard to a maximum height of 40 inches.
h. Garages and Accessory Buildings.
i. One detached garage is permitted, which shall not exceed 16 ft. in height.� ii. A detached garage shall be located in the rear yard and accessed either by an alley or driveway.
iii. Front-facing attached garages:
(A) R-3A District: Permitted, provided they do not project beyond a line located 16 feet behind the façade of the building and do not encompass more than 40% of the total building frontage.
(B) R-3B District: Not permitted.
iv. One accessory storage building is also permitted, which shall not exceed 12 ft.
in height.
v. A detached accessory building shall only be located in the side or rear yard.
An accessory building attached to a principal building shall conform to the regulations applicable to the principal building.
vi. Accessory buildings shall be at least 3 ft. from a side and rear lot line, 10 ft.
from any dwelling, and 6 ft. from any other structure on the lot. �
i. Projections.
i. Except for eaves, awnings, balconies, bay windows, front porches, stoops, and ADA compliant ramps, as specified by this article, no part of a building shall encroach into the RBL or required side or rear setbacks.
ii. Eaves and awnings shall not project more than 2 ft. into the RBL or required side or rear setbacks.�
iii. Porches and stoops. A front porch or stoop is required.�
(A) R-3A District: A stoop may project up to 6 ft. beyond the RBL. Porches are encouraged and may project up to 10 ft. beyond the RBL.
(B) R-3B District: A porch is required for single-family homes and townhouses and may project up to 10 ft. beyond the RBL. A stoop is permitted for
multiple family dwellings and may project 6 ft. beyond the RBL iv. Bay windows may project up to 3 ft. beyond the RBL or required side or rear setbacks.
v. Balconies may project up to 5 ft. beyond the RBL or required side or rear setbacks.
D. Public Buildings.
1. Purpose and Intent. The design of a public building, such as a church, school, congregate child caring facility, or government office is subject to review and approval by the city council after receiving a recommendation from the planning and zoning board. While the intent is to allow flexibility in the design and siting of such unique structures they must also positively contribute to a desired community and neighborhood character.
2. Street Façade. Public buildings may deviate from district RBL and setback requirements when key public amenities, compatible with the character of the surrounding area, have been accommodated, such as a plaza, park, or courtyard.
E. Lots Not Fronting on Existing Streets. Lots (including both existing lots and lots created after the effective date of this ordinance) that do not front onto a street in existence on the effective date of this ordinance shall be developed according to Section 10-7.
Read this code where it is posted (Municode) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.