A. Mixed-use, Commercial, and Residential Buildings. 1. Purpose and Intent. The siting requirements for this district support a compact, mixed-use development pattern for downtown Palmetto and reinforce the significance of public spaces and traditional architectural character. They further emphasize walkable, pedestrian environments that promote a synergy between compatible land uses and strong ties to surrounding residential neighborhoods. 2. Lot Area, Siting, and Height Standards. Specific dimensional requirements for this district are specified as follows: a. Lot Requirements. i. Lot Width — No minimum.$ ii. Lot Area — No minimum. b. Street Façade. i. Horizontal distance to RBL — Min. 0 ft., max. 5 ft.� Residential buildings shall be located between 5 ft. and 10 ft. of the RBL.� ii. A building façade shall occupy at least 80% of the frontage length and shall be built to the RBL within 30 ft. of a block corner.� iii. A street wall shall be required along any frontage that is not otherwise occupied by the principal building. iv. A street wall shall not be less than 4 ft. nor greater than 8 ft. high. v. An outdoor pedestrian area may occupy the frontage not occupied by the building and does not have to be enclosed by a street wall. c. Setbacks. i. Rear yard — A setback of 15 ft. is required, except for lots with access to a rear alley, where no setback is required. ii. Side yard — A setback is not required where a firewall is provided along the side lot line. Where a firewall is not provided, buildings shall be separated by at least 10 ft.© d. Building Height. 1. Height — Min. 2 stories or 20 ft.; max. 3 stories.© ii. An attic story configured as habitable space is permitted within the roof area of a building and shall not count against the max. story height.© iii. Required parapet walls may exceed allowed building heights by 42 in.@ iv. A parapet emphasizing the primary street level building entrance or corner of a building can be an additional 3 ft. high for a distance of 12 ft., or 15% of the facade length, whichever is greater. v. Height requirements may be exceeded for certain related structures as speci-fied in Section 14-2E.@ vi. A detached garage shall not exceed 16 ft. in height. e. Story Height. 1. Mixed Use and Commercial: The ground story finished floor elevation shall be equal to or no more than 18 in. above the exterior sidewalk elevation at the front of the building at the RBL.© ii. Residential: The ground story finished floor elevation shall not be less than 3 ft. nor more than 5 ft. above the exterior sidewalk in front of the building at the RBL.© iil. Mixed Use and Commercial: The ground story shall have a min. interior floor to ceiling height of 15 ft.© iv. Mixed Use and Commercial: All other stories shall have a min. floor to ceiling height of 9 ft. and a max. 12 ft.© v. Residential: The min. interior floor to ceiling height for all stories shall be 9 ft. and a max. 12 ft.© Parking and Loading Standards — C-2 District Property Line Sidewalk Street H Property Line Sidewalk Street f. Parking and Loading. 1. Parking is not allowed forward of the RBL or in any front yard.@ ii. Driveways shall be at least 50 ft. from any block corner.®@ iil. Off-street parking shall be permitted in the rear and side yards behind the RBL when screened by a 4 ft. tall street wall located between the property line and parking lot.© iv. Loading shall be permitted only in the rear yard or within internal loading bays not visible from the street. g. Detached Accessory Structures. i. A detached accessory structure shall be located in the rear yard and accessed either by an alley or driveway. B. Public Buildings. 1. Purpose and Intent. The design of a public or quasi-public building, such as a church, school or government office is subject to review and approval by the city council after receiving a recommendation from the planning and zoning board. While the intent is to allow flexibility in the design and siting of such unique structures they must also positively contribute to a desired community and neighborhood character. 2. Street Façade. Civic/institutional buildings may deviate from district RBL requirements when key public amenities, compatible with the character of the surrounding area, have been accommodated, such as a plaza, park, or courtyard.