--- title: Peachtree City Zoning Ordinance, Sec. 506. Final site plan submittal requirements collection: local-codes id: local-code:peachtree-city/zoning/506 cite_as: Peachtree City, Ga., Zoning Ordinance § 506 canonical_url: https://georgiacommons.org/code/local/peachtree-city/zoning/506 md_url: https://georgiacommons.org/code/local/peachtree-city/zoning/506.md text_url: https://georgiacommons.org/code/local/peachtree-city/zoning/506/text source_url: https://library.municode.com/ga/peachtree_city/codes/code_of_ordinances date: 2026-11-14 status: active jurisdiction: city:peachtree-city jurisdiction_name: Peachtree City place_fips: "1359724" corpus_version: local-codes-peachtree-city-0a3741f04819 publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/code/local/peachtree-city/zoning/~appendix-b/~article-v.md previous: https://georgiacommons.org/code/local/peachtree-city/zoning/505.md next: https://georgiacommons.org/code/local/peachtree-city/zoning/601.md index: https://georgiacommons.org/code/local/peachtree-city.md branch: zoning edition: As published by Municode, retrieved 2026-11-14 edition_date_kind: retrieved source_publisher: Municode version_id: local-code:peachtree-city/zoning/506@2026-11-14-463750a0b3 --- # Peachtree City Zoning Ordinance, Sec. 506. Final site plan submittal requirements > As published by Municode, retrieved 2026-11-14 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Appendix B - LAND DEVELOPMENT ORDINANCE / Article V - PLAT SPECIFICATIONS The applicant shall submit six (6) full size (24" × 36"), one (1) 11" × 17" reduction, and one (1) electronic copy (pdf format) on a CD of the entire submittal package of a final site plan to the city planner, at which time they shall be date stamped as received. A final site plan submittal may consist of one or more sheets. The plans shall be drawn at a reasonable scale on sheets of reasonable size. All plans must be clearly and accurately drawn by a registered design professional licensed to practice in the state, who shall seal and sign each page of the final site plan. At a minimum, the following information shall be provided to initiate the final site plan review process: Site layout plan. (a) Location of all existing and proposed buildings and structures, including dumpster enclosures, with dimensions. Show all roof overhangs, awnings, and other projections. (b) Location of all existing and proposed parking areas, driveways, walkways, cart paths, and other similar hardscape features, with dimensions. (c) Locations of all on-site support facilities like fencing, retaining walls, signage, lighting, mechanical and electrical equipment, and out-of-store marketing devices. (d) Location of all greenbelts, buffers, tree-save areas, specimen trees, berms, retention areas, and other similar landscape features. (e) Location of all parking and building setback areas, with dimensions. (f) Vicinity map. (g) Identification and location of all existing and proposed streets that are adjacent to the property or nearby. Grading plan. (a) Existing on-site topography and proposed new contours at two-foot intervals. (b) Finished floor elevations for all existing and proposed buildings. (c) Significant on-site natural features. (d) Limits of clearing. (e) Tree-save details showing how trees will be protected during construction. (f) Schedule of grading operations. Utilities plan. (a) Location and size of all existing and proposed utility lines from where they connect off-site to their termination on-site. (b) Identification of all valves, hydrants, meters, cleanouts, transformers, and other similar accessory facilities and features. (c) Location and design of any communication towers and/or antennas. (d) Location of tree-save areas relative to the proposed new utility facilities. (e) Installation schedule. Drainage plan. (a) Delineation of drainage basins, including off-site areas that drain onto the project site. (b) Delineation of natural water features, including floodplains, wetlands, lakes, streams, and drainage channels. (c) Drainage system design, including catch basins, culverts, open channels, detention areas, retention ponds, and all other components of the system intended to carry stormwater through and off the site. (d) Installation schedule. Erosion and sedimentation control plan. (a) Plan to be prepared in accordance with the "Manual for Erosion and Sediment Control in Georgia." (b) Erosion control system design, including all facilities necessary to keep material from leaving the construction site, whether it is carried by stormwater, wind, construction vehicles, or other similar means. (c) Proposed grading plan should be used as a base for this plan. (d) Re-vegetation. (e) Implementation schedule. Additional materials. (a) Statement as to whether or not final site plan is in conformance with approved conceptual site plan, and, if not, what the differences are and why the changes were made. (b) Plat of the property. (c) Floor plans for all proposed buildings. (d) Exterior elevations for all buildings and structures, including all support facilities such as signage, lighting, mechanical and electrical equipment, meters, and screening devices. (e) Specifications relative to the exterior elevations, including the materials and colors. (f) Specifications relative to the design of all on-site support and landscape features such as fencing, retaining walls, out-of-store marketing devices, parking areas, driveways, walkways and cart paths. (g) Sign program. (h) Conceptual landscape plan. (i) Specifications relative to site lighting, including the types of fixtures and the intensity levels. (j) Hydrology study, including quantities of runoff generated by the project as compared to pre-development conditions, and design of an acceptable detention system, if required. (k) Water quality impact analysis, including all facilities and features intended to sustain or enhance water quality as a part of the project. (l) Solid waste minimization plan. ## History (Ord. No. 1020, § 1, 1-20-2011)