All exterior lighting should be architecturally compatible with the building style, material, and color selections. Architectural and shoebox style cutoff fixtures shall be used in all parking areas as opposed to cobra type light fixtures and directional floodlights. Exterior lighting of the building and site should be designed so that light is not directed off the site, and the light source is shielded from direct offsite viewing. All outdoor light fixtures should be fully shielded or be designed or provided with light angle cut-offs, so as to eliminate uplighting, spill light, and glare.

Exterior architectural, display and decorative lighting visible from the designated corridors shall be generated from a concealed light source with low-level fixtures. Any lighting fixture used to illuminate parking areas, access drives or loading areas shall be of such design, so as to minimize the amount of ambient lighting perceptible from adjacent properties. In no case shall any lighting impair the vision of motorists on the corridor.

Entrances into developments from the designated corridors may be lighted for traffic safety reasons, provided such lighting does not exceed the applicable footcandle requirements specified below. Excessive illumination of signage, buildings, or site features should be avoided. Roof lighting and down-lighting washing the building walls are strongly discouraged.

731.1. Mounting height.

Fixture mounting height should be appropriate for the project and the setting. The overall height of all lighting within parking lots should not exceed 30 feet in height from finish grade to the top of the light fixture. Lower mounting heights are encouraged where sites are located adjacent to residential areas or other sensitive land uses. Use of low, bollard-type fixtures that are three to four feet in height, are encouraged as pedestrian area lighting.

731.2. Light fixtures.

All exterior light fixtures should utilize a cutoff luminaire whose source is completely concealed with opaque housing and should not be visible from any street. This provision includes light sources mounted poles, as well as architectural display and decorative lighting visible from the corridor. Fixtures should be mounted in such a manner that the cone of light is not directed at any property line of the site. Light-emitting diode (LED) is the preferred option. Otherwise, only incandescent, fluorescent, metal halide, mercury vapor or color corrected high-pressure sodium light may be used. An application type of similar consistent lighting fixtures must be utilized for similar use applications on the site. All exterior lighting on a site shall maintain a consistent color temperature.

731.3. Illumination levels.

All site lighting should be designed so that the level of illumination measured in footcandles (fc) at any one point meets the standards below. The planning commission shall have the discretion to allow limited flexibility as to variations in the minimum and average levels, if the proposed levels are below the following standards. The planning commission shall not allow flexibility for proposed levels which exceed the maximum levels, unless such levels strictly conform to the recommended levels within the IESNA Lighting Handbook.

| | | | | |----|----|----|----| | At property lines including right-of-way | Minimum level | Average level | Maximum level | | At property line abutting a residential use | None | - | 0.5 fc | | At property line abutting a retail use | None | - | 1.0 fc | | At property line abutting an office use | None | - | 1.5 fc | | Off-street parking lots | Minimum level | Average level | Maximum level | | Parking lots | 0.5 fc | 3.0 fc | 6.0 fc | | Walkways and streets | 0.2 fc | 1.0 fc | 2.0 fc | | Landscape and decorative | 0.2 fc | .50 fc | 3.0 fc | | Pedestrian | 0.2 fc | 2.0 fc | 5.0 fc |

Lighting underneath canopies for service stations or similar uses shall be restricted to no more than two 320-watt recessed lighting fixtures (including lenses) mounted flush with the bottom of the canopy on each side of a gasoline pump or other design that meets the standards of this chapter. Lighting for canopies for service stations and other similar uses shall not exceed an average of 12 fc as measured at the ground level at the inside of the outside edge of the canopy. Lighting for ATM machines shall be recessed and mounted flush with the actual canopy above the ATM machine and shall comply with the latest requirements identified within the IESNA Lighting Handbook or established by federal regulations.

Decorative wall packs may be used only at service entrances to buildings and shall not be used to draw attention to the building or provide general building or site lighting. Wall packs on the exterior of a building shall be shielded (full cut-off type bulb or light source not visible from off-site) to direct light downward and be of low wattage (100 watts or lower).

Illumination of all monument signage shall be by an externally located steady light source, which is shielded and directed solely at the sign. The intensity of the light shall not exceed 20 fc at any one point on the sign face. Colored lamps are not permitted.

History

The history line the source prints at the end of the section.

(Ord. No. 884, 5-18-2006; Ord. No. 1251, § 1, 3-19-2026)

Read this code where it is posted (Municode) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.

Version local-code:peachtree-city/zoning/731@2026-11-14-5c93647f24

The assistant can say what this section says in this edition, quoting it and linking to it. It will not apply the law to your situation, and nothing here is legal advice.

Peachtree City Zoning Ordinance, Sec. 731. Building and site lighting | Georgia Commons