--- title: Pearson Zoning Ordinance, 70.4. Requirements for Multi-Family Residential Uses collection: local-codes id: local-code:pearson/zoning/70.4 cite_as: Pearson, Ga., Zoning Ordinance ยง 70.4 canonical_url: https://georgiacommons.org/code/local/pearson/zoning/70.4 md_url: https://georgiacommons.org/code/local/pearson/zoning/70.4.md text_url: https://georgiacommons.org/code/local/pearson/zoning/70.4/text source_url: https://library.municode.com/ga/pearson date: 2015-08-11 status: active jurisdiction: city:pearson jurisdiction_name: Pearson place_fips: "1359808" corpus_version: local-codes-pearson-28d36f6e8614 publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/code/local/pearson/zoning/~appendix-a/~article-vii.md previous: https://georgiacommons.org/code/local/pearson/zoning/70.3.md next: https://georgiacommons.org/code/local/pearson/zoning/70.5.md index: https://georgiacommons.org/code/local/pearson.md branch: zoning edition: As published by Municode, current through 2015-08-11 edition_date_kind: current_through source_publisher: Municode version_id: local-code:pearson/zoning/70.4@2015-08-11-a443561a9a --- # Pearson Zoning Ordinance, 70.4. Requirements for Multi-Family Residential Uses > As published by Municode, current through 2015-08-11 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Appendix A - ZONING / Article VII - REQUIREMENTS BY DISTRICTS (a) Single Building Development. One principal multi-family residential building is permitted on one (1) zoning lot in accordance with the following standards: (1) Minimum Lot Area per Dwelling Unit (Square Feet): Multi-family 2,900 (2) Minimum Lot Width for Dwellings: Multi-family 115 ft. (3) Minimum Front Yard. The front wall of the main structure shall be set back from the right-of-way of the street as follows*: Major Street 40 ft. Collector Street 40 ft. Minor Street 35 ft. *See Section 618 Special Building Setbacks for other requirements. (4) Minimum Side Yard on Street. The side wall of the main structure shall be set back from the right-of-way line of the street as follows: Major Street 20 ft. Collector Street 20 ft. Minor Street 20 ft. (5) Side Yard Not on Street. The side wall of the main structure shall be set back from the adjacent property line as follows: Multi-family Least Dimension 15 ft. Both Sides 35 ft. (6) Rear Yard. The rear wall of the main structure shall be set back from the rear property line as follows: 25 ft. (7) Maximum Height. The maximum height for all uses shall be 35 feet, unless approved by the Pearson Fire Department. (8) Floor Area Ratio. Maximum floor area shall not exceed thirty-five percent (35%) of the zoning lot except as provided for in townhouses. (b) Group Building Development. Two or more principal multiple family residential buildings on one or more contiguous lots are permitted in accordance with the following standards: (1) Lot Size and Setback Requirement: All buildings and structures established as a part of a group building development shall comply with the lot area, size, floor area ratio and setbacks according to zoning. (2) Separation of Buildings: All residential buildings established as part of a group building development shall be not less than twenty (20) feet apart. (3) Street Access: Any building established as a part of a group development which cannot be served from an abutting street shall be made accessible to vehicles by a paved driveway having a roadbed width of not less than twenty (20) feet, exclusive of parking spaces. (4) Buffers: Within the above exterior rear and side setback requirements, a planted buffer shall be required. Property within such buffer areas may be included with the lot area for density lot coverage purposes. (c) Townhouses. Townhouses are permitted provided that: (1) Not more than ten (10) nor fewer than three (3) contiguous townhouses shall be built in a row with approximately the same but staggered front line, except units on corner lots may face either street; (2) Minimum width for the portion of the lot on which the townhouse is to be constructed shall be eighteen (18) feet, but the minimum average width of a group of five (5) or more units shall be twenty (20) feet; (3) Lot area shall average no less than 2,500 square feet, and the minimum of any single lot shall be 2,000 square feet; (4) Separation Requirements. No portion of a townhouse or accessory structure in or related to one group of contiguous townhouses shall be closer than twenty (20) feet to any portion of a townhouse or accessory structure related to another group, or to any building outside the townhouse area; (5) Yards. The nearest point of each building shall be at least twenty (20) feet from the nearest right-of-way line of abutting streets and at least ten (10) feet from all other property lines adjacent to the townhouse complex. Each townhouse shall have on its own lot one rear or side yard, private or reasonably secluded from view from streets and from neigh-boring property. Such yard shall not be used for any accessory building. Front and rear yard setbacks shall be the same as the zone in which such townhouse development is located. (6) Grouped Parking Facilities. Insofar as practicable, off-street parking facilities shall be grouped in bays, either adjacent to streets or in the interior blocks. (7) Open Space. In all townhouse projects where more than ten (10) units are to be constructed, a landscaped common area amounting to at least ten percent (10%) of a single townhouse project area shall be provided on the same or adjacent block. No building, parking, storage or other use shall be made of this open space. (8) Buffers. Within the above exterior rear and side setbacks requirements, planted buffer shall be required. Property within such buffer areas may be included within the lot area for density lot coverage purposes.