--- title: Pierce County Zoning Ordinance, 6-7. Storm water drainage collection: local-codes id: local-code:pierce-county/zoning/6-7 cite_as: Pierce County, Ga., Zoning Ordinance ยง 6-7 canonical_url: https://georgiacommons.org/code/local/pierce-county/zoning/6-7 md_url: https://georgiacommons.org/code/local/pierce-county/zoning/6-7.md text_url: https://georgiacommons.org/code/local/pierce-county/zoning/6-7/text source_url: https://library.municode.com/ga/pierce_county/codes/code_of_ordinances date: 2025-01-07 status: active jurisdiction: county:pierce jurisdiction_name: Pierce County county_fips: "13229" corpus_version: local-codes-pierce-county-9a1de177b369 publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/code/local/pierce-county/zoning/~appendix-b.md previous: https://georgiacommons.org/code/local/pierce-county/zoning/6-6.md next: https://georgiacommons.org/code/local/pierce-county/zoning/6-8.md index: https://georgiacommons.org/code/local/pierce-county.md branch: zoning edition: As published by Municode, current through 2025-01-07 edition_date_kind: current_through source_publisher: Municode version_id: local-code:pierce-county/zoning/6-7@2025-01-07-464383081e --- # Pierce County Zoning Ordinance, 6-7. Storm water drainage > As published by Municode, current through 2025-01-07 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Appendix B - LAND SUBDIVISION ORDINANCE / 6 - MINIMUM IMPROVEMENTS The subdivider shall provide adequate storm water drainage in accordance with these regulations and applicable specifications. Where drainage conditions dictate, open ditches shall be paved. The subdivider shall also provide for adequate drainage of springs or other ground water drainage. The drainage system for a subdivision shall be designed in accordance with sound engineering principles and procedures such that all salable parcels included in the final plat are positively drained. The drainage system shall be designed to accommodate drainage from adjacent lands which naturally drain to or through the lands being subdivided. The drainage system shall be designed to not significantly affect the natural drainage onto adjacent lands unless appropriate easements are obtained by the developer from the owner of such adjacent lands concurring with the proposed drainage design. Evidence of such concurrence shall be submitted to the Zoning Administrator along with the improvement plans and specifications. Drainage facilities that are designed to handle flowing water (for example, culverts and weirs) shall be hydraulically designed to function when subjected to the maximum flow rate that can be expected to occur with a 25-year storm event. Drainage facilities that are designed to handle water accumulations (for example, detention ponds with overflow provisions) shall be designed to accommodate the maximum water level that can be expected to occur with a 25-year storm event. Necessary drainage facilities, including but not limited to culverts, rights-of-way, and easements, may be dedicated to the local government, at no expense to the local government, and at the option of the local government. All drainage systems discharging into any creek, stream, or natural body of water, including but not limited to wetlands as determined by the U.S. Army Corps of Engineers, shall pass through an approved sedimentation or detention pond prior to such discharge. A drainage, sedimentation, and soil erosion plan certified by a professional engineer or registered land surveyor shall be submitted to the Zoning Administrator simultaneous with the preliminary plat, at which time technical design criteria will be established. Said plan shall be consistent with the latest version of Best Management Practices as defined by the Georgia Department of Natural Resources.