The applicant must demonstrate how his/her proposal conforms to all of the "guidelines" numbered 1—8, below. The guidelines listed must be used to satisfy each criterion, or the applicant may propose an alternative approach, as approved by the development authority, that better achieves the intent of the guidelines. Before a development may be approved, the development authority, must make findings that the proposal satisfies the guidelines. 1) Compact development. a) The site layout is compact; and b) Opportunities for shared parking are utilized in the proposal; and c) If the site contains more than one use, the site layout clusters buildings on the site to promote linked trips; d) The provisions of section 6, parking, are met; and/or e) The proposal contains an equally good or superior way to achieve the above criterion. 2) Mixed land use. The combining of land uses should promote easy access among stores and services by pedestrians. a) The proposal is a "mixed-use" development or contributes to a mixed-use district; b) The proposal is designed in such a way that it is well integrated with adjacent land uses. "Integrated" means that uses are within a comfortable walking distance (one-eighth mile) and are connected to each other with direct, convenient and attractive sidewalks and/or pathways; or c) The existing and planned land uses on, or in the vicinity of, the site make it impracticable to meet guideline a) or b); or d) The proposal contains an equally good or superior way to achieve the above criterion. 3) Pedestrian access, safety and comfort. All portions of the development are accessible by a direct, convenient, attractive, safe and comfortable system of pedestrian facilities, and the development provides appropriate pedestrian amenities. The design of buildings supports a safe and attractive pedestrian environment. a) In the mixed use, commercial, or professional building zones, each building, residence, or commercial space shall have at least one primary entrance facing a street, or directly accessed by a sidewalk or plaza within ten feet of the primary entrance; and b) Building entrances in mixed use, commercial, or professional building zones open directly to the outside; every building has at least one entrance that does not require passage through a parking lot or garage to gain access; corner buildings have corner entrances whenever possible; and c) In the mixed use, commercial, or professional building zones windows or window displays are provided along at least 30—60 percent of the portion of the building's facade that is designated commercial or professional; and d) Pedestrian facilities as defined in section 4(d), below, shall connect the development to adjacent land uses and provide connections through the development to the public street right-of-way; e) Parking and vehicle drives shall be located away from building entrances, and not between a building entrance and sidewalks, or plazas; f) Surface parking is oriented behind or to the side of a building when possible; parking shall be accessed from an alley only when it attaches to a commercial street; and parking shall not be located on street corners; g) Landscape buffering is provided between parking lots and all adjacent sidewalks; and/or h) The proposal contains an equally good or superior way to achieve the above criterion. 4) Street connections. The development is part of a connected street system that serves vehicles, pedestrians and bicycles. a) Public or private streets connect the development to adjacent neighborhoods and zoning districts; and b) Public streets are preferred over private streets to accommodate through traffic; and c) The proposal implements all planned street connections, as designated by the regional transportation plan, the DeKalb County comprehensive transportation plan, and the City of Pine Lake comprehensive plan; and d) When street connection(s) is/are not practicable, pedestrian connection(s), are made to and through the development in lieu of planned street connection(s). Pedestrian connections should equal what would be available if they were on a street (i.e., distinct from vehicle lane, minimum clear space, Americans With Disabilities Act accessible, direct rate with minimum interruption, shade by day and light by night, connects to a destination that attracts pedestrian activity (front door of commercial use, public plaza/park, residence, transit stop, true street, etc.); and/or e) The proposal contains an equally good or superior way to achieve the above criterion. 5) Crime prevention and security. The site design, buildings, signs, landscaping, parking and other elements provide a safe environment for customers, employees, occupants and adjacent properties. Crime prevention shall be considered in the site design through application of all of the following guidelines: a) Territoriality. All proposed building entrances, parking areas, pathways and other elements are defined with appropriate features that express ownership (generally, people protect and maintain territory that they feel is their own and have a certain respect for the territory of others). For example, landscaping, fences, pavement treatments, art and signs are some physical ways to express ownership through design. Such features should not conflict with the need for natural surveillance, as described in b); and b) Natural surveillance. The proposed site layout, building and landscape design promote natural surveillance. Physical features and activities should be oriented and designed in ways that maximize the ability to see throughout the site. For example, window placement, the use of front porches or stoops, use of low or see-through walls, and appropriate use of landscaping and lighting can promote natural surveillance. Sight-obscuring shrubs and walls should be avoided (shrubs and walls should not exceed three feet in height, and the lowest hanging branches of trees should not be lower than five feet, exceptions shall be granted for new saplings that have not reached their mature heights), except as necessary for buffering between commercial uses and lower density residential districts, and then shall be minimized; and c) Activity support. The proposed site layout and building design encourage legitimate activity in public spaces. For example, locating outdoor seating in areas that are visible from inside a restaurant helps to discourage crime and supports the activity of dining; and d) Access control. By properly sitting and designing entrances and exits (i.e., in clear view from the store), and through the appropriate use of lighting, signs and/or other features, the proposed plan controls access in ways that discourage crime; and/or e) [Other means of compliance.] The proposal contains an equally good or superior way to achieve the above criterion and guideline(s). 6) Parking and land use efficiency. All of the following methods are used whenever possible to minimize the amount of land developed as surface parking: a) Shared parking. "Shared parking" means that multiple uses share one or more parking facilities. Parking demands must "peak" during different times of the day. i) The minimum number of parking spaces for a mixed use development or where shared parking strategies are proposed shall be determined by a study prepared by the applicant following the procedures of the urban land institute shared parking report, ITE shared parking guidelines, or other approved procedures. A formal parking study may be waived for small developments where there is established experience with the land use mix and its impact is expected to be minimal. The actual number of parking spaces required shall be based on well-recognized sources of parking data such as the ULI or ITE reports. If standard rates are not available or limited, the applicant may collect data at similar sites to establish local parking demand rates. If the shared parking plan assumes use of an existing parking facility, then field surveys shall be conducted to determine actual parking accumulation. If possible, these surveys should consider the seasonal peak period for the combination of land uses involved. ii) If a privately owned parking facility is to serve two or more separate properties, a legal agreement between owners guaranteeing access to, use of, and management of designated spaces is required. For a sample shared parking ordinance, please refer to appendix A: model - shared use agreement for parking facilities. b) Credit for on-street parking. The amount of required off-street parking shall be reduced by one off-street parking space for every on-street parking space adjacent to the development. On-street parking shall follow the established configuration of existing on-street parking, subject to city standards, except that angled parking may be allowed for some streets, as approved by the development authority. The configuration of the on-street parking and allowable credit toward off-street parking requirements shall be addressed during site/design review. The city clerk shall maintain a written record of credits granted per each use; c) Reduce or waive minimum off-street parking standards. The applicant may request a reduction to or waiver of parking standards based on a parking impact study. The study allows the applicant to propose a reduced parking standard based on estimated peak use, reductions due to easy pedestrian accessibility; availability of transit service, and likelihood of car pool use; and adjacent on-street parking. The parking study is subject to review and approval or modification by the development authority; d) Maximum parking ratio. Surface parking shall not exceed 110 percent of the minimum parking requirement for the subject land use(s). Exemptions to the standard can be approved through site/design review for developments that provide parking structures, shared parking, valet parking spaces, market rate parking, or similarly managed parking facilities; e) Structured parking incentive. A density or floor area bonus of one building story may be granted for every full story of structured parking provided below grade in a building. A maximum credit of two stories may be applied, and may not be used to exceed the height restrictions along a public street [section 5, 2) a)], but may be applied to allow an exception to height restrictions set back from the public road frontage, subject to the residential setback height requirements in section 5, 2) c). f) Valet parking. Valet parking is permitted where a valet parking plan is approved by the city with the site/design review application. Valet parking allows stacking of smaller parking spaces with less space devoted to drive aisles. 7) Creating and protecting public spaces. The proposal provides usable public space, and recognizes and responds appropriately to existing or planned public spaces (e.g., parks, civic buildings and spaces, transit stops, sidewalks, plazas, and similar spaces). Public spaces are "public" when they are within view of a street or other public space, accessible by pedestrians, and can be occupied by people. All developments shall meet or exceed the following guidelines. A development proposal may be required to mitigate impacts to a public space when it is likely to degrade public safety, or the function, comfort or attractiveness of a public space. a) The development provides at least 20 square feet of public space, in addition to required sidewalk(s), for every ten off-street surface parking spaces or 1,000 square feet of ground-floor space, whichever is greater. b) The development does not diminish the safety, function, comfort or attraction of an existing public space, as described in 1—4, below. A superior design may enhance an existing public space and/or create a superior public space(s). 1) "Safety" means both pedestrian safety near vehicles, and safety related to crime prevention (see number 5, above); and 2) The "function" of a public space may include transportation, in the case of the sidewalk; recreation and socialization, in the case of a plaza or park; and 3) "Comfort" means the ability of a public space to reasonably accommodate expected uses; and 4) "Attraction" relates to the reason people use the public space; and/or c) The proposal contains an equally good or superior way to achieve the above criterion. 8) Human scaled building design. Building facades are designed to a human-scale, for aesthetic appeal, pedestrian comfort, and compatibility with the design character of the district or neighborhood. Building design standards should be tailored to fit the local design context and character. Proposed development should consider the following guidelines: a) Existing architectural character of the neighborhood/district, which may or may not be an appropriate guide for new development or redevelopment; design reflects the context of its surroundings or create its own distinct look and identity; b) Continuity of the building sizes; c) How the street-level and upper-level architectural detailing is treated; d) Roof forms; e) Rhythm of windows and doors; and f) General relationship of buildings to public spaces such as streets, plazas, other open space and public parking.