--- title: Pooler Code of Ordinances, Sec. 50-94. Building standards for areas of special flood hazard (AE-zones) with established base flood elevations and without designated floodway collection: local-codes id: local-code:pooler/code/50-94 cite_as: Pooler, Ga., Code of Ordinances § 50-94 canonical_url: https://georgiacommons.org/code/local/pooler/code/50-94 md_url: https://georgiacommons.org/code/local/pooler/code/50-94.md text_url: https://georgiacommons.org/code/local/pooler/code/50-94/text source_url: https://library.municode.com/ga/pooler date: 2026-11-11 status: active jurisdiction: city:pooler jurisdiction_name: Pooler place_fips: "1362104" corpus_version: local-codes-pooler-3020d91f8764 publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/code/local/pooler/code/~part-ii/~chapter-50/~article-ii/~division-3.md previous: https://georgiacommons.org/code/local/pooler/code/50-93.md next: https://georgiacommons.org/code/local/pooler/code/50-95.md index: https://georgiacommons.org/code/local/pooler.md branch: code edition: As published by Municode, retrieved 2026-11-11 edition_date_kind: retrieved source_publisher: Municode version_id: local-code:pooler/code/50-94@2026-11-11-d9aa0efbb0 --- # Pooler Code of Ordinances, Sec. 50-94. Building standards for areas of special flood hazard (AE-zones) with established base flood elevations and without designated floodway > As published by Municode, retrieved 2026-11-11 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Part II - CODE OF ORDINANCES / Chapter 50 - FLOODS / Article II - FLOOD DAMAGE PREVENTION / Division 3 - PROVISIONS FOR FLOOD HAZARD REDUCTION Located within the areas of special flood hazard established in section 50-36, where streams with base flood elevations are provided but no floodway has been designated, (AE-zones), the following provisions apply: (1) No encroachments, including fill material, new structures or substantial improvements shall be located within areas of special flood hazard, unless: a. Any fill material or portion of any other improvement placed inside a special flood hazard area (SFHA) below base flood elevation shall be mitigated on site or on an adjacent site by an equal to or greater volume of excavated material. The mitigation excavation must be connected to the SFHA at an elevation less than or equal to an elevation two feet below the 100-year flood plain elevation or the stormwater conveyance system shall be sized and constructed to convey the 100-year 24-hour storm to a suitable outfall. If subsection (a) above is unable to be met, subsection (b) shall apply. b. Certification by a registered professional engineer is provided demonstrating that the cumulative effect of the proposed development, when combined with all other existing and anticipated development, will not increase the water surface elevation of the base flood at any point within the community. The engineering certification should be supported by verifiable technical data that conforms to standard hydraulic engineering principles. (2) New construction and substantial improvements shall be elevated or flood-proofed to elevations established in accordance with section 50-92. ## History (Ord. No. O2025-01.A, § III, 3-18-2025; Ord. No. O2025-06.D, § II, 7-21-2025) ## Meetings that refer to this section Found 1: meetings of this government whose minutes or machine transcripts name this section, or an ordinance in its history line, newest first. Found by rule from those records' own words. A reference is a pointer to another record, not a statement that the section applies or was changed. - 2025-02-18: [Pooler City Council work session minutes, February 18, 2025](https://georgiacommons.org/meetings/2025-02-18/pooler-city-council-work-session.md) (minutes) refers to this section: "SECTION 50-94"