--- title: Putnam County Zoning Ordinance, Sec. 28-67. Design standards for streets collection: local-codes id: local-code:putnam-county/zoning/28-67 cite_as: Putnam County, Ga., Zoning Ordinance ยง 28-67 canonical_url: https://georgiacommons.org/code/local/putnam-county/zoning/28-67 md_url: https://georgiacommons.org/code/local/putnam-county/zoning/28-67.md text_url: https://georgiacommons.org/code/local/putnam-county/zoning/28-67/text source_url: https://library.municode.com/ga/putnam_county/codes/code_of_ordinances date: 2026-02-17 status: active jurisdiction: county:putnam jurisdiction_name: Putnam County county_fips: "13237" corpus_version: local-codes-putnam-county-e5ae5a3ca944 publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/code/local/putnam-county/zoning/~part-ii/~chapter-28/~article-iii/~division-1.md previous: https://georgiacommons.org/code/local/putnam-county/zoning/28-66.md next: https://georgiacommons.org/code/local/putnam-county/zoning/28-68-to-28-74.md index: https://georgiacommons.org/code/local/putnam-county.md branch: zoning edition: As published by Municode, current through 2026-02-17 edition_date_kind: current_through source_publisher: Municode version_id: local-code:putnam-county/zoning/28-67@2026-02-17-59a04a948b --- # Putnam County Zoning Ordinance, Sec. 28-67. Design standards for streets > As published by Municode, current through 2026-02-17 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Part II - CODE OF ORDINANCES / Chapter 28 - DEVELOPMENT REGULATIONS / Article III - DESIGN STANDARDS / Division 1 - INFRASTRUCTURE REQUIREMENTS In order to provide for roads suitable in location, width and improvement, and to coordinate roads so as to compose a convenient system and avoid undue hardships to adjoining properties, the following design standards for roads are hereby required and shall be planned for and provided by the developer. Road classifications may be indicated in the comprehensive plan; otherwise, they shall be determined by the director. The developer shall dedicate and/or deed the required right-of-way to the county at no cost to the county. (a) Rights-of-way. (1) Minimum street right-of-way widths shall be as follows: a. County arterial street: 80 feet. b. County collector street: 60 feet. c. Local street: 60 feet. d. Alleys: 24 feet. (b) Pavement widths. Street pavement widths shall be provided as follows: (1) County arterial street (two lanes not divided): 26 feet without curb and gutter or 24 feet with curb and gutter, 27โ€”28 feet back-to-back. (2) County collector street: 26 feet without curb and gutter or 24 feet with curb and gutter, 27โ€”28 feet back-to-back. (3) Local street: 22 feet with or without curb and gutter and 25โ€”26 feet back-to-back. (4) Alleys: 18 feet (residential); 20 feet (commercial and industrial). (c) Ingress/egress: A minimum of two vehicular ingress/egress points shall be required if the development proposes more than 100 dwelling units. (d) Paving requirements: subgrade. These generally are requirements of subdivisions; however, whenever an existing street is required by this chapter to be widened or decel and turn lanes provided, regardless of the type of development, these standards shall apply. Accel/decel lanes shall meet these requirements or match existing whichever is thickest. (1) Clearing and grubbing right-of-way. This work shall consist of removing and disposing of all vegetation and debris within the right-of-way to a depth of at least three feet below the existing grade for any fill sections and three feet below finished subgrade for any cut sections. Topsoil shall be stripped and stockpiled for later use. All stump holes shall be backfilled and compacted to 95 percent of the Standard Proctor density with a suitable material, Class I or II Soil. (2) Subgrade. This work shall consist of placing, mixing, compacting and shaping the top 24 inches of soil. This work also includes subgrade stabilization. (3) Compaction. The entire surface shall be plowed, harrowed and mixed to a depth of at least six inches. After the material has been thoroughly mixed, the subgrade shall be compacted at 98 percent of the Standard Proctor density. The appropriate roller for the soil to be compacted shall be used. Compaction tests shall be made by a certified engineer or from a certified laboratory. Tests are to be made along the roadbed at 500-foot intervals and at every two feet of fill. Any areas that do not meet with the specified compaction shall be excavated and replaced with suitable material. Test results shall be submitted to the director. The developer shall incur all costs for compaction tests. In addition, proofrolling of the area shall be required consisting of a ten-ton payload on a standard tandem axle dump truck or other mutually agreed upon piece of loaded machinery, which shall be done in the presence of the public works department representative. (4) Subgrade material. All streets shall consist of Class I or II soil. If such material is not available on-site, it shall be furnished by the developer. (e) Paving requirements: base. (1) Local streets shall have an eight-inch compacted graded aggregate base (GAB) at 98 percent of the Standard Proctor density. (2) County arterial and collectors shall have an eight-inch crusher run stone base or a four-inch compacted graded aggregate base (GAB) compacted to 100 percent of the Standard Proctor density. (3) Compaction testing intervals shall be required as prescribed in subsection 28-67(d)(3). Proof-rolling may also be required per the same paragraph. (f) Paving requirements: prime. All roadways shall be primed in accordance with the requirements of the Department of Transportation Standard Specifications, Construction of Roads and Bridges, Section 412, Bituminous Prime. (g) Paving: wearing surface. (1) Local streets (includes residential/subdivision streets). A two-inch plant mix asphalt type E or F top-wearing surface is to be applied over the eight-inch base. (2) Arterial and collector roads. The minimum paving design for these roads shall be compacted subbase at 98 percent of the Standard Proctor density, an eight-inch graded aggregate base, two inches of type B binder, and one and one-half inches of type E or F top-wearing course. (3) Driveway turnouts/curb cuts. These shall be paved in accordance with the applicable receiving street/road and shall have a minimum radius of 15 feet. Suitable concrete paving is also acceptable for turnouts or curb cuts. Turnout/ curb cuts serving single driveways shall have a minimum width after radius of 12 feet with commercial/industrial turnouts/curb cuts meeting requirements of subsection 28-65(h). (4) Commercial/Industrial entrance and lots. Due to the Americans with Disabilities Act, any and all ingress, egress, and parking lots/area including internal roads to and from, shall be paved by suitable conventional asphalt paving or concrete paving. (h) Shoulder requirements. The street right-of-way shall be graded to provide at least a five-foot gently sloping strip (sloped at approximately two percent away from the road) measured from the back of the curb or edge of the pavement on both sides of the street to provide utilities, to prevent the encroachment of driveways into the street surface, and to provide, however, that eight feet shall be provided for walkways off the paved vehicular surface; provided, however, that the director of the planning and development department may waive this requirement in cases where the subdivider can demonstrate that the topography of the land being subdivided is such that compliance with this section would be impractical. Topsoil, striped and stockpiled before paving, shall be spread at a minimum depth of four inches in preparation of the seedbed. The soil shall be thoroughly broken, well pulverized, smoothed and firm before planting. The shoulder shall be seeded with tall fescue and Bermuda applied at a rate of 40 pounds per acre. Mulch shall be used on all seeded areas. The mulch material may consist of rye, oat or wheat straw of good quality, free of seeds of competing species. (i) Culverts. Pipe size shall be determined by standard engineering practices but in no case be sized to handle less than a 25-year post-developed storm event nor shall the time of concentration be less than five minutes for any predeveloped flow calculations. All cross drainpipes for multifamily driveways shall be fully bituminouscoated corrugated metal pipe with the appropriate bedding, inlet/outlet protection, and headwalls/flared-end sections. Installations shall be in accordance with state DOT standards. A hydrology study with pre- and post-development flows and routing computations shall be submitted with the design. Pipe gauge (thickness) shall be as determined by the height of the fill. Minimum cover pipes shall be 12 inches. HDPE (hydro polyethylene) pipe with smooth inside lining may be substituted for the CMP (corrugated metal pipe) if adequate cover can be achieved in accordance with manufacturer specifications. Reinforced concrete (RC) pipe is required under county arterials and county collectors and local streets. Multibarrel culverts are permitted if single barrel pipe installations cannot adequately provide the flow capacity and achieve cover over the pipe. (j) Design standards for cul-de-sacs. Except where topographic or other conditions make a greater length unavoidable, as determined by the director, cul-de-sacs (dead-end streets) should not be greater than 1,200 feet in length measured from the nearest (existing or proposed) intersection. It is recommended that they be not greater than 500 feet in length in multifamily areas. They shall be provided at the closed end with a turnaround having a property line radius of at 70-foot radius with an outside pavement radius of at least 50 feet. Temporary paved turnarounds are required at the end of any roadway of each phase until the next phase of the development is initiated. ## History (Res. of 7-17-2007(2); Ord. of 6-25-2024(1))