Richmond Hill · Zoning Ordinance
Appendix A - ZONING / Article III - GENERAL PROVISIONS
Section 6. Buffers.
About this text
- As published by Municode, retrieved 2026-11-11
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
(A) Determination of buffer requirements between residential, commercial, industrial and other zones. When two adjoining properties are in dissimilar residential, commercial, industrial, or other zone districts, the property within the zone district allowing more intensive uses is required to provide the buffer when acquiring a building permit unless the buffer is preexisting and deemed adequate by the city planning commission. All such buffers shall fully meet the buffer requirements shown in Table III. 6.1, "Buffer Requirements Between Dissimilar Zones." The codes shown on Table III. 6.1 are defined below. When two adjoining vacant parcels are in dissimilar zone districts, no buffer is required when the parcel zoned for less intensive use acquires a building permit. The following requirements do not include drainage ditches, easements or rights-of-way.
1.1. Buffer requirement. The required buffer shall consist of plantings or a fence, a wall (not otherwise part of a structure or accessory structure), or a berm, which meets the screening standards of subsection (B), this section. If plantings are chosen method of screening, the planting area shall have a minimum base width of 12 feet.
1.2. Buffer requirement. The required buffer shall have not less than a 20-foot base width and shall consist of plantings plus a fence, a wall (not otherwise part of a structure or accessory structure), or a berm, or any combination thereof, which meets the screening standards of subsection (B), this section.
1.3. Buffer requirement. The required buffer shall consist of a 50-foot setback from the adjoining property line containing not less than a 20-foot base width consisting of plantings plus a fence, a wall (not otherwise part of a structure or accessory structure), or a berm or any combination thereof, which meets the screening standards of subsection (B), this section.
1.4. Buffer requirement. The required buffer shall consist of a 100-foot setback from the adjoining property line containing not less than a 20-foot base width consisting of planting plus a fence, a wall (not otherwise part of a structure or accessory structure), or a berm, or any combination thereof, which meets the screening standards of subsection (B), this section.
1.5. Buffer requirement. The required buffer shall consist of a 200-foot setback from the adjoining property line containing not less than a minimum 75-foot base width consisting of plantings plus a fence, a wall (not otherwise part of a structure or accessory structure) or a berm or any combination thereof, which meets the screening standards of subsection (B), this section. The 75-foot vegetated buffer shall be immediately adjacent to the property line. This buffer shall extend along and be contiguous with the entire property line between the dissimilar uses, abutting the commercial or industrial facilities plus 100 feet in each direction beyond the facilities.
(B) Screening standards. Screening is a method of visually shielding or obscuring one use from another by fences, walls, berms or densely planted vegetation.
(1) Plantings. Plantings shall consist of either trees or shrubs or any combination of both.
Planted areas shall be located along the abutting property lines or in areas that will provide the best screening effectiveness.
(a) If trees or large shrubs are used solely as the screening devise, they shall be any evergreen species from the list provided by the zoning administrator which, under normal growing conditions, will attain a minimum height of eight feet and a canopy spread of ten feet within four years. They shall be planted a minimum of 20 feet on center.
(b) If trees are used in combination with shrubs, they may be of any species from the list provided by the zoning administrator. Small trees shall be planted 30 feet on center, and large trees 40 feet on center. Shrubs shall be any evergreen species from the list provided by the zoning administrator planted four feet on center.
Shrubs shall initially be of any size, which would normally attain a minimum height of six feet within three years after planting.
(2) Walls. Walls shall be constructed in durable fashion of masonry materials and be a minimum height of eight feet. The wall shall be placed on the edge of the buffer nearest the most intense land use.
(3) Fences. Fences shall be a minimum of eight feet in height and constructed in a durable fashion of standard pressure treated wood fencing materials (but not woven wooden fences) and methods that will provide 90 percent visual blockage. The fence shall be placed on the edge of the buffer nearest the most intense land use and the finish side of the fence shall face the abutting property.
(4) Berms. Earthen berms shall have a minimum height of eight feet with a maximum slope of 4:1 as measured from the exterior property line. Berms shall be stabilized to prevent erosion and shall be landscaped.
(5) Buffers between residential areas and Interstate 95. Residential developments which are located along or adjacent to Interstate 95 must be buffered from the Interstate 95 traffic noise. A masonry wall will be built between the residential area and Interstate
95. The height of the wall will not be less than 20 feet above the grade of the Interstate 95 highway. The city planning commission must approve any such buffer wall.
Additionally, any such buffer wall must be landscaped on the residential side with plantings that screen the wall from residential view.
(C) Buffer design. All buffers required by this article shall conform to the following specifications:
(1) Prior to development, a buffer plan shall be required to show the types and locations of all plantings within a required buffer. If a site plan is required, a buffer plan shall be incorporated as part of the site development plan.
(2) Landscaping within buffer areas shall be used to screen objectionable views or nuisances, such as parking and service areas, refuse containers, air conditioning units and transformers.
(3) Existing on site trees may be credited as meeting the requirements of this article if the building inspector determines that such plant materials achieve the purposes of this article.
(D) Location of buffers. Buffers shall be located on the outer perimeter of a lot or parcel along all lot lines adjoining dissimilar zones including adjacent property lines, which may be separated by an existing or proposed public right-of-way. Buffers shall not be located on any portion of existing, dedicated, or reserved public or private street right-of-way.
(E) Variances. The requirements of this article may be waived by the appropriate agency under any of the following conditions:
(1) If it is clearly demonstrated that the existing topography and/or vegetation will achieve the purposes of this article.
(2) If it is clearly demonstrated that for topographic reasons, no required screening device could possibly screen the ground level activities of the use from the first floor view of the residential structure abutting the use.
(3) The adjoining property owners mutually agree in writing that the required buffer is not necessary for a satisfactory use and enjoyment of their property rights, and such agreement is made and recorded as a covenant running with each parcel or parcels of land.
(4) It is clearly demonstrated that an existing (or proposed) public right-of-way separation between adjoining properties will achieve the purposes of this article.
(F) Use of buffers. A buffer may be used for some forms of passive recreation such as pedestrian, bike, or equestrian trails, or as a storm water retention area provided that: 1) no planted materials shall be eliminated; and 2) the total width of the required buffer area shall be maintained.
(G) Maintenance. The responsibility for maintenance of buffers shall remain with the owner of the property. Any required plant that has died shall be replaced. Maintenance of planted areas shall consist of mowing, removal of litter and dead plant materials, and necessary pruning. Fences and walls shall be kept in a condition that meets the requirements of this article.
(H) Failure to comply with these provisions. See article VII, section 13 of this ordinance for enforcement and penalty provisions.
(I) Surety for buffer installation. When the date for issuing a certificate of occupancy does not coincide with the planting conditions that are necessary to install a required buffer, the zoning administrator shall accept a letter of credit or other acceptable surety for the buffer installation. Such surety shall be in the amount and form satisfactory to the zoning administrator and shall certify the following:
(1) That the creditor does guarantee funds in an amount to cover the cost of the installation of all buffers as estimated and approved by the zoning administrator.
(2) That in case of failure of the developer to complete the specified improvements, the creditor shall pay the government immediately, and without further action, such funds as are necessary to finance the completion of those improvements up to the limit of the secured credit; and
(3) That the letter of credit or other surety may not be withdrawn or reduced in amount until released by the zoning administrator after final inspection and certification or approval of the buffer.
(J) Notice to purchasers. When any lot within the city that requires a buffer under this section is conveyed to the initial purchaser by the developer, the developer shall include in the deed or other instrument of conveyance a covenant, running with the land, making the conveyance subject to the provisions of subsections (F), (G) and (H) of this section.
History
(Ord. of 10-17-00, § C.1—3)
Read this code where it is posted (Municode) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.