--- title: Rockdale County Zoning Ordinance, Sec. 214-14. Architectural design standards collection: local-codes id: local-code:rockdale-county/zoning/214-14 cite_as: Rockdale County, Ga., Zoning Ordinance § 214-14 canonical_url: https://georgiacommons.org/code/local/rockdale-county/zoning/214-14 md_url: https://georgiacommons.org/code/local/rockdale-county/zoning/214-14.md text_url: https://georgiacommons.org/code/local/rockdale-county/zoning/214-14/text source_url: https://library.municode.com/ga/rockdale_county/codes/code_of_ordinances date: 2026-01-27 status: active jurisdiction: county:rockdale jurisdiction_name: Rockdale County county_fips: "13247" corpus_version: local-codes-rockdale-county-c3e0b855bd42 publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/code/local/rockdale-county/zoning/~part-ii/~part-b/~title-2/~chapter-214.md previous: https://georgiacommons.org/code/local/rockdale-county/zoning/214-13.md next: https://georgiacommons.org/code/local/rockdale-county/zoning/218-1.md index: https://georgiacommons.org/code/local/rockdale-county.md branch: zoning edition: As published by Municode, current through 2026-01-27 edition_date_kind: current_through source_publisher: Municode version_id: local-code:rockdale-county/zoning/214-14@2026-01-27-431f0e3ffe --- # Rockdale County Zoning Ordinance, Sec. 214-14. Architectural design standards > As published by Municode, current through 2026-01-27 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Part II - CODE OF ORDINANCES / Part B - PLANNING AND DEVELOPMENT / Title 2 - LAND USE AND ZONING / Chapter 214 - STANDARDS APPLYING TO ALL DISTRICTS (a) Applicability. (1) The architectural standards established by this section shall apply to all zoning districts where residential uses are permitted. (2) As related to manufactured homes, these standards shall apply to all Class A, Class B, and Class C manufactured homes, as defined by this UDO. (3) Where any provision of this section conflicts with a standard or requirement expressly stated within a zoning or overlay district, the standard or requirement of the district shall control. The provisions of this section are intended to be supplementary to, and not in lieu of, applicable zoning district standards unless otherwise expressly stated. (b) Architectural design standards for multifamily residential buildings. (1) Design composition. a. Building designs shall incorporate a composition of features. Features include, but are not limited to, columns, windows, doors, balconies, pilasters, changing rooflines, plan offsets, cornice, porch entrances, tower elements, architectural patterns and texture, cupolas, and dormers. The maximum wall length without façade features shall not exceed 50 feet along street-facing façades. b. The appearance and materials of the rear and side walls shall be similar to and compatible with the front of the building. c. Building entrances shall be wellmarked and identifiable from the building form. d. Common walls and common floors ceiling between units shall be constructed to meet a sound transmission coefficient (STC) rating of 50 or higher. e. Building designs with greater than three stories shall incorporate at least one significant color change, material change, or architectural feature on either the lower story or upper story. This requirement shall not apply to corner elements, entrance features, or other architectural projections, provided such features are clearly designed to emphasize building entrances or articulate a special architectural volume. f. Exterior burglar bars and steel rolldown curtains are prohibited. g. Ground mounted electrical, mechanical, and like utility equipment shall be screened. Screening height shall be equal to the height of the equipment. Screening shall not resemble mechanical louvers. h. Wall mounted electrical, mechanical, utility meters, and other utility equipment shall be screened. Screening height shall be equal to the height of the equipment. Screening shall not resemble mechanical louvers. i. All roof mounted equipment, such as mechanical units, vent hoods, communication devices, and/or other building system(s) equipment, shall be screened from view on all sides of the building. Roof screening height shall be equal to the height of the equipment. Screening shall not resemble mechanical louvers. (2) Additional requirements applicable to multi-family residential buildings. a. Utility equipment and service meters are to be located away from high visibility and usage areas and effectively screened from view. The use of enclosed structures or interior access to utility equipment and meters is encouraged. The use of utility closets on exterior walls is prohibited. b. All roof vents, pipes, antennas, satellite dishes, and other roof equipment (except chimneys) shall be located on the rear elevations and, except for satellite dishes, be painted to match the color of the roof or, if technical considerations prevent installing satellite dishes on the rear elevation, then such equipment shall be installed where it will have minimal visual impact as seen from the street. c. Trash enclosures in amenity areas shall be screened from view on at least three sides by a solid wall or fence of at least six feet in height, and on the fourth side by a solid gate no less than five feet in height. (c) Architectural design standards for attached and detached residential buildings. (1) Design composition. a. Building designs shall incorporate a composition of features. Features include, but are not limited to, columns, architectural windows, balconies, pilasters, changing rooflines, cornice, ornamental roof brackets, porch entrances, tower elements, material patterns, cupolas, and dormers. b. Ground mounted electrical, mechanical, and like utility equipment shall be screened. Screening height shall be equal to the height of the equipment. c. Wall mounted electrical, mechanical, utility meters, and other utility equipment shall be screened. Screening height shall be equal to the height of the equipment. d. All roof mounted equipment, such as mechanical units, vent hoods, communication devices, and/or other building system(s) equipment, shall be screened from view on all sides of the building. Roof screening height shall be equal to the height of the equipment. e. Garages on detached residential uses: 1. Front-facing garage doors shall not take up more than 40 percent of the linear width of any street-facing façade. 2. Front-facing garage doors shall be offset from the front façade by a minimum of five feet. This offset may be achieved through conditioned interior space or a porch. f. Garage doors on any residential building shall incorporate fenestration, decorative hardware, or other architectural detailing. Alternative treatments may be approved by the director of planning and development if they provide equivalent visual interest. g. The front façades shall have architectural modulation and detail that includes features such as varied materials and wall planes, varied roof forms and roof lines, balconies, porches, bay windows, varied window sizes and shapes, shutters, entrance doors, sidelights, pilasters, varied garage door designs, and other features to provide visual interest. h. Residential structures along existing public right-of-way shall require any side or rear façade that is visible from the public right-of-way to include the same exterior finish materials and similar landscaping as the front of the structure. In addition, it shall include windows and architectural features similar to the front façade, including, but not limited to, awnings, cornice work, edge detailing, or other decorative finish materials. i. Stoops and porches, where facing streets or open spaces, shall be a minimum of four feet deep. j. All chimneys and fireplace enclosures on the exterior of the façade shall extend to the ground and a minimum of three feet above the roof line. (2) Site requirements. a. Required driveway depths. Driveways shall be constructed to provide sufficient space for a standard passenger vehicle. Vehicles are prohibited from overhanging or obstructing any adjacent sidewalk or the public right-of-way. b. All sidewalks internal to a development shall be least five feet in width and shall be located on both sides of any public or private street. c. Utility requirements. 1. Individual systems for water, fuel/gas, and HVAC shall be required for each unit. 2. Individual metering shall be provided for water, electric, and fuel/gas utilities. 3. Easements for utility lines shall be provided in the common ownership area where lateral service connections shall take place. d. All roof vents, pipes, antennas, satellite dishes, and other roof equipment (except chimneys) shall be located on the rear elevations and except for satellite dishes be painted to match the color of the roof or, if technical considerations prevent installing satellite dishes on the rear elevation, then such equipment shall be installed where it will have minimal visual impact as seen from the street. e. Trash enclosures in amenity areas shall be screened from view on at least three sides by a solid wall or fence of at least six feet in height, and on the fourth side by a solid gate no less than five feet in height. (d) Manufactured homes standards. Any replacement of a pre-existing manufactured home or mobile home with a new manufactured or mobile home shall be permitted in accordance with O.C.G.A. § 36-66-7 et seq. Furthermore, an existing, nonconforming industrialized home that was lawfully permitted prior to the effective date of this unified development ordinance may be replaced with a new manufactured home, notwithstanding the architectural bulk standards herein, provided the replacement is done so within 12 months of the date of removal of the existing mobile home and all conditions and requirements of O.C.G.A. § 36-66-7 et seq are met. ## History (Ord. No. O-2025-23, 9-9-2025)