Sec. 214-7. Exterior building materials.
About this text
- As published by Municode, current through 2026-01-27
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
(a) In nonresidential zoning districts, sheet metal, vinyl siding, exposed common concrete block and similar materials shall not be permitted as exterior materials on sides of buildings facing any road. The exterior materials of the face of said buildings on the sides facing a road shall consist of glass, brick, stone, architectural concrete block, real stucco or similar building materials.
(b) In residential zoning districts, sheet metal, vinyl siding, exposed common concrete block and similar materials shall not be permitted as exterior building materials on principal use structures except that soffits, gables and eaves may be finished in vinyl. Refer to section 218-7 accessory use standards for allowable exterior materials on accessory structures in residential zoning districts.
(c) Attached and detached single-family and manufactured home building exterior finish materials.
(1) Exterior building materials shall be primarily brick, stone, other masonry,
glass, wood, or cementitious fiberboard.
Vinyl shall be prohibited except for window frames (head, sill, jambs).
(2) All exposed foundation walls, including a water table between 18 and 24 inches
above finished grade on all sides of the building, shall be faced with brick, stone, or other masonry material. Where grade
slopes toward a basement condition, the brick or stone water table shall extend along the sides and rear of the home to match the height established on the front façade.
(3) All brick, stone, or other masonry shall be full- or half-depth. Simulated veneer panels are prohibited. Simulated masonry that are individually stacked or applied are acceptable.
(4) Metal shall be permitted only as standing seam metal roofing or as an architectural accent comprising a
maximum of ten percent of any one façade.
Acceptable metal materials are limited to architectural metal panels, architectural metal cladding, metal mesh, and perforated metal. Examples of metal
materials not permitted include but are not limited to stock PEMB metal skins commonly referred to as 'R-panel' and sheet metal systems with exposed fasteners, except as required for perforated metal.
(5) Concrete masonry units are prohibited.
(6) Industrial metal siding is prohibited.
(7) Exposed plywood/OSB/pressed wood sheathing is prohibited.
(8) Exposed neon, LED or other types of exposed bulb accent lighting is prohibited.
(9) Equipment screens for ground mounted units shall have a finish that is consistent with the finish materials of the building façade or provide vegetative landscape
screening immediately around the units.
Screening shall not resemble mechanical louvers.
(10) Equipment screens for wall mounted units shall have finishes that is consistent
with the finish materials of the building façade, or vegetative landscape screening shall be provided immediately in front of the equipment units. Screening
shall not resemble mechanical louvers.
(11) Equipment screens for roof mounted units and appliances shall be a material
consistent with the finish materials of the building façades. Screening shall not resemble mechanical louvers.
(12) Exterior color requirements.
a. No more than three different exterior finish materials or applied wall colors
may be used on any single building elevation. Additional colors or materials may be used for architectural elements such as balconies, foundations, decks, doors, patios, porches, and windows, and shall not count toward the maximum.
b. Bright or fluorescent colors are prohibited.
(13) As related to manufactured homes, these standards shall apply to all Class A,
Class B, and Class C manufactured homes, as defined by this UDO.
(d) Multifamily residential building exterior finish materials.
(1) Exterior building materials shall be primarily brick, stone, other masonry,
glass, wood, or cementitious fiberboard.
Vinyl shall be prohibited except for window frames (head, sill, jambs).
(2) Building walls shall incorporate brick, cast stone, and/or stone for at least 30 percent of the nonfenestration façade
area in the first and second story. Exposed basement walls shall be considered part
of the first story.
(3) All brick, stone, or other masonry shall be full- or half-depth. Simulated veneer panels are prohibited. Simulated masonry that are individually stacked or applied are acceptable.
(4) Metal shall be permitted only as standing seam metal roofing or as an architectural accent comprising a
maximum of 20 percent of any one façade.
Acceptable metal materials are limited to architectural metal panels, architectural metal cladding, metal mesh, and perforated metal. Examples of metal
materials not permitted include but are not limited to stock PEMB metal skins commonly referred to as 'R-panel' and sheet metal systems with exposed fasteners, except as required for perforated metal.
(5) Exposed concrete masonry units are prohibited.
(6) Exposed plywood/OSB/pressed wood sheathing is prohibited.
(7) Exposed neon, LED, or other types of exposed bulb accent lighting shall be
prohibited, unless otherwise authorized by this UDO.
(8) Equipment screens for ground mounted units shall have a finish that is consistent with the finish materials of the building façade or provide vegetative landscape
screening immediately around the units.
Screening shall not resemble mechanical louvers.
(9) Equipment screens for wall mounted units shall have finish that is consistent with the finish materials of the building façade, or vegetative landscape screening shall
be provided immediately in front of the equipment units. Screening shall not resemble mechanical louvers.
(10) Equipment screens for roof mounted units and appliances shall be a material
consistent with the finish materials of the building façades. Screening shall not resemble mechanical louvers.
(11) Exterior color requirements.
a. No more than three different exterior finish materials or applied wall colors
may be used on any single building elevation. Additional colors or materials may be used for architectural elements such as balconies, foundations, decks, doors, patios, porches, and windows, and shall not count toward the maximum.
b. Bright or fluorescent colors are prohibited.
(e) Where any requirement of this section conflicts with a standard or requirement expressly stated within a specific zoning or overlay district, the standard or requirement of the district shall govern. These provisions are intended to supplement, and not supersede, the applicable standards of the underlying zoning district unless otherwise expressly stated.
(Ord. No. 0-2006-32, §§ 1—3, 11-28-2006; Ord.
No. 0-2007-14, § 4, 7-24-2007; Ord. No. 0-2013- 12, § II, 11-12-2013; Ord. No. O-2025-23, 9-9- 2025)