Gate installation shall conform to the following provisions: (a) All gate entrance design installations must be approved by the director of general services and engineering and the director of emergency services prior to installation. The installation must be completed and approved prior to the recording of the final plat of the development. (b) Gate design may incorporate one or two gate sections to meet the required minimum gate width of 24 feet. If the entrance will incorporate a median, guard shack or similar structure that results in a divided gate arrangement, the individual gate widths may be reduced if approved by the director, but in no case shall any one-way travel lane have an unimpeded opening of less than 12 feet. (c) Approach and departure areas on both sides of the gated entrance shall provide adequate setbacks and proper alignment to allow free and unimpeded passage of emergency vehicles through the entrance area. All entry gates must be setback a minimum of 100 feet from any adjacent public street right-of-way to allow for vehicle stacking out of the public travel lanes. (d) Automatic gate installations shall conform to the design and performance guidelines approved by the director of general services and engineering and the director of emergency services. (e) All components of the gate system shall be maintained in an approved operating condition, with all components serviced and maintained on a regular basis as needed to insure proper gate operation. A proper power supply shall be maintained to all electrical and electronic components at all times. In instances of power failure the security gate shall default to an open position to allow access into the property(s). Each security gate regulated under this section shall be subject to a performance test as determined by the director of emergency services. Upon failure of a performance test, the security gate system shall be disabled and maintained in the open position until repaired, and shall not be placed back in service until tested and authorized by the director of emergency services. (f) All streets, gates, signage, equipment and other improvements in the vicinity of the access gate(s) may be subject to periodic inspection by county agents and or employees to ensure necessary emergency access and repaired immediately by the homeowner's association if found to be in a condition of disrepair so as to restore such emergency access. The county agents and or employees shall have the right to enter the subdivision and disable, open or remove any gate, device or other feature that impedes or controls vehicle access at the sole expense of the homeowner's association. Emergency repairs shall be assessed against the homeowner's association. (g) The record title owner of the private street parcel as defined in section 302-7 4 shall be responsible for and liable for any violations of this section. (h) The homeowners association shall coordinate with the United States Postal Service for mail delivery, the school board for school bus service, and local providers for garbage and trash pickup throughout a gated community.