Skip to content
Georgia Commons
Menu

Rome · Zoning Ordinance

Appendix B - UNIFIED LAND DEVELOPMENT CODE / Article 6 - SUBDIVISION AND PROJECT STANDARDS

6.19.4. Groundwater recharge area protection.

About this text

  • As published by Municode, current through 2026-01-26
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

a . Protected Groundwater Recharge Areas;

Defined.

(1) Significant recharge areas. Significant recharge areas are defined by the Georgia Department of Natural

Resources (DNR) using criteria developed by them, and have been mapped on DNR's Hydrologic Atlas

18 (1989 edition, or as may be amended by DNR from time to time).

(2) Pollution susceptibility category. Categories ofrelative vulnerability of an aquifer to pollution (classified as

"higher," "average" or "lower") are defined by the DNR using criteria developed by them, and have been mapped on DNR's Hydrologic Atlas 20 along with the most significant recharge areas.

b. Protected Groundwater Recharge Area Restrictions; General. Within any significant recharge area, as defined and delineated

by the DNR, the following shall apply:

(1) New hazardous waste treatment or disposal facilities are prohibited.

(2) New sanitary landfills, if permitted, shall have synthetic liners and leachate collection systems.

(3) Any new facility that involves the treatment, storage or disposal ofhaz- C.

ardous waste, if permitted by DNR and the zoning district, shall perform such operations on an impermeable surface having a spill and leak collection system.

(4) Any new facility that handles hazardous materials of the types listed in Section 312 of the Resource Conservation and Recovery Act of 1976 (excluding underground storage

tanks) and in amounts of 10,000 pounds or more on any one day, shall perform their operations on impermeable surfaces having spill and leak collection systems as prescribed by

DNR.

(5) A new above-ground chemical or petroleum storage tank must have secondary containment of 110 percent of the volume of the tank or 110

percent of the volume of the largest tank in a cluster of tanks. This requirement does not apply to:

(a) Any tank having a maximum capacity of less than 660 gallons; and,

(b) Any tank used for agricultural purposes, provided it complies with all Federal requirements.

Protected Groundwater Recharge Area Restrictions; By Classification.

(1) Lower Pollution Susceptibility Areas. Within a significant recharge area classified as having "lower" susceptibility to pollution, the following applies:

(a) New agricultural waste impoundment sites larger than 50 acre-feet must be lined. The

liner must be constructed of compacted clay having a thickness of one foot and a vertical hydraulic conductivity of less

than five x ten-7 cm/sec or other criteria established by the U.S.

Natural Resource Conservation Service.

(b) A new home served by a septic tank/drain field system must be approved by the County Health Department and must have a lot that is at least 110 percent of the minimum lot size required by Table MT-1 of the Department of Human Resource's Manual for On-Site Sewage Management Systems.

(c) Anew manufactured home park served by a septic tank/drain field system must be approved by the County Health Department and must have a lot or space that is at least 110 percent of the minimum lot or space size required by Table MT-2 of

the Department of Human Resource's Manual for On-Site Sewage Management Systems.

(2) Average Pollution Susceptibility Areas. Within a significant recharge area classified as having "average"

susceptibility to pollution, the following applies:

(a) New agricultural waste impoundment sites larger than 15 acre-feet must be lined. The

liner must be constructed of compacted clay having a thickness of one foot and a vertical hydraulic conductivity of less

than five x t en-7 cm/sec or other criteria established by the U.S.

Natural Resource Conservation Service.

(b) A new home served by a septic tank/drain field system must be approved by the County Health Department and must have a lot that is at least 125 percent of the minimum lot size required by Table MT-1 of the Manual for On-Site Sewage Management Systems.

(c) Anew manufactured home park served by a septic tank/drain field system must be approved by the County Health Department and must have a lot or space that is at least 125 percent of the minimum lot or space size required by Table MT-2 of

the Department of Human Resource's Manual for On-Site Sewage Management Systems.

(3) Higher Pollution Susceptibility Areas. Within a significant recharge area classified as having "higher"

susceptibility to pollution, the following applies:

(a) All new agricultural waste impoundment sites must be lined.

The liner must be constructed of compacted clay having a thickness of one foot and a vertical hydraulic conductivity of less than five x ten-7 cm/sec or

other criteria established by the U.S. Natural Resource Conservation Service.

(b) A new home served by a septic tank/drain field system must be approved by the County Health Department and must have a lot that is at least 150 percent of the minimum lot size required by Table MT-1 of the Department of Human Resource's Manual for On-Site Sewage Management Systems.

(c) Anew manufactured home park served by a septic tank/drain field system must be approved by the County Health Department and must have a lot or space that is at least 150 percent of the minimum lot or space size required by Table MT-2 of

the Department of Human Resource's Manual for On-Site Sewage Management Systems.

(d) Spray irrigation of wastewater or the land spreading of wastewater sludges must be approved by DNR.

(e) Permanent storm water infiltration basins are prohibited.

(D New wastewater treatment basins ( except for mining settling basins) must have an impermeable liner and be approved by

DNR.

(Ord. No. 01-7-2, § I, 7-16-01; Ord. No. 05-6-8, §§ I, II, 6-20-05)

Figure 6.1: Standard Detail for Utility Placement ~ ii

I a:

I I I ! I I I I I i!

Ill qi 1., bl fi. Ii I ! !i 1• l i =t I I I II' I ',, ·=J lu I u U' u• I r •• , ;

; ______ ) ____ ~-------------- =rm ..

I ~ I I Figure 6.2: Pavement Replacement for Utility Installations and Other Cut-ins

(~ OF EXCAVATION TO E SIIOOlH OJT

ll>"IIS: IU 1mOO !IIW.l. IE IIACICl'1UED IHJ ACT\JMD to 9511 CX:MPAl:llat QC M SHIE DAY ff 1llOGi IS CIP£N£D.

IN CASES 'MG!£ SI "It Qt PtlO,ECT OQIQllOIIS l'flt'IOC1' ff IIAOCl'1U. NII COIIPACllON (11 A rttwllfli't QJT PRIOR 10 11-£ P: IA.=c~cn:,~'l':;~~_,

l'L\IU OIi OMA APPROWII METHIJOS. 114 MO CASE SIW.1.

IIOADWAY OSIS ABIAIII Ofet CMIIIGNT.

NOT TO SCALE

Art. 6, § 6 .19.4 ROME CITY CODE

Figure 6.3: Typical Residential Roadway Cross-section with Curb and Gutter I .. I

1

• !II 11111 I CI/Jllll"""'\ ll'IIHI- ,'I ,.

T Ft -

50' MIN. R1GiT-OF-WAY

CtJRB & WTTER OPTIONS FOR RESIDENTIAL ROADWAYS NO'IE: ALL CUii OPllOIIS ~ HAY! A IGNIIIAI Cf 2• CClll'AC'IEl> QUCED ~TE BASE I.Ifill M'. QJtll 6 QJTIEJt s•

,... + ,i...;

30" HG-I BACIC OJRB 24" ROLL-OVER 24 " ROME STAl'l>ARO Typical Residential Roadway Cross-section without Curb and Gutter

6.20. Residential Cluster Subdivision Option.

Read this code where it is posted (Municode) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.

Version local-code:rome/zoning/6.19.4@2026-01-26-079c5810db

The assistant can say what this section says in this edition, quoting it and linking to it. It will not apply the law to your situation, and nothing here is legal advice.