Nonresidential uses in the RTF district shall meet the development standards as set forth below.
- 5.8.6 Development Standards for Permitted Nonresidential Uses
- Standards | RTF
- Lot Dimensions [1]
- Lot area (min sq ft) | 20,000
- Lot width (min ft) | 70
- Building Setbacks (min ft)
- Front Yard | 20
- Side (interior) Yard | 15
- Side (street) Yard | 15
- Rear Yard | 25
- From access easement | 5
- Building separation | See Fire Code
- Building Coverage (max) | 45%
- Height (max ft) | 36
- Accessory Structure Setbacks | See Sec. 8.7
- Parking Area Setback (min ft)
- From collector and arterial street rights-of-way | 15
- From local street rights-of-way | 10
- From lane, property line or access easement | 5
- [1] Where a nonresidential use is proposed to be served by private water and/or sewer, additional lot area and/or setbacks may be required by the Chatham County Health Department.