Skip to content
Georgia Commons
Menu

Savannah · Zoning Ordinance

Article 7.0 - Overlay Districts / 7.9 - Victorian Historic Overlay District

7.9.10. Victorian Historic District Design Standards

About this text

  • As published by enCodePlus, retrieved 2026-11-14
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

a. New Construction, Additions, and Alterations The intent of these standards is to ensure appropriate new construction, additions, and alterations within the Victorian Historic District. They are also intended to protect the historic integrity of contributing resources. Designs for new construction are to be consistent with contributing resources from the district’s Period of Significance.

The following design standards shall apply to new construction, additions, alterations to contributing and non-contributing resources, and site alterations, unless otherwise specified. Though certain building materials are prescribed below, the Historic Preservation Commission may approve alternative materials that are not listed as prohibited upon a showing by the applicant that the material or product is visually compatible with historic building materials and has performed satisfactorily in the local climate.

i. Setbacks The front, rear and side yard setbacks for the principal building shall be determined by the base zoning district.

ii. Height and Mass The intent of these standards is to ensure that the height and mass are in context with contributing buildings in the same or adjacent block faces.

1. The height and mass shall be subdivided both horizontally and vertically to convey human scale and visual interest that reflects the traditional size of buildings.

2. The maximum height, building coverage and building footprint shall be determined by the base zoning district.

3. Floor to Floor Heights

a. In single-family detached, single-family attached, two-family attached, three-family/four-family, and townhouse dwellings, the exterior expression of the height of the first story shall not be less than 11 feet and the height of the upper stories shall not be less than 10 feet.

b. In all other building types, the exterior expression of the height of the first story shall not be less than 13 feet and the height of the upper stories shall not be less than nine (9) feet.

iii. Foundation The intent of these standards is to ensure that foundations match the traditional pattern of construction in height and materials and complement the craftsmanship of contributing buildings.

1. Alterations to contributing resources

a. Foundations shall be repaired rather than replaced, provided however, if the degree of degradation does not allow repair, the degradation shall be photographically documented and verified by the Planning Director and the new foundation shall be of the same materials and configuration as the original foundation.

b. If the original foundation material and/or configuration is unknown, the new foundation material and configuration shall be based on historic context.

c. The space between piers may be filled with heavy gauge wood lattice with at least one-half (0.5) inch thick lattice boards, horizontal boards, brick or true stucco over concrete block. Infill material shall be recessed a minimum of three inches behind the front edge of the pier so that the piers are clearly visible and differentiated.

2. New construction, alterations to non-contributing resources, and additions

a. Materials

i. Foundations shall be constructed of brick, stone or true stucco over concrete block piers.

ii. The space between piers may be filled with heavy gauge wood lattice with at least one-half (0.5) inch thick lattice boards, horizontal boards, brick, or true stucco over concrete block. Infill material shall be recessed a minimum of three (3) inches behind the front edge of the pier so that the piers are clearly visible and differentiated.

iii. Slab-on-grade foundations shall be allowed where the slab has been built up to a minimum of 30 inches.

b. Configuration

i. In single-family detached, single-family attached, two-family attached, three-family/four-family and townhouse dwellings, foundations shall be the average height of foundations on contributing buildings on the block face, or if no contributing buildings exist, shall have a minimum finished floor height of 30 inches above grade. Front porches shall have expressed piers.

ii. Beneath a wood frame building, the foundation shall be recessed and not project forward of the building plane.

iv. Exterior Walls The intent of these standards is to ensure that exterior building walls reflect and complement the traditional materials and construction techniques of the district’s architecture.

1. Alterations to contributing resources

a. Exterior walls shall be repaired rather than replace, provided however, if the degree of degradation does not allow repair, the degradation shall be photographically documented and verified by the Planning Director, and the new wall shall be of the same materials and configuration as the original wall.

b. If the original wall material and/or configuration is unknown, the new wall material and configuration shall be based on historic context.

c. Prohibited materials: Vinyl siding, aluminum siding, rolled asphalt, precast concrete panels, fiber cement wood siding, EIFS, one-part stucco, and T-111.

2. New construction, alterations to non-contributing resources, and additions

a. Permitted materials: Brick, stone, wood, true stucco, and wood or fiber cement siding.

b. Prohibited materials: Vinyl siding, aluminum siding, rolled asphalt, precast concrete panels, EIFS, one-part stucco, T-111, corrugated metal, unpainted exposed CMU blocks, fiber cement panels, and metal panels.

v. Windows, Shutters and Storefronts The intent of these standards is to ensure that windows, shutters and storefronts reinforce a sense of rhythm and continuity in architecture and enhance pedestrian activity at the street level.

1. Windows

a. Alterations to contributing resources

i. Windows shall be repaired rather than replaced, provided however, if the degree of degradation does not allow repair, the degradation of each window shall be photographically documented and verified by the Planning Director, and the new window shall be of the same materials and configuration as the original (including single-glazed and true-divided lights, when appropriate).

ii. If the original window material and/or configuration is unknown, or if a new window is proposed in an unoriginal opening, the new window material and configuration shall be based on historic context.

b. New construction, alterations to non-contributing resources, and additions

i. Materials

i. Window casings and sashes shall be made of metal, wood or clad wood material.

ii. Window glass shall be transparent with no dark tints or reflective effects (except for stained glass windows). This provision does not preclude the use of Low Emissivity or laminated glass.

iii. Solid vinyl windows are prohibited.

ii. Configuration

i. Windows shall be taller than they are wide, except for accent windows, which may be round or other shapes.

ii. Windows shall be single-hung, double-hung, triple-hung, awning or casement, except for accent windows which may also be fixed or hopper. Casement windows shall have light divisions.

iii. Simulated divided light windows shall be permitted provided that the muntin is 7/8 inches or less, the muntin profile shall simulate traditional putty glazing, the lower sash shall be wider than the meeting and top rails, and there shall be a spacer bar in between double panes of glass. Between-the-glass, snap-in or applied muntins shall not be permitted.

iv. Framing members shall be covered with appropriate trim; trim shall feature a header, surrounds, and pronounced sill where appropriate.

v. Window sashes shall be inset a minimum of three (3) inches from the façade, except for wood frame buildings.

vi. Bay windows shall extend to the ground unless they are oriel, beveled or are supported by brackets.

vii. All residential facades visible from a street shall incorporate transparent features (windows and doors) over a minimum of 30% of the ground floor façade.

viii. Retail uses shall incorporate transparent features (windows and doors) over a minimum of 70% of the ground floor façade.

ix. All other nonresidential facades shall incorporate transparent features (windows and doors) over a minimum of 50% of the ground floor façade.

2. Shutters

a. Exterior shutters shall consist of a durable wood species.

b. Shutters shall be sized to fit the window and operable (hinged and able to be closed over the window).

c. The placement of the horizontal rail(s) shall correspond to the location of the meeting rail(s) of the window.

3. Storefronts

a. Alterations to contributing resources

i. Original storefronts shall be repaired rather than replaced, provided however, if the degree of degradation does not allow repair, the degradation shall be photographically documented and verified by the Planning Director, and the new storefront shall be of the same materials and configuration as the original.

ii. If the original storefront material and/or configuration is unknown, the new storefront material and configuration shall be based on historic context.

b. New construction, alterations to non-contributing resources and additions

i. Materials

i. Storefronts shall be constructed of wood, cast iron, Carrera glass, aluminum steel or copper as part of a glazed storefront system.

ii. Storefront bases shall consist of wood, bronze, glazed brick or tile.

iii. Exterior burglar bars, fixed or roll-down security devices or similar security devices shall not be permitted.

ii. Configuration

i. Storefront glazing shall be inset a minimum of four (4) inches from the face of the building.

ii. Storefront glazing shall extend from an 18-24 inch tall base of contrasting material or design.

iii. Storefront glazing shall be transparent; provided, however, opaque glass may be used in the storefront window transoms.

vi. Doors/Entrances The intent of these standards is to ensure that the placement of doors and entrances provides a sense of rhythm and continuity in architecture.

1. Alterations to contributing resources

a. Doors shall be repaired rather than replaced, provided however, if the degree of degradation does not allow repair, the degradation of the door shall be photographically documented and verified by the Planning Director, and the new door shall be of the same material and configuration as the original.

b. If the original door material and/or configuration is unknown, or if a new door is proposed in an unoriginal opening, the new door material and configuration shall be based on historic context.

2. New construction, alterations to non-contributing resources, and additions

a. Materials

i. Doors shall be of glass, wood, clad wood or steel without wood grain simulation.

ii. Doors shall not have a decorative diamond inset, half-moon inset, or other prefabricated ornamentation.

iii. Sliding doors shall not be permitted.

b. Configuration

i. Entrances shall face the primary street on which the building is located (normally the street from which it takes its address).

ii. Entrances on corner lots shall be oriented in the same direction as entrances of adjacent buildings, toward the corner of the lot, or based on historic precedent.

iii. Angled entrances shall only be permitted at intersections of streets or lanes.

iv. There shall be a primary entrance along the primary street at intervals no greater than 60 feet.

vii. Porches, Stoops, Balconies and Decks

1. Alterations to contributing resources

a. Porches shall be repaired rather than replaced, provided however, if the degree of degradation does not allow for repair, the degradation shall be photographically documented and verified by the Planning Director, and the new porch shall be of the same material and configuration as the original.

b. If the original porch material and/or configuration is unknown, the new porch material and configuration shall be based on historic context.

c. Front porches shall not be enclosed. Side and rear porches may be enclosed with fine wire mesh, glass or shutters, provided the porch continues to read as a porch and character defining features (including but not limited to columns, balustrades, entablature and similar features) are retained and not obscured or damaged.

d. Prohibited materials: Fiberglass (including Perma-Cast), vinyl and PVC.

2. New construction, alterations to non-contributing resources, and additions

a. Front porches or covered or uncovered stoops shall be required on all entrances for new ground floor residential construction.

b. Materials

i. On porches and stoops, piers and base walls shall be the same material as the foundation wall facing the street.

ii. Porch elements shall be constructed of brick, painted or stained wood, wood composite, precast stone, marble, sandstone or slate.

iii. Prohibited materials: Vinyl and PVC.

c. Configuration

i. On single-family detached, single-family attached, and two-family attached dwellings, a front porch a minimum of six (6) feet in depth shall be required over a minimum of 50% of the front façade.

ii. On three and four-family and townhouse dwellings, a stoop extending a minimum of four (4) feet in depth and six (6) feet in width shall be required.

iii. Wood portico posts shall have a cap and base molding.

iv. Balusters shall be placed between the upper and lower rails, and the distances between balusters shall not exceed four (4) inches on center. The height of the railing shall not exceed 36 inches for single- and two-family dwelling units.

v. Front porches shall not be enclosed.

vi. Uncovered decks shall be at the rear of the building or screened from view from the public right-of-way.

viii. Awnings The intent of these standards is to ensure that awnings provide cover for pedestrians and reinforce the rhythm of bays and primary entrances within facades.

1. Materials Awnings shall be constructed of canvas, cloth or equivalent, metal (though not corrugated), or glass.

2. Configuration

a. A minimum of eight (8) feet vertical height clearance shall be maintained above the public right-of-way.

b. Awnings shall be structurally and architecturally integrated into the façade and shall not obscure character-defining features.

c. Back-lit (internally lit) awnings shall be prohibited.

d. Awnings shall not connect two (2) façades.

ix. Roof The intent of these standards is to ensure that roof forms are designed to provide visual interest and coherence in a manner that is consistent with contributing resources.

1. Contributing Resources

a. Materials

i. Original roofs shall be repaired rather than replaced provided however, if the degree of degradation does not allow repair, the degradation shall be photographically documented and verified by the Planning Director, and the new roof shall be the same material and configuration as the original (except wood or asbestos).

ii. Metal roofs shall have a metal drip edge covering all edges.

b. Configuration

i. Skylights, roof decks, pergolas and roof vents shall be permitted only on the roof plane opposite the street, or when screened from public view and shall not damage or obscure character-defining features.

ii. Dormers shall not damage or obscure character-defining features and shall reinforce the existing historic window pattern.

2. New construction, alterations to non-contributing resources, and additions

a. Materials

i. Roof coverings shall be standing seam metal, v-crimp, slate or equivalent synthetic or architectural asphalt or similar shingles.

ii. Metal roofs shall have a metal drip edge covering all edges and a maximum seam height of one (1) inch.

b. Configuration

i. Shed and porch roofs, subordinate and attached to the primary building, shall be pitched between 2:12 and 6:12. Where historically appropriate, flat roofs may be utilized.

ii. Gable and hip roofs shall be symmetrically pitched between 4:12 and 10:12.

iii. Skylights, and roof vents may be permitted if integrated into roof design.

iv. Pergolas and roof decks shall not be permitted on the street façade.

v. Eaves shall extend no less than 12 inches beyond the supporting walls.

vi. Gable end rakes shall overhang at least eight (8) inches.

vii. Eaves and rakes on accessory buildings and dormers shall overhang at least eight (8) inches.

viii. Soffits shall be placed perpendicular to the building wall, not sloping in plane with the roof (except for gable end rakes).

ix. Applied mansard roofs shall not be permitted.

x. Mechanical Equipment and Refuse The intent of these standards is to ensure that mechanical equipment and refuse is appropriately sited to provide the least negative visual impact. In addition to the requirements set forth in Sec. 9.5, Screening and Buffers, mechanical equipment and refuse shall comply with the following:

1. Electrical vaults, meter boxes, communications devices, and satellite dishes shall be located on the secondary or rear façades and shall be minimally visible.

2. Roof mounted equipment and HVAC units shall be screened from view from the street.

3. Through-the-wall and through-the-window air conditioners shall be located on the secondary or rear facades and shall be minimally visible.

4. Refuse storage areas for dumpsters and compactors shall be located within a building or to the side or rear of the building and screened from the public right-of-way.

5. Alternative energy source devices may be permitted on new construction, additions, and alterations to non-contributing resources provided they are integrated into the building design. Alternative energy source devices may be permitted on contributing resources provided they are not visible from the street and do not damage or obscure any character-defining features.

xi. Lighting The intent of these standards is to ensure that light fixtures have appropriate scale, are sited appropriately, are made of appropriate materials, and complement the building on which they are located. In addition to the requirements set forth in Sec. 9.8, Lighting, lighting shall comply with the following:

1. Materials: Light fixtures shall be constructed of metal and/or glass.

2. Configuration: Light fixtures shall be compatible with the scale of the subject property and with the character of the district.

3. Source Type: White light source only.

xii. Additions In addition to compliance with the Visual Compatibility Criteria and the Victorian Historic District Design Standards, additions to contributing resources shall also comply with the Secretary of the Interior’s Standards and Guidelines for Rehabilitation and the following standards:

1. Additions shall be subordinate in height and mass to the resource.

2. Additions shall not obscure any character-defining features.

3. Additions shall not be on the primary or front façade of the resource.

xiii. Accessory Structures (including garages, carports and accessory dwelling units, excluding fuel canopies) In addition to compliance with the Visual Compatibility Criteria and the Victorian Historic District Design Standards, accessory structures shall also comply with the requirements set forth in Sec. 8.7, Accessory Structures and Uses, and the following standards:

1. New accessory structures shall be located in the rear yard.

2. New accessory structures shall be in scale with other contributing accessory structures on the lane.

3. The height and mass of the primary building shall not be exceeded by any new accessory structure on the same parcel.

4. Accessory structures shall not be more than two (2) stories tall.

5. Garage openings shall not exceed 12 feet in width.

6. New accessory structures may have up to a five (5) foot lane setback to allow a turning radius into the garage.

7. Side yard setbacks for new accessory structures shall be a minimum of three (3) feet.\

xiv. Satellite Dishes

1. Ground mounted satellite dishes shall not be located in a front yard.

2. Ground mounted satellite dishes in the side (street) yard shall be completely screened by a fence or wall or landscaping.

3. Building mounted satellite dishes shall not be located on a street fronting façade (except lanes).

4. Only one (1) satellite dish is permitted per unit.

xv. Fuel Canopies

1. The entire canopy, including columns and roof, shall be architecturally compatible with the design of the principal building.

2. The entire canopy, including columns and roof, shall be constructed of building materials consistent with the principal building.

3. A canopy may be counted toward the building frontage requirements, if applicable to the district, only where the spacing of columns along the frontage is no greater than 20 feet and where the columns are placed at the edge of the canopy.

b. Parking and Paving The intent of these standards is to create and protect contiguous, active pedestrian street fronts. The use of pervious paving shall be encouraged. In addition to the requirements set forth in Sec. 9.3, Off-Street Parking and Loading, parking and paving shall comply with the following:

i. New construction shall include a private sidewalk that connects the main entrance of the principal structure to the public sidewalk. Private sidewalks shall be constructed of brick, concrete, stone or other materials as approved by the Planning Director.

ii. Parking areas shall be located in the rear yard except for single- and two-family dwelling units which may also provide parking in the side yard behind the face of the front façade.

iii. Structured parking within the first story of a building shall be setback a minimum of 30 feet from property lines along public rights-of-way (not including lanes). This standard does not apply to structured parking on the same lot as single family and two family residential dwellings that are on a corner lot with lane access or on a parcel that does not have access to a lane.

iv. Parking Lots Over 30 Feet in Length Where a parking lot extends over 30 feet in length along any street, a 36-inch high wall shall be placed parallel to the building façade along the parking lot in order to screen vehicles. Shrubs that are anticipated to grow to a height of less than 36 inches shall be planted between the wall and the adjacent sidewalk.

v. Vehicular Access

1. For single and two-family dwellings, where a site has access to a lane, the lane shall be the sole means of vehicular access to the site. Where lane access is not available, a driveway shall be permitted from the street provided that it is a ribbon strip design. The driveway shall be no wider than 12 feet and the area between the strips shall be planted with grass or plants that grow or are maintained to no taller than one-half foot.

2. For uses other than single and two-family dwellings, vehicular access shall be from the lane. Where there is no lane, the Planning Director and the City Manager or his or her designee shall consult with each other to determine the most appropriate access location.

vi. Parking Structures Parking structures shall comply with the Visual Compatibility Criteria, Victorian Historic District Design Standards, and the following standards:

1. There shall be no exterior evidence at the ground level to indicate that the parking structure is used for parking, except for ingress and egress. At the ground floor level each visible portion of the structure shall be wrapped in residential or nonresidential uses permitted in the base zoning district.

2. In-structure parking may extend to within three (3) feet of the rear lot line where parking access is provided from a lane.

c. Fencing and Walls The intent of these standards is to ensure that walls and fences define outdoor spaces appropriately, separate the private and public realms and add architectural interest to a building’s façade. In addition to compliance with the requirements set forth in Sec. 9.6, Fences and Walls, fences and walls shall also comply with the following standards:

i. Materials

1. Permitted: Wood, iron, brick, true stucco over concrete block, or extruded aluminum.

2. Prohibited: Chain-link, vinyl, PVC, and corrugated metal.

ii. Configuration

1. Fences or walls no more than 36 inches in height may be installed within the front yard.

2. Fences or walls no more than eight (8) feet in height may be installed within the side or rear yards behind of the front façade of the building.

3. A minimum of five (5) feet must be provided between a fence and a building where they are parallel.

History

The history line the source prints at the end of the section.

(Ord. of 05-14-2020(39), § 1, Ord. of 11-22-2022(11), § 1, Ord. of 9-12-2024(21), § 1)