To ensure compatibility with surrounding land uses, protect public safety and natural, cultural and scenic resources and preserve and enhance the character of neighborhoods, all WCFs subject to this Section shall be located, developed and operated in compliance with the following:
a. Siting and Location WCFs are allowed in all zoning districts, subject to the limitation set forth herein. Siting of WCFs shall be in accordance with a hierarchy of facility alternatives. If a WCF is proposed that is a lower-ranking facility than the most preferred facility type (concealed attached), an Evidence of Need Report as specified in Sec. 8.9.4.c. shall be provided. Whenever feasible, a new facility, not to include collocation or combined antennas, should be located on City property to ensure that regular maintenance of the facility, as required by Sec. 8.9.7, is occurring.
- Table 8.9-1 Hierarchy by Facility Type
- Priority | Facility Type | Example
- Most Preferred Least Preferred | Concealed Attached [1]
- Collocated or Combined on Existing Antenna Support Structure or on Athletic Field Light Poles or Water Tanks (at least 50 feet in height) [2]
- Concealed Freestanding
- Non-concealed Attached [3]
- Non-concealed Freestanding (Monopole Only) [4]
- [1] An applicant does not have to provide a concealed attached facility if collocation on an existing antenna support structure or other structure (i.e., athletic field light pole or water tank) is available within the applicant’s geographic search area provided that the structure is not located within a Residential district, recognized historic area or within the scenic vistas/landscapes identified in Sec. 8.9.5.h unless approved by the Planning Commission. DAS are subject to applicable design review as part of a Local System Master Plan. [2] DAS and small cell installations may collocate on a utility structure less than 50 feet in height provided that the height of the utility structure is not increased by more than five (5) feet. [3] May be allowed within a recognized historic area with Planning Commission approval, but not on a contributing structure. [4] Not allowed within a Residential district, a recognized historic area or within 100 feet of either. A setback waiver may be requested if the criteria in Sec. 8.9.5.c.i. (2) can be met.
b. Height
i. General Height shall be measured as specified in Sec. 4.1.8.
ii. Height, Maximum
- Table 8.9-2 Maximum Height by Type of Facility
- Maximum Height by Type of Facility
- Type of Facility | Maximum Height
- Concealed Attached | Shall not exceed the height of the structure on which the facility is attached by more than 20 feet.
- Non-concealed Attached | Shall not exceed the height of the structure on which the facility is attached by more than 20 feet.
- Collocation or Combined on Existing Structure (General) | A new WCF located on any of the following structures existing on the effective date of this Section shall be exempt from height restrictions provided that there is no increase in height of the existing structure as a result of the installation: water towers, guyed structures, lattice structures; police, fire, ambulance and other emergency dispatch and public works structures and monopoles.
- Collocation on Existing Structure at least 50 feet in height (Utilities) | A new WCF located on any utility structure shall be exempt from height restrictions of this Section provided that there is no more than a 20-foot increase in the height of an existing structure as a result of the installation. DAS and small cell installations, may collocate on a utility structure less than 50 feet in height provided that the height of the utility structure is not increased by more than five (5) feet.
- Collocation on Existing Buildings and Structures (Legal Nonconforming) | A WCF may locate on a building or structure that is legally non-conforming with respect to height, provided that the facility does not project above the existing height by more than 20 feet.
- Concealed Freestanding | Shall not exceed 45 feet above the maximum allowable zoning district building height or a total of 100 feet, whichever is less.
- Non-concealed Freestanding (Monopole) | Up to 199 feet provided that the applicant has provided evidence of need.
iii. Height, Flexibility The Planning Commission may approve additional height beyond the maximum allowed if findings can be made that siting of the proposed WCF is appropriate to the context of the proposed location using the criteria listed in Sec. 8.9.5.d.
c. Setbacks All WCFs and their equipment enclosures and ancillary structures shall comply with the setback provisions of the zoning district in which the WCF is located. In addition, the following setbacks shall be observed:
i. Setbacks Required
1. In order to ensure public safety, the minimum distance from the base of any non-concealed freestanding WCF to any property line, road, dwelling, commercial or institutional use or public recreational area shall be the height of the antenna support structure, including any antennas or other appurtenances, if the WCF has not been constructed with breakpoint design technology.
2. The setback may be reduced by the Planning Commission if documentation filed by a Georgia-licensed professional structural engineer certifies that the WCF utilizes breakpoint design technology. The minimum setback shall be equal to 110% of the distance from the top of the structure to the breakpoint level of the structure, plus the minimum setback distance of the zoning district. For example, a non-concealed WCF of 100 feet in height with a breakpoint at 80 feet, the minimum setback would be 22 feet (110% of 20 feet-the distance from the top of the WCF) plus the minimum setback for the zoning district.
3. The Planning Commission may waive all or part of a required setback if the applicant can demonstrate that the proposed facility will be the least visually obtrusive profile, will not detract from the beauty and/or character of the area in which the WCF is proposed, and will not cause a public safety issue.
4. Setbacks from Residential districts, recognized historic areas, and certain scenic vistas and landscapes for non-concealed freestanding WCFs, as described in Sec. 8.9.5.h, are also required. If more than one standard applies, the more restrictive standard shall govern.
ii. Setback not Required A setback is not required by this Section for concealed freestanding and attached WCFs. However, the setback provisions of the base zoning district shall apply. In the case of pre-existing non-conforming structures, a WCF (including its equipment compound and/or cabinetry and ancillary structures) shall not increase any non-conformities, except as provided in Sec. 8.9.9.
d. Aesthetics / Visibility To protect the beauty and character of the City, particularly Residential districts, recognized historic areas and certain scenic vistas and landscapes as identified herein, all facilities shall be screened to the greatest extent possible. Screening shall occur through the use of design, existing buildings and structures, existing and proposed vegetation, appropriate materials and color. Unlike non-concealed facilities, concealed facilities shall not be identifiable as a WCF.
- Table 8.9-3 Visibility of Facility
- Screening and/or Concealment Techniques | Applicable WCF | Explanation
- Design | Concealed Attached Concealed Freestanding | Concealed Attached: Feed lines and antennas shall be designed to architecturally match the façade, roof, wall or structure on which they are affixed in order to blend in with the existing structural design, color and texture and in order to provide the least visually obtrusive profile. Concealed Freestanding: Such facility shall blend into its surroundings through design and siting that is appropriate and typical to the context of the proposed location. Such facility shall also be designed to appear as a structure that would be allowed in the zoning district in which it is proposed to be located and that is customary to the location (e.g., a smokestack would not be allowed in a residential district). Examples of concealed facilities include chimneys, steeples, clock towers, light poles, and flag poles. Guyed structure and lattice structure construction is not allowed.
- Existing Buildings and Structures | Non-concealed Attached and Combined Non-concealed Freestanding | Roof Mount: When a WCF extends above the roof height of a building on which it is mounted, the WCF shall be camouflaged within or behind existing architectural features to limit the visibility from public rights-of-way. The WCF should be stepped back from the façade in order to limit its impact on the building’s silhouette. Side Mount: The WCF shall blend with the building’s existing architecture and shall be painted or shielded with material which is consistent with the design features and materials of the building. DAS and Small Cell Installations: If not visible from public rights-of-way or designed to resemble normal architectural features of the structure to which it is attached. Freestanding Non-concealed: To the extent possible, existing buildings and structures should be used to screen a WCF from rights-of-way.
- Existing and Proposed Vegetation | Non-concealed Freestanding Non-concealed Attached Collocation and Combined | Non-concealed Freestanding: The perimeter of the WCF shall be at least 15 feet in width for landscaping and include: 1. a row of evergreen trees a minimum of 10 feet in height at the time of planting with a minimum two-(2) inch caliper, spaced a maximum of 12 feet apart; and, 2. a row of evergreen shrubs a minimum of two (2) feet tall at the time of planting, planted four (4) feet on center. Within a year of planting, the trees and shrubs shall achieve 80% opacity of the security barrier and/or equipment enclosure. Existing trees and vegetation may be used as an alternative or in combination with new plantings to achieve the opacity requirement subject to approval of the Planning Commission upon a recommendation of the City Manager or his or her designee. An easement may be required to ensure that vegetation remains intact. Non-concealed Attached: To the extent possible, vegetation should be used to screen a WCF from full view. Collocation and Combined: If the equipment compound and/or landscaping is not in compliance with this Section, compliance shall occur at the time of antenna installation. Landscaping compliance may be waived, wholly or partially, if the site lacks sufficient area.
- Color | Non-concealed Freestanding Attached Non-concealed Collocation and Combined | Non-concealed Freestanding: The WCF shall maintain a galvanized gray finish or the Planning Commission may accept other contextual or compatible color, except as required by federal rules or regulations. Non-concealed Attached: The WCF shall be painted and/or constructed of materials to match the color of the building or structure on which it is attached, except as required by federal rules or regulations.
- Antenna | Non-concealed Freestanding | The first antenna placement, and all subsequent collocated antennas, on new antenna support structures shall be flush-mounted, unless it is demonstrated through RF propagation analysis that such antennas will not meet the network objectives of the desired coverage area.
A. e. Equipment Compound and/or Equipment Cabinetry Equipment related to the operation of a WCF shall be hidden and/or screened from public view by one or more of the following techniques, which shall also be consistent with the aesthetic/visibility standards identified in Sec. 8.9.5.d.:
i. Ground equipment, including platforms One or more of the following techniques can be used to hide and/or screen equipment:
1. Locate equipment underground. If a non-concealed freestanding WCF is proposed, an opaque security barrier consisting of brick, masonry, or other material approved by Planning Commission shall be installed around the antenna support structure that will prevent unauthorized access to the structure. Landscaping as identified in Sec. 8.9.5.d. shall be provided.
2. Locate equipment within a building. The building shall be designed to be consistent with the prevailing architectural style of the neighborhood in which it is located, including exterior materials and roof pitch. The enclosure shall not exceed one story, unless location in a flood plain or other drainage concerns requires it to be elevated.
3. Locate equipment behind a secured, landscaped perimeter. An evergreen landscape buffer shall surround the perimeter of the WCF. If this method is selected, the buffer requirements identified in Sec. 8.9.5.d. apply. Additionally, an opaque fence or wall shall be constructed to minimize opportunities for unauthorized access, climbing, vandalism, graffiti and other conditions that would result in hazardous conditions, visual blight and attractive nuisances. The fence or wall shall be no less than the above grade height of any equipment within the enclosure, which shall not be taller than one story, unless located in a flood zone.
ii. Roof-top equipment Equipment shall be screened from public view in a manner that is consistent with the architectural style of the building upon which the WCF is located.
f. Lighting and Signage
i. Wireless communications facilities taller than 199 feet shall be lit according to FAA standards, including light intensity and flashes per minute. When applicable, dual lighting systems shall be employed. This dual lighting system includes red lights (L-864) for nighttime and medium intensity flashing white lights (L-865) for daytime and twilight use. This lighting system may be used in lieu of operating a medium intensity flashing white light system at night.
ii. Free-standing wireless communications facilities between 100 and 199 feet shall be equipped with the following:
1. Red lights (L-864) for nighttime (only) – strobe lighting of any kind is not permitted; and,
2. White reflective tape/sheeting installed at 20 feet above ground level and continuing upward at ten foot intervals.
iii. Wireless communications facilities less than 100 feet shall be lighted only if required by the FAA and shall not exceed the minimum standard required by the FAA. Non-daytime strobe lighting shall not be allowed unless specifically required by the FAA.
iv. Lighting of equipment enclosures and other ancillary structures on site shall be shielded from adjacent properties. The foot candle measurement at property lines shall be no more than 1.0 foot candle when measured at grade. FAA required lighting is exempt from this requirement.
v. Signs shall be limited to those needed to identify the WCF, the owner, the party responsible for the operation and maintenance (including address and telephone number), to warn of danger and to comply with applicable federal regulations. Such signage shall be visible and legible at ground level.
g. Recognized Historic Areas
i. Freestanding WCFs within a recognized historic area shall be concealed. Attached WCFs proposed for existing structures shall also be concealed unless it can be demonstrated that the facility will not be visible from ground level.
ii. Any WCF located attached to or within an historic building or structure shall not alter the character-defining features, distinctive construction methods or original historic materials of the building or structure.
iii. A Certificate of Appropriateness is required.
h. Scenic Vistas and Landscapes To preserve scenic vistas and landscapes, any non-concealed freestanding WCF shall:
i. Not be developed on a hammock or back-barrier island.
ii. Be separated from the following areas by the following distances:
1. Residential districts, conforming residential uses, recognized historic areas: 100 feet.
2. Public rights-of-way: 100 feet.
3. Protected and Restricted Roadways as identified in this Ordinance: 300 feet.
4. Amenity corridors as identified in the 2030 Long Range Transportation Plan: 300 feet.
5. Marshes, to include estuarine waterways and/or Spartina marshes: 500 feet. The distance shall be measured from the jurisdiction line established by the Georgia Department of Natural Resources.
6. Protected river corridors as identified in the River Corridor Protection Act (O.C.G.A. 12-2-8, as amended): 500 feet. The distance shall be measured from the jurisdiction line established by the Georgia Department of Natural Resources.
iii. The Planning Commission may waive all or part of separation distance if the applicant can demonstrate that the proposed facility will be the least visually obtrusive profile and not detract from the beauty and/or character of the scenic vistas and landscapes identified within this Subsection.
i. Antenna Support Structure Multiple User Standards If a freestanding WCF is proposed, it shall be engineered and constructed to accommodate multiple users, as indicated below:
i. Ninety (90) feet or less in height: at least three (3) antenna arrays.
ii. More than 90 feet and up to 120 feet in height: at least four (4) antenna arrays.
iii. More than 120 feet and up to 150 feet in height: at least five (5) antenna arrays.
iv. More than 151 feet and up to 199 feet in height: at least six (6) antenna arrays.
v. If the Planning Commission approves a height of more than 199 feet, additional antenna arrays may be required.
j. Structural Integrity All WCFs and antenna support structures shall be designed to meet or exceed all federal, state and local building code requirements, including windloading and American National Standards Institute standards (EIA/TIA) Document 222-F, Structural Standards for Steel Antenna Towers and Supporting Structures, for the Wind Code Zone for Chatham County, Georgia and any state/county building codes (as they may be amended and/or updated from time to time). Structural integrity shall be certified by a Georgia-licensed professional engineer.
k. Environmental Standards The following standards shall apply:
i. Freestanding WCFs shall not be located in wetlands or wetlands buffers, whether federal or state designated.
ii. Freestanding WCFs shall not generate noise in excess of 60dB at the property line. Attached WCFs shall not generate noise in excess of 60dB at ground level at the base of a habitable building closest to the facility.
l. Safety Standards
i. Radiofrequency Radiation (RFR) Standards All equipment for a WCF shall be authorized per the FCC Guidelines for Evaluating the Environmental Effects of Radiofrequency Radiation. Documentation shall be provided that these guidelines will be met.
ii. Interference with Public Safety Communications
1. In order to facilitate the regulation, placement, and construction of a WCF and its interaction with public safety communications equipment, an applicant requesting such a facility shall agree in a written statement, to the following:
a. Compliance with FCC regulations regarding susceptibility to radio frequency interference (RFI), frequency coordination requirements, general technician standards for power, antenna, bandwidth limitations, frequency stability, transmitter measurements, operating requirements and any and all other federal statutory and regulatory requirements relating to RFI; and
b. In the case of collocation of facilities, the applicant, together with the owner of the site, shall provide a composite analysis of all users of the site to determine that the proposed facility will not cause RFI.
2. When such a base station is identified as causing RFI, the following shall occur:
a. The governing jurisdiction shall provide notification to all WCF service providers operating in the jurisdiction of possible interference with the public safety communications equipment. Upon such notification, the owners shall use their best efforts to cooperate and coordinate with the jurisdiction and among themselves to investigate and mitigate the interference, if any, utilizing the procedures set forth in the joint wireless industry-public safety Best Practices Guide, released by the FCC in February 2001, including the Good Engineering Practices, as may be amended by the FCC from time to time.
b. If any WCF provider fails to cooperate with the governing jurisdiction in complying with the owner’s obligations under this Section or if the FCC makes a determination of RFI with the governing jurisdiction’s public safety communications equipment, the owner who fails to cooperate and/or the owner of the WCF which caused the interference shall be responsible, upon FCC determination of radio frequency interference, for reimbursing the governing jurisdiction for all costs associated with ascertaining and resolving the interference including, but not limited to, any engineering studies obtained by the jurisdiction to determine the source of the interference. For the purposes of this subsection, failure to cooperate shall include failure to initiate any response or action as described in the Best Practices Guide within 24 hours of the governing jurisdiction’s notification.