--- title: Savannah Zoning Ordinance, A-2.33 Memorial Health University Medical Center (MHUMC) PD collection: local-codes id: local-code:savannah/zoning/a-2.33-memorial-health-university-medical-center-mhumc-pd cite_as: Savannah, Ga., Zoning Ordinance, A-2.33 Memorial Health University Medical Center (MHUMC) PD canonical_url: https://georgiacommons.org/code/local/savannah/zoning/a-2.33-memorial-health-university-medical-center-mhumc-pd md_url: https://georgiacommons.org/code/local/savannah/zoning/a-2.33-memorial-health-university-medical-center-mhumc-pd.md text_url: https://georgiacommons.org/code/local/savannah/zoning/a-2.33-memorial-health-university-medical-center-mhumc-pd/text source_url: https://online.encodeplus.com/regs/savannah-ga/doc-view.aspx?secid=6683&h=1 date: 2026-11-14 status: active jurisdiction: city:savannah jurisdiction_name: Savannah place_fips: "1369000" corpus_version: local-codes-savannah-495e0c8a3648 publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/code/local/savannah/zoning/~appendix-a-2.md previous: https://georgiacommons.org/code/local/savannah/zoning/appendix-a-2-article-5.0-5.2-3.md next: https://georgiacommons.org/code/local/savannah/zoning/a-2.34-dawes-avenue-pd.md index: https://georgiacommons.org/code/local/savannah.md branch: zoning edition: As published by enCodePlus, retrieved 2026-11-14 edition_date_kind: retrieved source_publisher: enCodePlus version_id: local-code:savannah/zoning/a-2.33-memorial-health-university-medical-center-mhumc-pd@2026-11-14-6ef8fc6af5 --- # Savannah Zoning Ordinance, A-2.33 Memorial Health University Medical Center (MHUMC) PD > As published by enCodePlus, retrieved 2026-11-14 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. > Tables are shown as their rows, with the cells separated by a bar ( | ). > This section's figures, maps, or images are in the source and are not shown here. Part of: Appendix A-2 - Planned Development Districts A-2.33 Memorial Health University Medical Center (MHUMC) PD The purpose of the proposed Master Plan Amendment is to rezone the parcels within the current MHUMC PD. The planned districts within the PD will address future building, structured parking and surface parking improvements within the campus of the Memorial Health University Medical Center. This document is intended to define the districts illustrated in the Master Plan Amendment graphics (see attached). a) General Provisions (1) Conflicts. In the case of any conflict between a specific regulation set forth in this Section and any regulation set forth elsewhere in this Chapter or this Code, the regulation in this Section shall apply unless expressly prohibited. For standards where this Section is silent, the applicable sections of this Chapter shall apply. Setbacks set forth in this Section are subject to any greater specific setbacks indicated on the Master Plan Amendment graphics. (2) Measurements. Building Setbacks. The setback for any principal use building, unless specified elsewhere by this Section, shall be from the property line except at property lines between MHUMC parcels. There shall be no setbacks between MHUMC parcels. (3) Pedestrian Connectivity. For any future development, Master Developer shall construct sidewalks in connection with such future development in order to provide sidewalk connections between new public entrances, existing campus sidewalk infrastructure and adjacent parking areas. Proposed sidewalk connections will be submitted with each new Site Plan application. b) Modifications and Variances to the Adopted PD Standards that are specific to the MHUMC PD may be modified, as provided in Sec. (b)(1) below but cannot be varied by the Planning Commission or Zoning Board of Appeals. Standards that can be varied are described below in Sec. (b)(2). (1) *Modifications.* Any desired modification other than those provided below would require an amendment to this Section per Section 6.1.22 of the zoning Ordinance. (2) *Variances.* Only dimensional standards can be varied in the MHUMC PD. The variance process for modifications other than those listed in part (b)(1) above shall follow the procedure established in Article 3.0 (Application and Review Procedures). c) Administration and Enforcement Administration and enforcement of this Section shall follow the process described in Article 2.0 (Review Bodies and Administrators) of this Chapter. d) Master Plan. (1) *Districts.* Each district within the master plan has a district that corresponds to the uses permitted in that area, similar to a zoning district. Uses permitted in each designation are located in Sec. (e). Where use standards are not provided in the table, they shall be set according to the OI or OI-E default zoning district assigned to each district in the master plan and listed in Bulk Regulations. The master plan is provided at the end of this document. (2) *Modification to the Approved Master Plan.* Any change to the approved master plan tract boundaries, permitted uses, or default zoning district shall require approval by the Mayor and Aldermen. e) Bulk Regulations Bulk regulations for each district within the MHUMC PD are included in the tables below. Where the tables do not provide specific regulations within a district, default fallback zoning districts have been providedA. DISTRICT 1 Uses | All uses allowed in OI-E zoning plus Emergency Medical Services (EMS) substation,/Ambulance Service & Emergency shelter except for the following prohibited uses: Transmission towers General Maximum Building Height | 200 feet Front Setback | 15 feet Side/Rear Setback | 15 feet 10 feet Parking Requirements (1) | Per Section 9.3 Off-Street Parking & Loading of current Zoning Ordinance Parking Impervious Maximum | None Required Bicycle Parking | N/A Use Buffer Class (Sec. 9.5.4) | 3 Fallback Zoning (2) | OI-E DISTRICT 2 Uses | All uses allowed in OI-E zoning plus Emergency Medical Services (EMS) substation/Ambulance Service & Emergency shelter except for the following prohibited uses: Transmission towers General Maximum Building Height | 120 feet Front Setback | 15 feet Side/Rear Setback | 15 feet 10 feet Parking Requirements (1) | Per Section 9.3 Off-Street Parking & Loading of current Zoning Ordinance Parking Impervious Maximum | None Required Bicycle Parking | N/A Use Buffer Class (Sec. 9.5.4) | 3 Fallback Zoning (2) | OI-E DISTRICT 3 Uses | All uses allowed in OI-E zoning plus Emergency Medical Services (EMS) substation/Ambulance Service, Emergency shelter, single family residential and townhomes except for the following prohibited uses: Transmission towers General Maximum Building Height | 75 feet Front Setback | 15 feet Side/Rear Setback | 15 feet 10 feet Parking Requirements (1) | Per Section 9.3 Off-Street Parking & Loading of current Zoning Ordinance Parking Impervious Maximum | None Required Bicycle Parking | 1% of code required parking Use Buffer Class (Sec. 9.5.4) | 2 Fallback Zoning (2) | OI-E DISTRICT 4 Uses | All uses allowed in OI zoning plus single family residential and townhomes General Maximum Building Height | 50 feet Front Setback | 5 feet Side/Rear Setback | 15 feet 10 feet Parking Requirements (1) | Per Section 9.3 Off-Street Parking & Loading of current Zoning Ordinance Parking Impervious Maximum | Per Section 9.3 Off-Street Parking & Loading of current Zoning Ordinance Required Bicycle Parking | 1% of code required parking Use Buffer Class (Sec. 9.5.4) | 2 Fallback Zoning (2) | OI DISTRICT 5 Uses | Conservation General Maximum Building Height | N/A Front Setback | N/A Side/Rear Setback | N/A Parking Requirements (1) | N/A Parking Impervious Maximum | N/A Bicycle Parking | N/A Use Buffer Class (Sec. 9.5.4) | 1 Fallback Zoning (2) | OI Footnotes: (1) Remote parking has no distance limit. In addition, site is to be considered conforming for parking as of the effective date of this rezoning and any future development is only responsible for its parking requirements and replacement of parking removed for new development. (2) Each building can be considered a separate principal use for the purpose of signage. ## History (Ord. of 1-22-2026(20), ยง 1B)