The purpose of this section is to regulate the street-front buildings envisioned for the district in order to provide an appropriately scaled and designed pedestrian environment reflective of the historic town center. See Building Design and Design Illustrations Figure 10.0 for reference on the following items. (1) Architecture and building materials. Principal and accessory buildings shall be designed to comply with this article and the historic district of Downtown Senoia Design Guidelines. (2) Building height. The principal building shall not be taller than three stories or 40 feet as measured from the natural grade at the front corners of the building to the ridgeline or parapet, whichever is greater. The ground floor is located at grade with a floor to ceiling height of 12 feet to 16 feet. Upper floors shall have a floor to ceiling height of nine feet to ten feet. Accessory buildings may be no taller than the principal building. (3) Building massing. The building massing is regulated by whether it has a pitched roof or flat roof configuration. a. Pitched roof. 1. One story buildings with a pitched roof shall have a maximum cornice height of 18 feet. 2. Two story buildings with a pitched roof shall have a maximum cornice height of 26 feet. 3. Pitched roofs must not extend more than ten feet above the eaves if the roof pitch is 5:12 to 13:12. 4. Pitched roof structures may contain additional floor area within the roof which may include dormers. b. Flat roof. 1. Parapets must extend a minimum of three feet above the top of the roof structure. This minimum height is intended to ensure that all rooftop equipment is hidden from public view. 2. Parapets must occur within the maximum building height, except that a portion of the parapet no more than more than one third the width of the corresponding façade may extend up an additional five feet. 3. Buildings with a flat roof and parapet are not required to have a cornice/eaves line distinct from the top of the parapet. 4. All rooftop equipment shall fall within the permissible roof heights, be located away from slopes or areas exposed to the public street, and otherwise be screened from view from adjacent public streets or be incorporated into the skin of the building or internal to the block. (4) Façade bay rhythm: a. Differentiated bays should be expressed on each façade of a building directly fronting a public space or street. b. Bays shall be a minimum of eight feet and a maximum of 24 feet wide on primary frontages. c. On any façade that is visible from a public right-of-way that is directly adjacent to an area of primary frontage, at least one bay shall be articulated on the corner adjacent to the primary façade. d. Where these façades are over 60 feet in length, they must have architectural articulation, such as bays or pilasters, for at least 20 percent of the façade in addition to the first bay adjacent to the primary façade. (5) Building frontage. Buildings may front the street In a number of different ways. The building's frontage is the combination of its façade arrangement (windows and doors), any structures that project from the façade, such as porches, terraces, stoops, awnings, or bay windows and the distance of the building from the street. See Building Frontage Examples Figure 11.0. See Primary Frontage Components Figure 12.0. (6) Fenestration ratio. The punctuation (door and window openings) in a building's façade is referred to as its fenestration. Two important factors of regulating fenestration are: 1) to ensure an appropriate ratio of openings to wall surface for a building façade, and 2) to ensure a degree of transparency or visual connection between the outside and inside. When calculating the fenestration area, door and window units including frames and trim may be included, however any recess or panel that does not also have a degree of transparency may not be counted. Doors that do not include glass or windows that may have opaque glass or other view-obscuring elements may only contribute up to five percent of the fenestration ratio for that floor level and also fenestration ratio figure 13.0. a. On the primary façade facing the primary street, the ground floor fenestration ratio should be between 40 percent and 55 percent. b. On the primary façade, upper floor(s) fenestration ratio should be between 25 percent and 40 percent. c. Commercial street fronts along the ground floor of a building shall be designed to permit maximum flexibility for subdividing commercial spaces. (7) Entrances. Most buildings should have two equally inviting and accessible entrances. One on the primary façade facing the primary frontage and one on a secondary façade with convenient access to the main parking lot. (8) Any exhaust vents on the roof or walls shall be placed on non-street facing planes, to the extent possible.