(a) Streetlights shall be provided along all public rights-of-way utilizing decorative light poles and fixtures consistent with the design adopted by the City of Senoia for the overlay.
Streetlights shall be staggered, spaced no more than 150 feet on-center, along both sides of the roadway.
(b) Lighting in parking areas shall provide area lighting sufficient to achieve a minimum illumination of two foot-candles and maximum of five foot-candles of light as measured at grade level and recommended in the IESNA Lighting Handbook. Maximum pole light height for parking areas is 20 feet.
(c) Lighting of loading areas shall follow the illumination requirements of parking areas, and should be non-intrusive to neighbors. Separate controls, such as motion detectors or timers are encouraged for loading areas.
(d) All building entrances, walks and vehicular access shall be illuminated up to a maximum of five foot-candles of light as measured at grade level and recommended in the IESNA Lighting Handbook.
The following steps should be taken to control light trespass problems, including nuisance glare:
(1) Prior to design and installation, inspect areas adjacent to the lighting design location to identify and consider any potential problems involving neighboring residences and roadways.
(2) Select luminaires that have tightly controlled intensity distributions, using full cutoff reflectors and refractors.
(3) Contain light within the design area by carefully selecting, locating, mounting, and aiming (when appropriate) the luminaires.
(4) Use well-shielded luminaires (or select equipment that can be shielded) if a potential problem is found after installation.
(5) Keep floodlight aiming angles low so that the entire beam always falls within the intended lighted area during (and after) the design and installation process. This lighted area should be fully within the lighting design location and have no spillover to neighboring properties.
(6) Where adjacent to residential uses, illumination shall not exceed 0.3 foot-candle at ten feet beyond property line.
Each of the lighting fixtures chosen for this overlay district will need to adhere to the following criteria:
(1) Light color is to be white, preferably 3,500 Kelvin, but with any adjustable range from 2,800 to 5,000 Kelvin.
(2) The color rendering index must be 80 or greater.
(3) The fixtures shall be primarily down-firing. Up-firing fixtures, if used for aesthetic effect, must be aimed at white horizontal reflectors to produce diffused light downward to prevent dark sky intrusion.
(4) The light source should not be visible to drivers, bicyclists, or pedestrian unless they are directly under the fixture.
(5) All luminaires should be control-ready with the ability in the future to be individually monitored and controlled by wired or wireless central networks.
(6) Luminaire design (light poles, posts, fixtures, globes, etc.) should be compatible with the local context.
History
(Ord. No. 21-16, § 2, 11-15-2021)