Sec. 74-243. Fire safety in nonresidential districts and planned developments.

About this text

  • As published by Municode, current through 2025-12-10
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

Accessibility for fire fighting equipment on a hard-surfaced subbase (subgrade plus an asphalt first layer or bound crushed stone aggregate) shall be maintained throughout all stages of construction in all nonresidential districts and planned developments. Minimum widths of private access driveways with a development, excluding parking, shall be 20 feet, and the minimum turning radii shall be 35 feet. Fire hydrants and water service shall be installed to within 300 feet of units under construction before proceeding with framing.

History

The history line the source prints at the end of the section.

(Ord. No. 07-05, Art. 11, § 11.11, 12-3-2007)