--- title: Smyrna Zoning Ordinance, 1101.3. Storm drainage system. The storm collection: local-codes id: local-code:smyrna/zoning/1101.3 cite_as: Smyrna, Ga., Zoning Ordinance ยง 1101.3 canonical_url: https://georgiacommons.org/code/local/smyrna/zoning/1101.3 md_url: https://georgiacommons.org/code/local/smyrna/zoning/1101.3.md text_url: https://georgiacommons.org/code/local/smyrna/zoning/1101.3/text source_url: https://library.municode.com/ga/smyrna date: 2026-11-11 status: active jurisdiction: city:smyrna jurisdiction_name: Smyrna place_fips: "1371492" corpus_version: local-codes-smyrna-55e624716b18 publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/code/local/smyrna/zoning/~appendix-b/~article-xi.md previous: https://georgiacommons.org/code/local/smyrna/zoning/1101.2.md next: https://georgiacommons.org/code/local/smyrna/zoning/1101.4.md index: https://georgiacommons.org/code/local/smyrna.md branch: zoning edition: As published by Municode, retrieved 2026-11-11 edition_date_kind: retrieved source_publisher: Municode version_id: local-code:smyrna/zoning/1101.3@2026-11-11-04c2c7ad3e --- # Smyrna Zoning Ordinance, 1101.3. Storm drainage system. The storm > As published by Municode, retrieved 2026-11-11 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Appendix B - SUBDIVISION REGULATIONS / Article XI - REQUIRED IMPROVEMENTS drains along with catchbasins and manholes shall be installed in conformance with the approved plans and specifications, and as indicated herein. (a) Every subdivision shall be served by storm drainage facilities, including drains, sewers, catchbasins, culverts and other facilities, as required by standards and specifications of the city engineer. (b) All drainage facilities shall be so designed to serve that portion of the drainage basin located upstream from the facility. All street drains serving lots in a subdivision shall be installed by the subdivider. (c) All surface water drainage shall be transported to existing storm sewers or to drainage facilities approved by the city engineer. (d) All drainage facilities shall be constructed in accordance with city specifications, and no extension shall be made from street drainage through the abutting property without approval of the city engineer. (e) Whenever drainage ditches are used, such ditches shall retain natural design characteristics and be so designed that they do not present a hazard to life and safety. (f) When the construction of a subdivision street requires the crossing of a drainage channel, the developer shall provide and install the required size and length of an acceptable grade of pipe. The length of the pipe required shall be measured from a point 60 feet to the rear of the required building setback line on the upstream side of the street to a point 60 feet beyond the building setback line on the downstream side of the street, and in no case shall the pipe be less than 30 feet from the rear of any proposed dwelling. In cases where the developer or owner chooses not to develop the land through which the channel passes, then the drainageway may be left open; however, in such cases, the plat shall be so marked and an easement shown thereon, indicating that no building or driveway shall be built over or within 40 feet of the open ditch. Where the developer chooses to leave the drainCDB:20 ageway open and it is crossed by a driveway, the size of the pipe shall be determined by the city engineer, and no building permit shall be approved unless the installation meets the requirements of the city engineer. (g) Development of land subject to flooding shall be governed by the Cobb County floodplain ordinance, unless variance is granted by the mayor and council, after recommendation by the planning commission. All plats and deeds for lots within a subdivision that contain land in a floodplain shall have that fact so noted in the deed and on the plat. (h) Improvements, such as widening, deepening, relocating, clearing, protecting or otherwise improving existing lakes and shorelines, streambeds and other water impoundments or courses for the control of mosquitoes and public health nuisances shall be provided by the developer in accordance with the standards and requirements of the health department. (i) All water impoundmentstructures shall be constructed so as to minimize mosquito breeding and other nuisance hazards. The outside toe of any dam shall be at least 50 feet away from the toe of a street rightof-way slope. Any dam to be constructed within the city shall require the approval of the city engineer and the health department and shall be constructed in accordance with city and health departmentstandards and specifications. (j) Notwithstanding the above controls, the city engineer may refuse to authorize the issuance of a building permit on any lot or lots where the land is subject to flooding or where, in the opinion of the city engineer, the topographic features ofthe property are such that a building could not be properly maintained on the lot.