Smyrna · Zoning Ordinance
Appendix A - ZONING ORDINANCE / Article V - GENERAL PROVISIONS
Sec. 515. Townhome design standards.
About this text
- As published by Municode, retrieved 2026-11-11
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
(515.1) Applicability. These regulations shall apply to all townhome uses, unless specifically exempted herein. Where provisions in this section conflict with the remainder of the city's zoning ordinance, the provisions provided herein shall govern.
(515.2) Purpose and intent. These requirements are intended to regulate the siting and design of townhome projects in pursuit of cohesive design and walkable development patterns. The regulations are intended to define elements of the development that supports both horizontal and vertical articulations and variations among units that provide architectural interest and reinforce high quality design and responsible site development practices to meet the goals and policies of the city's comprehensive plan.
(515.3) Minimum architectural design requirements.
(1) The front façades of townhouse units shall have architectural modulation and
detail that includes features such as varied materials and wall planes, varied roof forms and roof lines, balconies,
porches, bay windows, varied window sizes and shapes, shutters, entrance doors, sidelights, pilasters, varied garage door designs, and other features to provide
visual interest.
(2) Façade materials for each unit may be combined on each façade only horizontally, with the lighter materials above the more substantial materials.
(3) The exterior façade shall be comprised of brick and/or stone materials for a
minimum of two stories for any building elevation visible from a public or private right-of-way. Where architectural projections are structurally limited from masonry cladding, those projections are
permitted to be faced with cementitious lap and shake siding or other similar cementitious products. Molding, windows and doors, and other accents are exempt from this requirement.
(4) The side elevations adjacent to a public or private right-of-way shall be consistent with the front façade in terms of articulation, fenestration, wall openings, proportions, architectural details, materials, and window styles.
(5) Buildings that terminate a view or are located at public or private street intersections should provide distinct and prominent architectural features or
otherwise create a distinctive visual landmark.
(6) Any elevation visible from the public right-of-way may not use cementitious
lap siding.
(7) Any building containing more than three units with common walls must have the
front façade and the roof of each attached unit distinct from the other through
separation, staggering, or offsets in design.
(8) Pitched roofs shall be symmetrically sloped no less than 6:12, except those
roofs for porches and attached sheds may be no less than 2:12.
(9) Low pitch or flat roofs shall be enclosed by a parapet that is a minimum of 42 feet in height, or a greater height as necessary to conceal mechanical equipment.
(10) Dormers shall be roofed with a symmetrical gable or a shed configuration.
There shall be no more than two windows wide and placed no less than two feet from an end gable or party wall.
(11) Each home shall have a two-car garage enclosed with architectural doors. Interior clear space a minimum of 18 feet wide by 22 feet deep is required. Standard panel doors are not permitted. A one-car garage may be allowed if approved by the city
council.
(12) All main entrances to the units should have a porch or stoop facing the street
that is at least six feet in depth and 30 square feet in area.
(13) All townhome units must provide a functional rear patio or deck with a minimum of 50 square feet in area.
(14) The window systems for the townhome units shall be recessed from the façade of the building a minimum of one and threequarters inches. This reveal shall be accomplished through the design of the
window casing reveals and frames.
(15) All mechanical components for the townhome unit shall be located or screened in a manner not to be visible from the
public or private right-of-way.
(515.4) Design elements catalogue. Each townhome unit shall provide a minimum of one feature from each of the following categories:
(1) Private outdoor space.
(a) Front porch (minimum 60 square feet in area).
(b) Front-facing balcony (minimum 60 square feet in area).
(c) Rear patio or deck (minimum 150 square feet in area).
(d) Rooftop terrace (minimum 150 square feet in area).
(2) Architectural projection.
(a) Projection window (bay or bow).
(b) Turret.
(c) Covered balcony or porch.
(d) Alternative approved by the community development director.
(3) Roof element.
(a) Dormers.
(b) Front gable or pediment.
(c) Rooftop terrace.
(d) Varied gable system.
(e) Cornice detailing.
(f) Alternative approved by the community development director.
(4) Unit or façade variation (required when more than five units front on a single
block face).
(a) Change in brick/stone color or a change in masonry material.
(b) Change in window composition.
(c) Projection or recess of an architectural feature that is a minimum of five feet deep or 15 feet tall (used to distinguish and separate façades vertically because of the significance of the projection).
(515.5) Bulk standards.
(1) Setbacks. Setback are based on the residential townhome zoning district under section 801. Setbacks shall be measured for the development as whole as well as the from the interior public or private streets.
(a) Minimum overall development setbacks:
(i) Front: 50 feet.
(ii) Side: 25 feet.
(iii) Rear: 30 feet.
(b) Minimum interior setbacks:
(i) Front:
a. Front-entry townhome: 20 feet from back of sidewalk or the outside edge of the landscape zone if no sidewalk is present.
b. Rear-entry townhome: ten feet from back of sidewalk or the outside edge of the landscape zone if no sidewalk is present.
(ii) Street side: 15 feet from back of sidewalk or the outside edge of the landscape zone if no sidewalk is present.
(c) Setback exceptions:
(i) If the townhomes are designed to front on an existing public right-of-way, the front setback for the overall development may be reduced to 25 feet.
(2) Building separations. Townhome buildings shall maintain the following building separations:
(a) Front to front: 50 feet.
(b) Side to side: 20 feet.
(c) Side to rear: 40 feet.
(d) Rear to rear: 40 feet.
(3) Maximum building height: 45 feet (or three stories).
(4) Minimum floor area per unit: 1,000 square feet.
(5) Minimum unit width: 24 feet.
(6) Lots:
(a) Unit lots shall be rectilinear in form.
(b) Irregular shaped lots are prohibited.
The creation and establishment of spite strips, flag lots or other shape that is not rectilinear in configuration shall be prohibited.
(c) Common improvements. Common improvements shall be located on a stand-alone lot or as part of a lot held in common ownership by the required homeowner's association.
Common improvements include but are not limited to stormwater ponds, open spaces, amenities and private roads or alleys.
(515.6) Live-work units.
(1) Live-work units shall only be allowed in acceptable zoning districts, such as the mixed-use and central business district
zoning districts.
(2) Live-work units shall be owner-occupied mixed-use dwellings that are fire
separated from adjacent units as attached dwellings.
(3) If any, the minimum number of live-work units in a building is two.
(4) Each live-work unit shall contain a minimum of 2,400 gross square feet of which the non-residential component shall be no less than 500 square feet and shall be on the ground floor oriented to the
public or private right-of-way.
(5) The owner-proprietor of the business shall be the occupant of the residential portion of the unit.
(6) An occupational tax certificate shall be required for operation of a business. The business shall not be considered a home
occupation.
(7) The business use or activity shall not employ more than two persons other
than the owner-proprietor.
(8) Permitted business uses in a live-work unit shall be one of the following types:
(9) Professional office, workshop, or design studio (art, architecture, engineering,
jewelry design, real estate, marketing, counseling, etc.).
(10) Professional services (travel agent, hairdresser, nail salon, tanning salon,
music sales or instruction, tutoring, etc.).
(11) Specialty retail sales (newsstand, books, jewelry, clothing, shoes, antiques, confections, coffee/tea, ice cream).
(12) Other similar uses subject to approval of the community development director.
(13) The façade of the live-work unit shall meet the requirements of section 515.3.
(515.7) Site development standards. Townhome developments shall comply with the following site standards:
(1) Use.
(a) A townhome unit shall contain one single-family attached dwelling unit.
(b) Where the applicable zoning district allows a mix of uses, live-work units
are permitted and encouraged. These units shall be planned with the overall development and approved by the city council.
(2) Buildings.
(a) There shall be a maximum of six units per building.
(b) Rear loaded garages:
(i) A minimum of 25 percent of units shall be rear loaded.
(ii) Where the proposed project site is not readily situated to accommodate the percentage of rearloaded units, the community development director or their
designee may consider the following in applying this requirement:
a. Topographical conditions which would require significant adjustments to the natural grade that would result in substantial cut and fill and/or large, expansive retaining walls that would not otherwise be required.
b. Proposed designs for alternative site layout.
(c) Relationship external to the development:
(i) All units fronting on an external public or private street shall face the subject street with the front/primary façade and shall provide access from the interior of the development.
(ii) Driveways for individual units are not permitted to be accessed from streets external to the development.
(3) Driveways.
(a) Driveway length must meet the minimum lengths:
(i) Townhomes with front-entry garages shall provide a minimum driveway length of 22 feet from garage door to back of sidewalk or the outside edge of the landscape zone if no sidewalk is present.
(ii) Townhomes with rear-entry garages shall provide a minimum driveway length of 20 feet from garage door to back of curb.
(b) Reductions in driveway length or the elimination of driveways may be provided if the following conditions exists:
(i) There is adequate on-street parking within the development;
(ii) On-street parking must exceed the minimum requirements for guest parking with the development;
(iii) The covenants for the homeowner's association require the use of the two-car garage for parking and preclude the use of the garage for the storage of personal items; and (iv) The city council must approve all reductions in driveway length.
(c) Driveways for adjoining front-entry units shall be paired together to create larger landscape areas in front of townhome buildings.
(d) End units may utilize side loaded garages and driveways to provide more space for grouped landscaping at each end of the building.
(4) Streets.
(a) All streets within townhome developments shall be accessed through an interconnected network. Cul-de-sac
and other dead-end streets terminating interior to the development are prohibited.
(b) Sidewalks and streetscape elements are required on all streets internal to the development and along all exterior road frontages.
(i) All streets within the development shall provide a five-foot sidewalk with an eight-foot
landscape zone between the back of curb and the sidewalk on one side of the street. The side of the street opposite of the sidewalk shall provide an eight-foot landscape zone measured from back of curb.
(ii) Street trees shall be planted on both sides of all streets within the development within the required landscape zones.
(iii) Street trees shall be planted every 40 to 50 feet on center along all public and private streets within the development.
(c) Streets within a development shall provide the following street widths, as measured from back of curb to back of curb:
(i) Streets shall maintain a minimum width of 26 feet if the vertical distance between the grade plane and the eaves of the highest roof structure of the building along the street exceeds 30 feet.
(ii) Streets shall maintain a minimum width of 22 feet if the vertical distance between the grade plane and the eaves of the highest roof structure of the building along the street is less than or equal to 30 feet.
(d) All streets are required to be developed to public street standards and publicly dedicated, unless developments are proposed to be gated. Streets in gated developments shall be private but are to be developed to public street standards.
The developer shall install and maintain Knox boxes or other public safety equipment required by first responder agencies.
(e) Where the proposed project site is not readily situated to accommodate an interconnected street network, the community development director or their designee may consider the following in applying this
requirement:
(i) Presence of extreme topographical conditions that prevent the feasibility of a crossing based
on floodways or other environmental constraints.
(ii) Availability of adjacent properties to be incorporated into the development to provide
interconnected access based on the age of the structures and/or ripeness for redevelopment.
(iii) Proposed designs for alternative pedestrian connections.
(5) Open space.
(a) Each development shall set aside and program a minimum of five percent of the site as functional open space. In no case shall the open space area be less than 2,000 square feet in area.
(b) Open space may include common amenities, setbacks, planted buffers, parks, and other hardscaped elements and similar features which
are located on private property and owned by the homeowner's association and operated as common space.
(c) A recreation area shall be provided at a ratio of one acre per 50 units (or a proportional percentage thereof) with a minimum of 10,000 square feet provided. Such area shall be developed with at least one passive recreational feature, such as a walking trail, pavilion, gazebo or picnic area, and at least one active
recreational feature, such as a swimming pool, playground or tennis courts. Active recreational areas
must be outside of any floodplain area and located in such a manner that at least 75 percent of the townhouses are within 300 feet, as measured from the building footprints. Any recreation area, whether passive or active, must be located in an area with a slope of less than 15 percent, however, all recreation areas must meet ADA requirements for accessibility. Active recreational areas must be improved through the use of terracing or other techniques to provide a usable area, such that at least 25 percent of the entire recreational area shall have a slope of no greater than three percent.
(d) Areas counted toward open space shall be specifically programmed as active or passive recreation.
(e) Required sidewalks, parking lot landscaping, and other unprogrammed pervious areas shall not be counted toward the open space requirements of this section.
(6) Utilities.
(a) Individual systems for water, electric, fuel/gas, fire suppression and HVAC
shall be required for each unit.
(b) Individual metering shall be provided for water, electric, and fuel/ gas.
(c) Individual utility service lines shall not be located under the driveway of
the unit.
(d) Easements for all utility lines shall be provided in the common ownership area where lateral service connections shall take place.
(7) Parking.
(a) The development shall provide a minimum of two parking spaces per dwelling unit.
(b) In addition to the minimum parking requirements for the district/ use, a minimum of 0.33 spaces per
unit is required to accommodate guest parking within the townhome development. Guest parking count may either be accommodated as common spaces or dedicated to each individual unit.
(8) Mail kiosk.
(a) A centrally located mail kiosk shall be provided within the townhome
development with appropriate ADA access and parking facilities.
(9) Fire protection and accessibility.
(a) Rear access for fire protection.
Townhouse developments shall be designed to provide proper access to all dwelling units for firefighting purposes, as may be determined by applicable codes. Rear access, if required for firefighting purposes may and is encouraged to be accomplished by alleys or access easements.
(10) Common property.
(a) For all developments containing eight units or more, a mandatory homeowners association shall be created and recorded with the county superior court that shall establish
ownership and maintenance obligations for all front yards, common areas and private community
infrastructure including, but not limited to: fencing, landscaping, amenities, stormwater management facilities and buffers, and shall include architectural control oversights for the development.
(b) The development shall be constructed and governed in conformity with the requirements of the Georgia Condominium Act (O.C.G.A. § 44-3-70 et seq.). A declaration of condominium shall be submitted and recorded in compliance of this Act.
(515.8) Zoning application requirements. Any application for a townhome project shall include the following information so a clear and accurate understanding of the proposed project elements can be evaluated during the legislative review process under article XV of the zoning ordinance:
(1) Concept site plan illustrating proposed improvements, facilities, structures,
amenities, lots, and applicable dimensions to demonstrate compliance with zoning regulations.
(2) Conceptual landscape plan to show proposed landscaping along project boundaries, in buffer areas, in the streetscape zone, and landscape as a component of any amenity requirements, at a
minimum.
(3) Area calculations and description of proposed amenities articulated on concept and/or landscape plan.
(4) Concept building elevations that articulate the following:
(a) General architectural style.
(b) Proposed materials, colors, and other details to demonstrate compliance
with minimum design requirements.
(c) Architectural elements proposed to meet the minimum design elements.
(d) Proposed variation between units.
(5) All variances shall be identified and explicitly requested through the process outlined in article XIV.
History
(Ord. No. 2022-21, 9-9-22)
Read this code where it is posted (Municode) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.