The preliminary plat shall show existing ground elevations at no more than five-foot contour intervals, based on sea level datum (or a datum plane approved by the city engineer), and a tie to one or more benchmarks approved by the city engineer. Ground elevations may be based on field surveys or photogrammetric methods from aerial photographs. 801.4. Information to beprovided on thepreliminaryplat. The preliminary plat shall be prepared by a registered engineer, landscape architect or land surveyor and shall depict the following information: (a) Proposed name of the subdivision. (b) Name and address of the owner of record. (c) Name, address and telephone number ofthe subdivider. (d) Dates oftopographic and boundary surveys, north point, graphic scale, source of datum, date of plat drawing and space for revision dates. (e) Location (land lot and district) and gross acreage of tract. (f) Vicinity map showing the location of the subdivision in relation to the surrounding area, with regard to well-known landmarks such as major thoroughfares, railroads or others. Maps may be drawn in freehand and at a scale sufficient to show clearly the information required, but not less than one inch to 2,000 feet (1" = 2,000'). (g) Exact boundary lines of the tract indicated by a heavy line giving bearings and distances. The boundary linesshall include the entire tract to be eventually subdivided, and data as required herein shall apply to the entire tract. (h) Natural features within the proposed subdivision, including drainage channels, bodies ofwater, wooded areas and other significant features. On all watercourses traversing the tract, the direction offlow shall be indicated, and the acreage of the drainage area above the point ofentry shall be noted. Floodplains within the subdivision tract shall be outlined. (i) Existing cultural features located within and immediately adjacent to the proposed subdivision, including right-of-way and pavement widths and the names of existing and platted streets, all easements, city and county lines and other significant features. Location and dimensions of bridges, utility lines, street culverts and other features also should be indicated. (j) Proposed subdivision layout, including lot lines with approximate dimensions, lot numbers, block letters, street and alley right-of-way lines with proposed street names, right-of-way widths, sites reserved through covenants and easements dedicated or otherwise for public uses and any land to be used for purposes other than singlefamily dwellings. (k) Minimum front yard building setback lines. (1) Provisions for water supply, sewage disposal and storm drainage. (m) Location and results of percolation tests for lots which will not be served by a public sanitary sewage system, as required by the health department. (n) Proposed unit division or phase development, if any, as proposed by the subdivider. (o) Present zoning of tract and adjacent land.