Shopping centers are defined as a group of three or more retail stores or shops under single ownership or management or owned individually as condominium unit. Shopping centers are special permit uses in C-2 Districts and shall comply with the requirements of special uses and the following additional standards. The applicant shall submit site plan containing all the relevant information in order for the planning commission and city council to determine that the proposed development meets the requirements of this chapter. (1) There shall be no more than two access points to any one public street. All entrance and exit points shall be located to afford maximum safety to traffic, provide for safe and convenient ingress and egress to and from the site and to minimize conflict with the flow of traffic. (2) Any exit driveway shall be so designed so as to provide the following minimum sight distance measured in each direction. The measurements shall be from the driver's seat of a vehicle standing on that portion of the exit driveway with the front of the vehicle a minimum of ten feet behind the curbline or edge of shoulder with the height of the eye 3.75 feet to the top of an object 4.5 feet above the pavement. Allowable Speed Required Sight Distance 25 160 40 275 45 325 50 350 55 425 (3) Where a site occupies a corner of two intersecting roads, no driveway entrance or exit shall be located within 50 feet of the point of tangency of the existing or proposed curb radius of that site. (4) No part of any driveway shall be located within a minimum of ten feet of a side property line. However, the planning commission/city council may permit a driveway serving two or more adjacent sites to be located on or within ten feet of a side property line between adjacent sites. (5) If the proposed shopping center is adjacent to another shopping or commercial property, the commission/council may require connection of parking areas so as to alleviate use of the public street for traffic movement between properties. (6) Driveways shall intersect the road at an angle of as near 90 degrees as site conditions will permit and in no case less than 60 degrees. (7) The dimensions of the driveways shall be designed to accommodate adequate the volume and character of vehicles anticipated to be attracted daily to the development. The following are the minimum widths: One-way driveways: 15 feet. Two-way driveways: 25 feet. (8) Any driveway shall be constructed with the surface approved by the commission/ council. Such surface shall extend to the paved portion of the road and shall extend throughout the area defined by the required driveway dimensions. (9) Where a driveway serves right-turning traffic from a parking area providing 200 or more parking spaces and the road has an average daily traffic volume exceeding 7,500 vehicles, an acceleration lane and a deceleration lane for each connection is required. Each shall be 200 feet in length and ten feet wide. A minimum 35 foot curb return radius shall be used for each. (10) Parking shall be provided as required in article IV. Parking aisles which provide direct access to individual parking stalls shall be 25 feet wide. All parking shall be 90 degrees (perpendicular) from the aisles. a. Parking areas should be designed to focus on major walkways, which should be fenced or marked. b. Where pedestrians must cross service roads or access roads to reach parking areas, crosswalks should be clearly designed by pavement markings or signs and lighted. Crosswalk surfaces should be raised slightly to be distinguished from driveways, unless drainage problems would result. (11) Exterior lighting shall meet the following requirements: a. The style of the light and the light standard shall be consistent with the architectural style of the principal building. b. The maximum height of freestanding lights shall be no more than 25 feet. c. All lights shall be shielded to restrict the maximum apex angle of the cone of illumination to 150 degrees. d. Where lights along property lines will be visible to adjacent residents, the lights should be appropriately shielded. e. Spotlight-type fixtures attached to buildings are not permitted. f. The following intensity in footcandles should be provided: 1. Parking lots: an average of 1.5 foot-candles throughout; 2. Intersections: Three footcandles; 3. Maximum at property lines: One foot-candle. (12) Buffer and landscaping shall be required as follows: a. Buffers are fences, landscaping, berm and mounds used to minimize any adverse impacts or nuisance on the site or from adjacent areas. Buffers are required where a shopping center abuts a residential use or district. b. Natural plants can be used as buffers, if the existing natural plants are sufficient to block the view of the new shopping center. New plantings can be used if they are of sufficient size and character to substantially block the view of the shopping center from the residential area. c. Landscaping is required for all shopping centers. For each 24 parking spaces there shall be required adjacent to the parking spaces, three canopy trees, two understory trees and six shrubs. d. Unless otherwise specifically indicated by the planning commission, all plant materials required shall meet the following minimum size standards: Canopy tree: 21 /2 caliper. Understory tree: Four feet in height. Shrub: Two feet in height.