--- title: Stockbridge Zoning Ordinance, 15.9.22. Building standards for areas of shallow flooding (AO zones) collection: local-codes id: local-code:stockbridge/zoning/15.9.22 cite_as: Stockbridge, Ga., Zoning Ordinance ยง 15.9.22 canonical_url: https://georgiacommons.org/code/local/stockbridge/zoning/15.9.22 md_url: https://georgiacommons.org/code/local/stockbridge/zoning/15.9.22.md text_url: https://georgiacommons.org/code/local/stockbridge/zoning/15.9.22/text source_url: https://library.municode.com/ga/stockbridge/codes/code_of_ordinances date: 2026-11-14 status: active jurisdiction: city:stockbridge jurisdiction_name: Stockbridge place_fips: "1373704" corpus_version: local-codes-stockbridge-41fbfc65f02e publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/code/local/stockbridge/zoning/~title-12/~chapter-15.md previous: https://georgiacommons.org/code/local/stockbridge/zoning/15.9.21.md next: https://georgiacommons.org/code/local/stockbridge/zoning/15.9.23.md index: https://georgiacommons.org/code/local/stockbridge.md branch: zoning edition: As published by Municode, retrieved 2026-11-14 edition_date_kind: retrieved source_publisher: Municode version_id: local-code:stockbridge/zoning/15.9.22@2026-11-14-2a1ca32612 --- # Stockbridge Zoning Ordinance, 15.9.22. Building standards for areas of shallow flooding (AO zones) > As published by Municode, retrieved 2026-11-14 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Title 12 - UNIFIED DEVELOPMENT CODE / Chapter 15 - ENVIRONMENTAL PROTECTION / 15.9 - Floodplain management/flood damage prevention. Areas of special flood hazard may include designated "AO" shallow flooding areas. These areas have base flood depths of one (1) to three (3) feet above ground, with no clearly defined channel. In these areas, the following provisions apply: A. All new construction and substantial improvements of residential and nonresidential structures shall have the lowest floor, including basement, elevated to no lower than one (1) foot above the flood depth number in feet specified on the flood insurance rate map ("FIRM"), above the highest adjacent grade. If no flood depth number is specified, the lowest floor, including basement, shall be elevated at least three (3) feet above the highest adjacent grade. Flood openings sufficient to facilitate automatic equalization of hydrostatic flood forces shall be provided for floodprone enclosures in accordance with subsection 15.9.18.E; B. New construction and substantial improvement of a nonresidential structure may be floodproofed in lieu of elevation. The structure, together with attendant utility and sanitary facilities, must be designed to be watertight to the specified FIRM flood level plus one (1) foot above the highest adjacent grade, with walls substantially impermeable to the passage of water, and structural components having the capability of resisting hydrostatic and hydrodynamic loads and the effect of buoyancy. A licensed professional engineer or architect shall certify that the design and methods of construction are in accordance with accepted standards of practice, and shall provide such certification to the official designated by the Henry County Board of Commissioners and/or his designee using the FEMA floodproofing certificate along with the design and operation/maintenance plan; and C. Drainage paths shall be provided to guide floodwater around and away from any proposed structure.