The purpose of this section is to determine where age-restricted adult housing may be located and to provide minimum standards. The intent of this section is to encourage age-appropriate housing for persons with mobility, sensory, and cognitive limitations. Though these regulations require that over-all developments feature a measure of accessibility, full accessibility is encouraged. Accessibility is defined by the Georgia Accessibility Code as amended, and any age-restricted adult housing development must meet the same standards required by Georgia Accessibility Code 120-3-20-.54 in order to be considered fully accessible. Senior adult housing may be allowed in the following zoning districts as either the primary use or as a supplemental use, in addition to another permitted use: RR, SR, CCR, and MFR, provided that, at a minimum, the following restrictions apply. Final plats and all required construction documents shall include a notation specifying "Age-Restricted Adult Housing." The development standards for senior adult housing are listed below. Developments must also comply with the districts in which they are located, including any overlay districts. In this section, "senior adult housing" does not include assisted living facilities or nursing homes. A. Unit types allowed: 1. Only single-family detached units may be allowed in RR and SR districts. 2. Only multi-family units may be allowed in CCR and MFR district. B. The development shall have a minimum of twenty (20) dwelling units. C. The maximum net density shall meet the future land use plan requirements. D. At least forty percent (40%) of the gross site area shall be open space. The open space shall provide amenities such as pathways, seating areas, and recreation areas for residents. The open space shall be protective of natural features. E. At least one (1) on-site community building or interior community space shall be provided which contains a minimum of the following heated floor area: 1. Twenty (20) square feet of heated floor area per dwelling unit for the first ninety-nine (99) units with a minimum of five hundred (500) square feet; and 2. Ten (10) square feet of heated floor area per additional dwelling unit. F. For phased development—Open space, recreational facilities, and other accessory facilities shall be provided in each phase to meet the requirements as stated herein of the residents of each phase. The developer shall provide a schedule for the installation of facilities at the time of the first permit approval. G. At the time of the first permit application, the developer shall establish how the age restrictions will be implemented and maintained over time. If the development is anything other than a rental community under single ownership, a common entity such as a condominium association, a homeowners' association, or a property management company shall be established to maintain and enforce the age restrictions in addition to the City of Stockbridge enforcement of zoning regulations. H. The minimum unit size shall be one thousand two hundred (1,200) square feet. I. All open space, common areas, and related improvements shall be fully accessible and shall be managed and maintained by the owner of the development or a common entity such as a condominium association, or a homeowner's association. J. Any structure within the development may be fully accessible; however, the minimum standards of this section shall be met. The development shall incorporate universal design features, as are listed below. The application shall include descriptions of the universal design features of proposed dwellings to demonstrate their appropriateness for the age-restricted population. The material that is submitted shall indicate how universal design features will be used to make individual dwellings adaptable to persons with mobility, sensory, or otherwise functional limitations; and how the design will provide accessible routes between parking areas, sidewalks, the front doors of the dwelling units, and common areas. These routes shall be a minimum of ten (10) feet wide, allowing mobility-enhancing devices to meet and pass safely. 1. "No-step" (maximum vertical floor level change of one-quarter (¼) inch, except where a tapered threshold is used, which has a maximum height of one-half (½) inch access to the front door entrance to all dwelling units and community buildings is required. If a no-step front entrance is not feasible, an alternate no-step walkway to the front floor may be approved. 2. A minimum thirty-six-inch wide front door with exterior lighting at the entrance is required. Exterior doors shall be provided with an artificial light source located in the immediate vicinity of the exterior door. The illumination of the exterior light shall be controlled from inside the dwelling, except for lights that are continuously illuminated or automatically controlled. 3. All interior doorways must have a minimum of thirty-two-inch clear width in the open position—typically a thirty-six-inch door. 4. A thirty-six-inch fully accessible route must connect throughout the floor which is served by the front door of the dwelling unit. The maximum vertical floor level change is one-quarter (¼) inch, except where a tapered threshold is used, which has a maximum height of one-half (½) inch. 5. A complete living area, including, but not limited to, kitchen, master bedroom, and bathroom, shall be located on the floor served by the front door of the dwelling unit. 6. Lever handles are required on all interior and exterior doors. 7. Clear floor space of thirty (30) inches by forty-eight (48) inches shall be provided and centered on each appliance and fixture in the kitchen. Floor space can overlap. 8. Walls shall be reinforced (blocked) to allow for the later installation of grab bars around the toilet, tub, and shower stall; and of wall-hung bench shower seat. 9. Maneuvering space shall be provided within the bathroom to permit a person using a mobility aid to enter the room, close the door, and reopen the door with a clear floor space of thirty (30) inches by forty-eight (48) inches. Clear floor space of thirty (30) inches by forty-eight (48) inches shall be provided and centered on each fixture in the bathroom. Floor space may overlap. 10. Wall-mounted electrical outlets, light switches, and environmental controls shall be mounted for a reaching range of a minimum of fifteen (15) inches to a maximum of forty-eight (48) inches above the floor. Such wall-mounted devices shall be of a contrasting color with the wall.