Skip to content
Georgia Commons
Menu

Stockbridge · Zoning Ordinance

Title 12 - UNIFIED DEVELOPMENT CODE / Chapter 4 - DEVELOPMENT STANDARDS / 4.4 - Architectural guidelines.

4.4.2. Requirements for single-family detached and attached.

About this text

  • As published by Municode, retrieved 2026-11-14
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

These requirements only pertain to buildings that are exclusively residential in nature.

A. Facades.

1. Primary material coverage required, at a minimum, a twenty-four (24) inch course/water table, consisting of brick or stone or a combination of each, measured from where the final grade of the lot meets the outside of the building.

2. Secondary material coverage remaining area may be comprised of one (1) or more of stucco, shake, and/or cement fiberboard siding.

3. Vinyl or aluminum siding shall not be permitted. Metal or cementitious composite board siding may be used in the eaves and soffits of a building.

B. Roof Pitch. The minimum roof pitch of a single-family home shall be 4:12, with the exception of attached patio covers. The minimum roof pitch of an attached patio cover shall be as required by the current State minimum standard codes for construction.

C. Roof Materials. Roof materials shall include wood or cedar shakes, asphalt composition, wood, shingles. Other roof materials may be used where specifically approved by the director.

D. Foundation. The dwelling shall be attached to a permanent foundation. The foundation shall be concrete or masonry blocks joined by mortar or both.

E. Finished Floor. Any building having its finished floor entirely above grade, except for a basement, as defined in the International Building Code, shall be enclosed by masonry blocks or bricks joined by mortar, or poured concrete walls having a minimum height of eighteen (18) inches and a minimum width of six (6) inches.

F. Garages.

1. A minimum of two (2) car garages shall be required for all single-family detached residential structures. Side entry garages should always be considered and constructed when possible.

2. Two (2) car garages are required for townhomes and for each unit of a duplex.

History

The history line the source prints at the end of the section.

(Ord. No. OR25-618, 1, 12-8-2025)

Meetings that refer to this section

Found 2: meetings of this government whose minutes or machine transcripts name this section, or an ordinance in its history line, newest first. Found by rule from those records' own words. A reference is a pointer to another record, not a statement that the section applies or was changed.

Read this code where it is posted (Municode) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.

Version local-code:stockbridge/zoning/4.4.2@2026-11-14-78cb65cb19

The assistant can say what this section says in this edition, quoting it and linking to it. It will not apply the law to your situation, and nothing here is legal advice.

Stockbridge Zoning Ordinance, 4.4.2. Requirements for single-family detached and attached | Georgia Commons