In addition to all other regulations in this article, all signs must conform to the requirements and the tables which are contained in this section. A. All signs shall be required to be located within the required front yard of a principal structure and shall not be permitted to extend beyond the front property line into the street right-of-way. The location of signs shall not interfere with the view of a traffic signal or traffic vision. For traffic safety, signs shall not be located within the triangular area on a corner lot formed by measuring fifteen (15) feet along both street side property lines from their intersection. B. In order to erect a second wall sign, a use must have frontage on two (2) publicly dedicated streets (such as on a corner lot), with each street, including a legal curb cut, or be located within an end unit of a building on any lot. C. In order to erect a second monument/freestanding sign there must be a minimum lot area of one (1) acre to permit a second such sign to be erected. In those instances where one (1) of the street frontages is on a street serving a residential district, a second sign shall be prohibited. D. Lots zoned RR, SR, CCR, and MHR (where a single residence is on the lot) and MFR (where a single residence is on the lot). 1. The total of all signs shall not exceed four (4) signs of any allowed type per residential lot; 2. The following signs are prohibited, along with the prohibited signs designated in Section 5.5: a. Projecting signs; b. Awning signs; c. Changeable copy signs; d. Monument signs (except when used as subdivision entrance sign); and e. Wall signs. Table 5.11(A): Sign Requirements for RR, SR, CCR, MHR, and MFR Zoning Districts Sign Requirements | Window Sign | Temporary | Subdivision Entrance Sign Max height | None | 3' | 6' Max width | None | None | None Max sq. ft. of signable area | 4 | 4 | 32 Total aggregate of all signs | 16 | 16 | None Max number of signs per lot | 2 | 4 | 1 per entrance Required minimum setback from right-of-way | None | 1' | 6' Required minimum setback from electrical transmission lines | None | None | 10' E. Multi-Family Residential Lots Zoned RM. 1. The total aggregate signable area allowed per lot must not exceed sixty-four (64) square feet. 2. The following signs are prohibited, along with the prohibited signs designated in Section 13.5: a. Projecting signs; b. Wall signs; and c. Changeable copy signs. Table 5.11(B): Sign Requirements for Multi-Family Residential Lots Zoned RM Sign Requirements | Window Sign | Temporary Sign | Monument Entrance Sign Max height | None | None | 6' Max width | None | None | None Max sq. ft. of signable area | 4 | 16 total (aggregate of all signs) | 32 Total aggregate of all signs | 16 | 16 | None Max number of signs per unit | 2 | 2 | 1 per entrance Required minimum setback from right-of-way | None | None | 5' Required minimum setback from electrical transmission lines | None | None | 10' F. Commercial Lots Zoned C-1, C-2, and C-3 with Multiple Business Per Lot or Business Subdivision. 1. One (1) principal freestanding sign is permitted per lot. 2. One (1) wall sign is permitted per primary exterior entrance for each business or building per street-frontage. Businesses without a street on which there is frontage, but which have exterior entrances to the building, are entitled to one (1) wall sign on the exterior wall of the business where the primary entrance is located. For corner lots, a second wall sign may be permitted facing the side street. End units of buildings on any lot may also have a second wall sign on the side of the building. 3. The following signs are prohibited, along with the prohibited signs designated in Section 5.5: a. Pole or pylon signs; and b. Roof signs. 4. All panels in multi-tenant monument signs must have equal signable area. Table 5.11(C): Sign Requirements for Commercial Lots Zoned C-1, C-2, and C-3\ (Multiple Business Per Lot or Business Subdivision) Sign Requirements | Monument/ Freestanding Sign | Projecting Sign | Wall Sign | Temporary Sign | Window Sign | Awning Sign Max height | 8' | None | None | 8' | None | 18" lettering Max width | None | None | None | 8' | None | Building width Max sq. ft. of signable area | 1 sq. ft. per linear foot of building frontage up to 64 sq. ft. | 24 | Not to exceed the smaller of 10% per tenant wall area or 100 sq. ft. | 32 total (aggregate of all signs) | 25% of the area of each window in which a sign is placed | 10% of awning space Max number allowed | 1, except 2 if permitted by Subsection 5.11(C) | 1 per tenant, per street frontage | 1 per primary exterior entrance | 2 | 3 | 1 per tenant, per street frontage Required minimum setback from right-of-way | 5' | None | None | 5' | None | None Required minimum setback from electrical transmission lines | 10' | 10' | None | 10' | None | None Max projection from wall | None | 6' | None | None | None | None G. Commercial Lots Zoned C-1, C-2, and C-3 with Single Business Per Lot. 1. Each lot is permitted one (1) principle freestanding sign and one (1) wall sign for each street-facing wall. 2. The following signs are prohibited in this district, along with the prohibited signs designated in Section 13.5: a. Pole or pylon signs; and b. Roof signs. Table 5.11(D): Sign Requirements for Commercial Lots Zoned C-1, C-2, and C-3\ (Single Business Per Lot) Sign Requirements | Monument/ Freestanding Sign | Projecting Sign | Wall Sign | Temporary Sign | Window Sign | Awning Sign Max height | 8' | None | None | 8' | None | 18" lettering Max width | None | None | None | 8' | None | Building width Max sq. ft. of signable area | 1 sq. ft. per linear foot of building frontage up to 64 sq. ft. | 24' | Not to exceed the smaller of 10% per wall area or 100 sq. ft. | 32 total (aggregate of all signs) | 25% of the area of each window in which a sign is placed | 10% of awning space Max number allowed | 1, except 2 if permitted by Subsection 5.11(C) | 1 | 1 per primary facade, 1 per secondary facade | 2 | 3 | 1 Required minimum setback from right-of-way | 1' | None | None | 1' | None | None Required minimum setback from electrical transmission lines | 10' | 10' | None | 10' | None | None Max projection from building | None | 4' | None | None | None | None H. Industrial Lots Zoned LI and HI (Multiple Businesses per Lot or Business Subdivision). 1. One (1) principal freestanding sign is permitted per lot, except as allowed per Subsection 5.11(C). 2. One (1) wall sign is permitted for each business per street-frontage. Businesses without a street on which there is frontage, but which have exterior entrances to the building, are entitled to one (1) wall sign on the exterior wall of the business where the primary entrance is located. For corner lots, a second wall sign may be permitted facing the side street. End units of buildings on any lot may also have a second wall sign on the side of the building. 3. The following signs are prohibited in industrial districts, along with the prohibited signs designated in Section 13.5: a. Changeable Copy Signs. Table 5.11(E): Sign Requirements for Industrial Lots Zoned LI and HI\ (Multiple Business Per Lot or Business Subdivision) Sign Requirements | Monument/ Freestanding Sign | Wall Sign | Temporary Sign | Window Sign | Awning Sign Max height | 8' | 8' | None | 18" lettering Max width | None | None | 8' | None | 50% of Building width Max. sq. ft. of signable area | 1 sq. ft. per linear foot of building frontage up to 64 sq. ft. | Not to exceed the smaller of 5% per tenant wall area or 150 sq. ft. | 32 total (aggregate of all signs) | 25% of the area of each window in which a sign is placed | 10% of awning space Max number allowed | 1, except 2 if permitted by Subsection 5.11(C) | 1 per tenant, per street frontage | 2 | 3 | 1 per tenant, per street frontage Required minimum setback from right-of-way | 5' | None | 5' | None | None Required minimum setback from electrical transmission lines | 10' | None | 10' | None | None I. Industrial Lots Zoned LI and HI (Single Business Per Lot). 1. Each lot is permitted one (1) principal freestanding sign, except as allowed per Subsection 5.11(C) and one (1) mounted sign for each street-facing wall. 2. The following signs are prohibited in this district, along with the prohibited signs designated in Section 5.5: a. Changeable copy signs. Table 5.11(F): Sign Requirements for Industrial Lots Zoned LI and HI\ (Single Business Per Lot) Sign Requirements | Monument/ Freestanding Sign | Wall Sign | Temporary Sign | Window Sign | Awning Sign Max height | 8' | None | 8' | None | 18" lettering Max width | None | None | 8' | None | 50% of building width Max sq. ft. of signable area | 1 sq. ft. per linear foot of building frontage up to 64 sq. ft. | Not to exceed the smaller of 5% wall area or 150 square feet | 32 total (aggregate of all signs) | 25% of the area of each window in which a sign is placed | 10% of awning space Max number allowed | 1, 2 if permitted per Subsection 5.11(C) | 1 per street frontage | 2 | None | 1 Required minimum setback from right-of-way | 5' | None | 5' | None | None Required minimum setback from transmission lines | 10' | None | 10' | None | None J. Office and Institutional Lots Zoned OI. 1. One (1) principle freestanding sign is permitted per lot, except as allowed per Subsection 5.11(C). a. One (1) wall sign is permitted per primary exterior entrance for each business or building per street-frontage. Businesses without a street on which there is frontage, but which have exterior entrances to the building, are entitled to one (1) wall sign on the exterior wall of the business where the primary entrance is located. For corner lots, a second wall sign may be permitted facing the side street. End units of buildings on any lot may also have a second wall sign on the side of the building. 2. The following signs are prohibited in this district, along with the prohibited signs designated in Section 5.5: a. Changeable copy signs. Table 5.11(G): Sign Requirements for Office Institutional Lots Zoned OI Sign Requirements | Monument/ Freestanding Sign | Projecting Sign | Wall Sign | Window Sign | Awning Sign | Temporary Sign Max height | 8' | None | None | None | 10" lettering | 8' Max width | None | None | Building width | None | Building width | 8' Max sq. ft. of signable area | 32 sq. ft. | 10 sq. ft. | Not to exceed the smaller of 5% of the wall area or 100 sq. ft. | 25% of the area of each window in which a sign is placed | 10% of the awning space | 32 total (aggregate of all signs) Max number allowed | 1, 2 if permitted per Subsection 5.11(C) | 1 per street frontage | 1 per street frontage | 3 | 1 per street frontage | 2 Required minimum setback from right-of-way | 5' | None | None | None | 1' | None Required minimum setback from electrical transmission lines | 6' | None | None | None | None | None Max projection from building | None | 4' | None | None | None | None K. Planned Unit Developments. 1. Master Sign Plan. The intent of the master sign plan is to promote consistency among signs within a development and enhance the compatibility of signs with the architectural and site design features within a development. 2. Approval Required. Approval of a master sign plan shall be required as part of the development review process in any district that is zoned 'PUD' (Planned Unite Development). All signs that are erected or maintained shall conform at all times to the approved master sign plan. The signs which are approved through the master sign plan are the only signs that are allowed; any deviations from an approved master sign plan shall be unlawful unless and until a revised master sign plan is approved. 3. Master Sign Plan Application. An application for a master sign plan shall include the following information: a. All information as outlined in Section 5.3 of this article; b. Accurate site plan, including location of buildings, parking lots, driveways, and landscaped areas; c. An accurate indication of the location of each present and proposed future sign of any type, whether requiring a permit or not; d. An elevation drawing or photo depicting the proposed location of signs on buildings, walls or windows; e. Computation of the maximum total sign area. For buildings with two (2) or more separate businesses, computations shall identify the total maximum area each individual business will be allowed; f. Plans, including window signage should indicate the areas of the windows to be covered; g. Master sign plans must be signed by all owners or their authorized agents. 4. Master Sign Plan Review. An application for a master sign plan shall be reviewed as part of the development review process. 5. Individual Sign Permits. Individual sign permits are required for all signs contained within an approved master sign plan. 6. Amendments. A master sign plan may be amended by filing a new master sign plan application that conforms to all requirements in this section. 7. Significant Development Exceptions. An exception for one (1) additional freestanding sign may be granted under the master sign plan for significant developments which meet at a minimum all criteria set forth below: a. The development is located on a single tract, parcel, or lot; b. The parcel is to be used for commercial; c. The tract size is a minimum of fifteen (15) acres and the primary frontage of the lot is at least five hundred (500) linear feet or more; and d. The lot has two (2) or more entrances on the street on which it has its primary frontage. 8. One (1) maximum sixty-four (64) square foot monument sign along the primary frontage may be substituted for two (2) single-faced freestanding signs not to exceed thirty-two (32) square feet and six (6) feet in height. L. Master Sign Plan for Multi-jurisdictional Developments. The intent of the master sign plan for multi-jurisdictional developments is to promote consistency among signs within a development that is situated within the City of Stockbridge and one (1) or more other municipalities or the unincorporated areas of a county and enhance the compatibility of signs with the architectural and site design features within such development. 1. The director may authorize a master sign plan for a development that is situated within the City of Stockbridge and one (1) or more other municipalities or the unincorporated area of Henry County. All signs erected or maintained shall conform at all times to the approved master sign plan. The signs approved through the master sign plan are the only signs allowed; any deviations from an approved master sign plan shall be unlawful unless and until a revised master sign plan is approved by the city council. 2. Master Sign Plan Application. An application for a master sign plan for a multi-jurisdictional development shall include the following information: a. All information as outlined in Section 5.3 of this article; b. Accurate site plan, including location of buildings, parking lots, driveways, and landscaped areas; c. An accurate indication of the location of each present and proposed future sign of any type, whether requiring a permit or not; d. An elevation drawing or photo depicting the proposed location of signs on buildings, walls or windows; e. Computation of the maximum total sign area. For buildings with two (2) or more separate businesses, computations shall identify the total maximum area each individual business will be allowed; f. Plans, including window signage should indicate the areas of the windows to be covered; g. Master sign plans must be signed by all owners or their authorized agents. 3. The master plan may include standards for signs which deviate from the general standards provided for herein so long as each jurisdiction approves the same master plan. 4. Individual Sign Permits. Individual sign permits are required for all signs contained within an approved master sign plan. 5. Amendments. A master sign plan may be amended by filing a new master sign plan application that conforms to all requirements in this section.