1. Survey site plan required shall include the following: name and address of owner, vicinity map, with a minimum scale - 1" = 100', north arrow, numbered lots, lot numbers, size of lots, street layout, trash container(s) location, location of all utilities including sewage, unless originally approved with site plans - accessory building or additions to manufactured housing units allowed.
2. Access roads within manufactured housing unit parks shall not be less than 20 feet and shall be paved with a hard surface treatment.
3. There shall be established and maintained guest parking facilities at a ratio of one space per three manufactured housing unit spaces. If access roads are paved to a width of 32 feet, guest off-street parking spaces shall not be required.
4. Each manufactured housing unit space shall be equipped with a pad ten feet for a single-wide, 20 feet for a double-wide by 45 feet long of six inches of compacted gravel or other similar material.
5. Each manufactured housing unit space shall be furnished with connections to water, sewer or septic (tank), and electricity utilities; and all will be approved by the appropriate department/agency.
6. Manufactured housing units may not be used for nonresidential use within manufactured housing unit park except for the manufactured housing unit park office.
7. Standards for manufactured housing unit shall also apply to the latest edition of the Council of American Building Officials (CABO) One and Two Family Dwellings (Code).
8. No owner of a manufactured housing park shall allow a manufactured housing unit to locate or relocate within the park without a location placement permit from the county inspector's office and proof of tax paid.
9. An approved trash container(s), to be compatible with Talbot County's sanitation service, shall be located within 150 feet of any manufactured housing unit park and shall be screened by a solid opaque fence of adequate height to screen from view any material in the container. Such trash containers shall be provided by the manufactured housing unit park owner/operator.
10. All owners, operators of said manufactured housing park shall be responsible for the upkeep of all drives (access roads) within the confines of said park; and the grounds shall be clear of all litter, trash, garbage, inoperable automobiles, trucks, etc. as well as maintaining grounds (cutting of grass, maintenance of other landscaping), and drainage to assure a clean, habitable and sanitary environment.
11. It shall be the responsibility of the owner/manager of said manufactured housing parks to not rent, lease, or otherwise convey the use of property within confined said manufactured housing park until proper permits have been issued by the Talbot County Building Official for said location. A registration shall be required to be kept on premises of all lots rented, leased, or otherwise conveyed to include date, name, address, phone, lot number, size and model.
12. A buffer evergreen strip of at least 25 feet in width and ten feet in height shall be planted along the side and rear yards lines of the manufactured housing unit park.
13. Skirting. All manufactured housing units shall have suitable skirting between the base of the unit and the ground. This skirting shall be made of either concrete block, brick, wood, or other materials intended for such use.
Openings in the skirting shall not be more than two inches square.
14. Access doors. All units shall have a minimum of an 18" x 24" latchable access door and required crawl space venting.
15. Anchors. All units shall be provided with anchors as required by the latest published edition of the CABO One and Two Family Dwelling Code.
16. Inspection. Before electric service is given any manufactured housing unit, the unit and the lot upon which it is located shall be inspected by the Talbot County Building Official after the necessary permits are approved, and all other requirements of this ordinance and other laws, and codes, affecting said location are met.
17. Travel trailers. Manufactured housing unit space shall not be used for the permanent accommodation of travel trailers or recreational vehicles under any circumstances.
18. Age of units. The manufactured housing unit to be placed must be certified under the U.S. Department of Housing and Urban Development and as applicable by the Georgia State Fire Marshal's Office and manufactured after June 15, 1976 prior to issuance of a permit.
8.5. Detailed regulations for PUD planned unit development district. The regulations established for this district are intended to provide optional methods of land development with provisions for residential, commercial, religious, educational and cultural facilities, which are integrated with the total project by unified architectural and open space treatment.
8.5.1. Permitted uses. Single-family attached and detached dwellings; duplexes; multifamily dwellings; condominiums and townhouses; uses permitted in the C-1 district and CORD districts; educational uses; and other religious and cultural uses.
8.5.2. Preliminary development plan. A person applying for a zoning amendment to establish a PUD district shall submit a preliminary development plan to the planning commission, consisting of:
1. A site plan showing:
a. The direction of north, appropriate scale and topography.
b. The location of subject property in relation to the entire county.
c. The use of the property adjacent to the site.
d. The proposed use of land and density of development for the site.
e. Proposed access to, and traffic circulation within, the site.
2. A proposed development schedule for the project.
3. The planned development shall be located in an area for which public facilities and services are available and adequate for the uses that are proposed; provided, however, that the applicant may provide such facilities which are not presently available, and written assurance of such provision shall be included as a part of the preliminary development which is submitted.
4. The planning commission and board of commissioners shall review and act on the proposed zoning request and any amendment to an approved preliminary development plan in accordance with the zoning ordinance.
8.5.3. Final development plan. Prior to the removal of natural vegetation, restructuring of the land or construction of any improvements, an approved final development plan is required. A plan shall be submitted to the planning commission, which is consistent with the preliminary development plan, and containing:
1. A site plan showing:
a. The direction of north, appropriate scale and topography in not greater than five foot contour intervals.
b. The proposed location and height of all structures.
c. The use of all structures and land.
d. The location and use of structures adjacent to the site.
e. The location, area and number of parking spaces and maneuvering areas.
f. The location and dimensions of streets, driveways, and walks on and off the site.
g. All service and loading areas and spaces.
h. The location, size, number and character of all exterior signs and lighting.
i. The location, character and extent of existing vegetation landscaping, retaining and screen walls and other treatment for the protection of adjoining property.
j. The facilities for surface drainage of the premises.
k. Location and character of all public improvements including utilities.
2. A copy of any deed restrictions to be recorded.
3. A comprehensive traffic analysis indicating the probable effect of the proposed development on traffic patterns and capacities of adjacent streets in the immediate area, prepared by a registered engineer or professional planner.
4. A development schedule indicating the appropriate date when construction of the planned development or stage thereof can be expected to begin and be completed.
5. Any other information necessary to establish compliance with this and other ordinances of the availability of adequate utility capacity.
6. A fire protection plan, approved by the volunteer fire department servicing the area, indicating the location and size of all proposed fire mains, fire hydrants, and fire access lanes, as well as a description of all fire protection measures and devices for structures.
7. The public improvements included in the final development plan shall be consistent with the Talbot County Subdivision Regulations. Compliance with said regulations shall be reviewed as part of the final development review process.
8. The applicant shall provide for and/or establish an organization or other legal entity for the control and maintenance of any common open space designated on the final development plan. Such organization shall be created by covenants running with the land, and such covenants shall be included as a part of the final development plan(s) and subject to the approval of the Talbot County Board of Commissioners.
9. Structures and open space shall be arranged in such a way as best to serve the needs of residents and commercial users of the planned development, and to minimize any adverse effects on the neighboring districts.
10. Scenic assets and natural features, such as trees, streams, and topographic features, shall be protected and preserved to the greatest extend possible.
11. Not more than 50 percent of the gross tract area shall be covered by buildings in the PUD.
12. At least 50 percent of the area remaining after the development of the buildings, parking, right-of-way, and utility or drainage easements, shall be developed to serve the needs of the residents of the development; including but not limited to landscaping, patios, walks, play areas, recreation, and other uses consistent with the character of the PUD.
13. Buffers and building set-backs shall recognize and honor existing adjacent land development. However, in no case shall a building be constructed closer than 15 feet from the PUD district boundary, nor 50 feet from any public road right-of-way.
14. Adequate screening and separation between different land uses shall be provided by means of buffering or other acceptable methods.
15. Vehicular access to the PUD shall be from streets capable of supporting existing and projected traffic. No streets or roads within the PUD shall connect to the public street system in such a way as to encourage use of minor streets for through streets.
16. The PUD shall include provisions for safe and convenient pedestrian access and circulation.
Read this code where it is posted (Municode) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.