Such standards as minimum floor area, maximum
number of units per building, exterior finish materials, and facade design shall apply to all multifamily developments contemplated by this section:
A. Maximum density. Maximum density for multifamily developments, defined for purposes of this section to be apartment buildings, shall be 12 dwelling units per acre.
B. Maximum number of units per building. The maximum number of units per building applicable to apartment building developments shall be eight or a maximum building length of 192 linear feet.
C. Facade material design. The use of contrasting exterior finish materials shall be required sufficient to add visual interest. The mix of siding types shall be consistent and proportional on all building elevations.
D. Building exterior finish materials. Building exterior finish materials shall consist of full-sized brick, natural wood, natural stone, cement composite stone, true hard-coat stucco, fiber cement siding (Hardie board) and vinyl siding. Vinyl siding shall have a minimum, nominal thickness of 0.04 inches and shall be installed according to the manufacturer's specifications. Synthetic finishes complying with "Dryvit" standards and acceptable to the city may be allowed. Other materials similar in appearance and composition to the above materials may be used, subject to approval by the building official. Metal siding, concrete block, synthetic stucco, plywood, T1-11 wood siding, Masonite, particle board, non-cement composite board and any siding materials found to lack durable characteristics shall be prohibited.
E. Minimum dwelling unit floor area. The minimum floor area for condominiums and townhouse development shall be as follows:
1. One-bedroom units: 576 square feet.
2. Two-bedroom units: 864 square feet.
3. Three-bedroom units: 1,008 square feet, plus an additional 144 square feet for each additional bedroom.
F. Maximum building height. Maximum building height applicable to apartment building developments shall be four stories, provided that any building exceeding three stories in height shall require approval by the city fire chief.
G. Distance between buildings. Buildings erected front face to front face, back face to back face, or front face to back face shall be not less than 60 feet apart. Buildings erected side face to side face shall not be less than 20 feet apart. Buildings erected side face to front face or back face shall be not less than 40 feet apart.
98-4.5.2.4. Accessory uses and buildings. The following uses and buildings shall be allowed as accessory to the principal residential use of the property.
A. Customary home occupations, including the offices of physicians, dentists, lawyers, artists, musicians, architects, and engineers, subject to the standards of subsection 98-5.4.2, home occupations.
B. Detached garages may be allowed in multifamily developments, subject to the height and setback standards of the principal buildings.
C. Private swimming pools.
98-4.5.2.5. Special uses. The following uses may be allowed, subject to approval of a special use by city council:
A. Boarding and rooming houses.
98-4.5.2.6. Dimensional standards. The following standards shall apply to residential development in the M-R multifamily residential district:
Table 4.7 M-R Multifamily Residential District Dimensional Standards Standard M-R district
Minimum tract area for apartment buildings 10,000 square feet Minimum lot frontage for apartment buildings 100 feet Minimum lot width at the building line 100 feet Minimum front yard setback 20 feet Minimum side yard setback1 5 feet Minimum street side setback 7 feet Minimum rear yard setback 25 feet Maximum lot coverage 50% Minimum heated floor area See subsection 98-4.5.2.3.E., building standards Maximum building height 40 feet
Minimum open space2 Passive: 15% Useable: 10% 1 Side yard setback shall be 30 feet when abutting single family detached development.
2 Usable open space is defined as undeveloped areas dedicated to open space that provide frails and pedestrian amenities as opposed to simply wooded areas.
98-4.5.2.7. Dimensional standards. The following standards shall apply to duplex, triplex and quadruplex developments:
Table 4.8 Dimensional Standards Applicable to Duplexes, Triplexes and Quadruplexes Dwelling
type Maximum density Minimum lot width Minimum floor area Front yard setback Side yard setback Rear yard setback Max. lot coverage Max.
height Duplex 4 units/ acre 68 feet 600 s.f. 20 feet 10 feet 25 feet 40% 35 feet Triplex 6 units/ acre 100 feet 600 s.f. 20 feet 10 feet 25 feet 45% 35 feet Quadruplex 8 units/ acre 85 feet 600 s.f. 25 feet 10 feet 25 feet 50% 40 feet 98-4.5.2.8. Building standards applicable to duplex, triplex and quadruplex development.
The standards of subsections 98-4.5.2.3, building standards, paragraphs C, D, and G shall apply to such developments.
History
(Ord. No. 1166, § 1(Exh. A), 4-5-22)