--- title: Thomasville Zoning Ordinance, Sec. 22-211. Standards for commercial buildings collection: local-codes id: local-code:thomasville/zoning/22-211 cite_as: Thomasville, Ga., Zoning Ordinance § 22-211 canonical_url: https://georgiacommons.org/code/local/thomasville/zoning/22-211 md_url: https://georgiacommons.org/code/local/thomasville/zoning/22-211.md text_url: https://georgiacommons.org/code/local/thomasville/zoning/22-211/text source_url: https://library.municode.com/ga/thomasville/codes/code_of_ordinances date: 2026-10-20 status: active jurisdiction: city:thomasville jurisdiction_name: Thomasville place_fips: "1376224" corpus_version: local-codes-thomasville-4ffe2e5f91c5 publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/code/local/thomasville/zoning/~part-ii/~chapter-22/~article-vii.md previous: https://georgiacommons.org/code/local/thomasville/zoning/22-210.md next: https://georgiacommons.org/code/local/thomasville/zoning/22-212.md index: https://georgiacommons.org/code/local/thomasville.md branch: zoning edition: As published by Municode, current through 2026-10-20 edition_date_kind: current_through source_publisher: Municode version_id: local-code:thomasville/zoning/22-211@2026-10-20-0601671c77 --- # Thomasville Zoning Ordinance, Sec. 22-211. Standards for commercial buildings > As published by Municode, current through 2026-10-20 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Part II - CODE OF ORDINANCES / Chapter 22 - ZONING / Article VII - DISTRICTING STANDARDS Architectural styles should be consistent with the character of architectural styles found within the city as listed in the city commercial design guidelines, to the extent deemed applicable by the board of architectural review and zoning appeals. The following architectural standards shall be applied to all new commercial buildings within the city, excluding designated industrial areas, and shall be applied to development and redevelopment: (1) Exterior finish material on every facade facing a public right-of-way and 30 percent on the remaining facades shall be limited to stone, brick, stucco, synthetic stucco, pre-cast concrete, clapboard siding, textured block, and wood shingles. (2) No blank facades are permitted for all facades facing a public right-of-way. All building facades facing a public right-of-way shall have glazed areas or areas of glazed appearance and openings of at least 20 percent and no more than 75 percent of the facade area. The planning department is authorized to allow a variance up to five percent of the required glazed, glazed appearing, and opening facade area. The glazed, glazed appearance areas and openings shall meet the following requirements: a. Storefronts shall be directly accessible from the sidewalk and shall have glazed areas no more than ten feet from the ground, equal to a maximum of 75 percent of its primary facade area. b. Windows shall be recessed a minimum of two inches from the exterior face of the facade except when clapboard siding is used on the facade. c. Multiple windows in the same rough opening shall be separated by a minimum of a two-inch wide post and sit on one continuous sill. d. All visible building facades shall have a typical window. It is recommended that the typical window be rectangular and vertically oriented or square in proportion, but may include side or fan lights. Once a typical window is designated, any window, which is not typical shall be considered an accent window. The primary facade shall have no more than three accent windows. All other visible facades may have up to five accent windows. An accent window may not be larger in area than four times a typical window. Sidelights and fanlights abutting a door shall not be considered as separate windows. e. If shutters are used, they shall be sized to match the opening, and be provided for all windows on a given wall. f. If security bars are used, they shall be located on the interior of the structure and designed in such a manner so they appear as muntins in a divided light window. Mesh and chainlink are not permitted to cover openings. (3) Mechanical systems, backflow preventers, television antennas, satellite dishes and communication devices shall be screened from view by landscaping or built elements designed as an integral part of the building architecture. (4) Any building constructed as "new development" or "redevelopment," as that term is defined in section 22-6, is required to have a symmetrical pitched roof with a slope of no less than five to 12. Any building constructed as "new development" or "redevelopment," as that term is defined in section 22-6, which utilizes a barrel tile roof shall have a symmetrical pitch of no less than three to 12. Any building, with the exception of one which utilizes a barrel tile roof, with a roof pitch of less than five to 12, whether new development or redevelopment, shall utilize a parapet or false mansard of no less height than necessary to obscure the roofline from view of the public right-of-way and no more than six feet in height as measured from the bottom of the parapet or mansard or no more than the maximum height as permitted under section 22-210 for the zone in which the building is constructed. (5) Architectural details such as texture, pattern, color, and building form used on the front facade should be incorporated on all visible building facades but does not apply to any facade facing service courts or other areas generally not visible to the public. (6) In order to avoid cookie cutter style buildings and in recognition of the fact that corporations have available a minimum of two design options, individual corporate image architectural design elements and colors shall be incorporated only as secondary elements to the buildings and not as the dominant element. (7) No fencing in any commercial and manufacturing zones shall exceed seven feet in height. A list of approved fencing materials is maintained in the planning department. Chainlink fencing will only be permitted in the rear setbacks and must be coated. (8) All awnings shall be consistent with the architecture of the building. Signs displayed on awnings shall comply with the city commercial design guidelines. (9) To the fullest extent possible, all utility connections, including, but not limited to, electric and phone shall be placed underground. (Code 1991, § 22-182; Ord. No. 07262004-1, § I(22-182), 7-26-2004; Ord. No. 12132004-2, § I, 12-13-2004; Ord. No. 02142005-2, § I, 2-14-2005; Ord. No. 05092005-1, § I, 5-9-2005; Ord. No. 05122005-2, § I, 5-12-2005)