Skip to content
Georgia Commons
Menu

Thomasville · Zoning Ordinance

Part II - CODE OF ORDINANCES / Chapter 22 - ZONING / Article VIII - DEVELOPMENT STANDARDS / Division 2 - PUD PLANNED UNIT DEVELOPMENT

Sec. 22-269. Post-approval requirements.

About this text

  • As published by Municode, current through 2026-10-20
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

(a) Construction plans. Upon approval of a PUD application, the land developer may apply for construction plan approval. Construction plans must be submitted within a two-year period following PUD approval or the PUD authorization shall expire. The construction plan approval process is generally an administrative process. Applications for construction plan approval shall be made in accordance with the building permit approval process identified in this Code.

(b) Site plan. If not submitted and approved as part of the PUD approval process, a site plan is required prior to the issuance of a land disturbance permit or building permit. In addition, a preliminary plat is required to be submitted for review by the planning department if one was not submitted at the time of the PUD approval process. Upon receipt of the site plan and preliminary plat, the city planner shall provide written notice to the applicant regarding the consistency between the site plan, preliminary plat and the concept and development plan. The applicant shall revise the site plan and the preliminary plat if so needed and submit a final plat for approval. If not completed as part of the PUD approval process, a final plat is required prior to issuance of a land disturbance permit or building permit. Plat approval shall follow the process in place established and codified in the city ordinances. The site plan shall be scaled to one inch equals 20 feet and shall:

(1) Be in accordance with the concept and development plan to include stated development standards;

(2) Include all of the information required for the submission of a preliminary and final subdivision plan and/or preliminary and final plat, as set forth in the city land subdivision regulations;

(3) Include a grading plan, showing the existing topography and proposed grading of the site at contour intervals of not more than five feet;

(4) Show water runoff drawings, calculations, and plans for soil erosion and sedimentation control, both during and after construction;

(5) Show existing vegetation, tree line, and other natural features, rock outcroppings, bodies of water and watercourses, and the 100-year floodplain. Retention ponds shall be a decorative water feature associated within the PUD. Water levels within the retention pond shall be kept at minimum depth of four feet and shall include a water circulation feature such as a spraying fountain. Detention ponds shall be a decorative feature integrated into the overall design of the PUD's landscape;

(6) Show location, height, ground coverage, and use of all structures and location and areas of open spaces, parking facilities and areas dedicated to public spaces. Calculations of building coverage, numbers of parking spaces, and areas devoted to open spaces shall also be indicated;

(7) Show all utility service lines, and all easements and rights-of-way, existing or proposed; in PUDs proposed on undeveloped sites, all utilities shall be placed underground;

(8) Show adjacent highways and streets serving the site, noting centerlines, widths of paving, grades, and median break points;

(9) Show the location of all roads, streets, driveways, parking facilities, loading areas, points of access surrounding streets, and pedestrian walks and path ways;

(10) In a statement to the planning and zoning commission prior to the issuance of a building permit, the applicant will provide building plans showing the architectural layout for all floors and architectural elevations for review and approval by the planning department and submittal to the commission should the renderings be inconsistent with the approved concept and development plan;

(11) Show, for each residential structure, the number and type of dwelling units;

(12) Show floor areas of all nonresidential buildings for building permit approval;

(13) Contain a landscaping and screening plan, showing all manmade features and the location, size, and species of all planting materials;

(14) Contain an exterior lighting plan, covering all parking areas, driveways, and pedestrian ways, and including the height, number, and type of fixtures to be installed;

(15) Show the location of the nearest public schools, parks, and other community recreational facilities, indicating the location and use of all land to be dedicated to public use;

(16) Provide documents indicating in detail the manner in which any land intended for common or quasi-public use, but not proposed to be in public ownership, will be held, owned and maintained in perpetuity for the indicated purposes;

(17) If a detailed site plan is one of a number of detailed site plans within a planned development, show how each detailed site plan is related to and coordinated with other detailed site plans;

(18) Contain any additional information which may be required by the commission in order to enable it to evaluate the detailed site plan.

(c) Private restrictions. PUDs shall have private restrictions and covenants established. These restrictions and covenants shall promote the preservation of the unique characteristics of the PUD and shall not be inconsistent with the standards approved at the time of the PUD approval. The developer shall submit to the zoning administrator a declaration of covenants, conditions and restrictions, articles of incorporation and bylaws for the property owners' or homeowners' association prior to the issuance of a certificate of occupancy for any structure. The declaration shall confer membership to the owner of property subject to assessment by the association, provide for voting rights in the association with suggestions for the division of power between the developer and the property owner and provide for maintenance assessments, among other items. For PUDs designed primarily for post-secondary educational use, private restrictions shall at a minimum describe the landscape and building maintenance requirements for the overall site whether or not buildings and spaces are tenant or owner occupied.

(d) Permits and certificates. No building permit or certificate of occupancy shall be issued for a building, structure or use, nor shall any excavation, grading or land disturbance applications be approved, for any PUD that has not been approved in accordance with the provisions of this division.

The city planner shall authorize the issuance of building permits for buildings and structures in the area covered by the approved PUD if they are in substantial conformity with the approved PUD, after improvements are installed in accordance with applicable improvement requirements, and if found to be in conformance with all other applicable regulations. The city planner shall authorize the issuance of a certificate of occupancy for any completed building, structure or use located in the area covered by the PUD if it conforms to the requirements of the approved PUD and all other applicable regulations. After completion of a PUD, the use of land and construction, modification or alteration of any buildings, structures or uses within the area covered by the PUD shall be regulated by the approved development plan for the PUD.

(e) Appeals. Any person aggrieved by an interpretation or decision of the city planner in the administration of this division may file an appeal to the architectural review and zoning appeals board (ARZA) in accordance with this Code. The ARZA board shall hear appeals related to interpretation of this division and shall not hear appeals related to development standards that would change the plans approved by the planning and zoning commission. Under no circumstances shall any development standard approved by the planning and zoning commission be allowed an appeal. All changes to the plans approved by the planning and zoning commission shall be resubmitted to the planning and zoning commission for approval.

(Code 1991, § 22-192) Secs. 22-270—22-286. Reserved.