(a) Block standards. To facilitate connectivity and pedestrian accessibility, the blocks may be further subdivided to provide additional connectivity and shall conform to the following standards:

(1) The average perimeter of all blocks shall not exceed 1,800 linear feet.

(2) Any block face that exceeds 600 feet in length shall have a mid-block pedestrian access of at least eight feet in width.

(3) Dead-end streets and cul-de-sacs shall not be permitted.

(b) Terminated vistas. In order to improve spatial definition and orientation on each street, terminated vistas shall be encouraged using buildings, civic spaces, roundabouts, statues, ornamentation, or natural features. Some required terminated vistas are designated on the special requirements plan.

Figure 1-1: Regulating Plan

(c) Lot frontage. The primary frontage of a lot shall be along one of the following:

(1) A thoroughfare right-of-way;

(2) A thoroughfare with development on one side and a civic space on the other; or

(3) Directly upon a civic space in which there is no thoroughfare located between the primary frontage and the civic space.

(d) Building orientation. Buildings have fronts, sides, and backs and how these relate to one another forms neighborhood character.

(1) Primary façades of every primary building shall be oriented to a front lot line or open space.

(2) The primary entrance of every primary building giving access to a primary use of the property must directly face a street or a public space.

(3) All streets should be faced with the fronts or sides of buildings.

(e) Contextual setback. In order to create consistent front setbacks along a block where buildings are already in existence, any new building may apply the contextual setback. The contextual setback shall be no closer than the closest adjacent building to the public right-of-way, and no greater than the farthest adjacent building to the right-of-way. The area between the closest and farthest adjacent building is the build-to zone.

(1) Where there is no adjacent building set back farther than the generally-applicable front setback, the build-to zone shall be between the generally-applicable setback and the setback of the closest adjacent building to the right-of-way.

(2) Where there is no adjacent building setback closer to the right-of-way that the generally applicable front setback, the build-to zone shall be between the generally-applicable front setback and the farthest adjacent building setback from the right-of-way.

(3) Where there are no adjacent buildings on a block face, then the stated setback shall apply.

(f) Retail frontage requirement.

(1) In areas designated as mandatory shopfront on the special requirements plan, at least one ground floor street frontage of a primary building shall be constructed to accommodate retail or personal service uses when there is a market demand for those uses.

(2) Where there is no market demand, as demonstrated by competent financial and market evidence to the satisfaction of the planning and zoning board, a raised floor for a residential walk-up use may be constructed instead of a space for retail or personal service uses, provided that the design and construction allows for future conversion to retail or personal service use should market demands change.

22-594.2 General street standards. An existing grid of streets exists within the downtown. However there may be a need for additional street connections. The precise location and alignment of new streets may be adjusted to allow flexibility in the design of the site plan; however, the intended purpose and network connectivity of each new street shall not be compromised.

(a) Street standards. Streets shall be in compliance with city subdivision regulations.

(b) Downtown street design. The design of new streets and modifications to existing streets shall adhere to the following requirements:

Some dimensional flexibility is permitted for street types to account for varying right-of-way widths, however they shall be designed to have all the basic functional characteristics including roadway width, on-street parking/curbside flex zones, sidewalks, trails, street trees, and landscaped areas shown for their type, and be appropriately sized for the transect zones in which they are located.

All streets shall connect to other streets. Dead-end streets with cul-de-sacs or T-turnarounds shall not be permitted.

(c) Sidewalks. All streets shall have sidewalks which are a minimum width of six feet, and have a continuous unobstructed path of a width no less than 60 inches. This path shall be unobstructed by utility poles, fire hydrants, benches, street signs, or any other temporary or permanent structures. A shared-use path may take the place of a sidewalk.

(d) Streetscapes.

(1) The design of each streetscape zone, the area between the curb and the building frontage, shall comply with the following dimensions:

a. Frontage zone: two feet.

b. Pedestrian zone: four feet to 12 feet.

c. Buffer zone: five feet to six feet.

d. Curb zone: four inches to nine inches.

(2) Streetscape elements can occur on public ROW, private property, or a combination of both.

(3) Within the downtown core, each property with a street frontage of 50 linear feet or more shall install at least one bench, bicycle rack, planter, trash receptacle, or piece of public art per 50 feet of street frontage or part thereof, unless the city manager or their designee waives that requirement based on expected volumes of pedestrian use, site constraints, or potential maintenance issues. Any items placed in the public right-of-way shall require prior approval of the city to ensure that clear pedestrian passages and public health and safety are protected.

(4) In the downtown general and downtown edge transect zones, if any adjacent lot street frontage includes a tree lawn or planting area between the sidewalk and the curb, a tree lawn or planting area of the same depth from the curb shall be installed across the frontage of the property.

(5) Sidewalk or outdoor cafes are permitted as an accessory use to restaurants in the downtown districts.

22-594.3 Special requirements plans. The special requirements plan designate the following sitespecific standards:

(a) Zero setback build-to-line. A build-to-line designates a zero setback from the front property line that the building's primary façade shall be built upon in order to create a uniform line of buildings along the street. The build-to-line marked on the special requirements plan shall take priority over the more general setback defined in the transect standards.

(b) Mandatory shopfront. A ground floor retail shopfront is required along this lot frontage. See requirements for shopfronts in the general development standards.

(c) Terminated vista location. Designations for mandatory terminated vista location, requiring that the building be provided to mark an important view, assist with wayfinding and add to sense of place.

(d) Local historic districts. Buildings that are within a designated local historic district shall conform to the historic district architectural guidelines.

Figure 2-1: Streetscape Diagram 22-594.4 Special building types. Some automotive-oriented uses and large footprint buildings may be provided to serve the daily needs of residents. The following criteria shall be used to ensure these uses and buildings do not detract from the overall walkability of the neighborhoods. All requirements that apply to a proposed building must be met.

(a) Drive-in or drive-through facility.

(1) A ground-floor shopfront shall face the primary street. All parking shall be located in the rear and accessed from an alley when present.

(2) Drive-through windows shall be located to the side or rear of the building and accessed from mid-block or alleys, where existing. Where no mid-block or alley access exists, access from a street frontage is permitted, but shall not substantially disrupt pedestrian activity or surrounding uses.

Figure 2-2: Special Requirements Plan

(b) Formula business. Thomasville seeks to promote a downtown with attractive retail, merchandising, eating, entertainment and recreation opportunities offering residents and visitors alike a diverse environment for commercial, cultural, civic and social pursuits that are identifiable with the city.

(1) A conditional use permit is required for a formula business in the downtown.

(2) In considering a conditional use permit to a formula business in the downtown, the city shall require that all of the following standards be met:

a. Approval of the formula business establishment will not alter the identity of the downtown in a way which detracts from its uniqueness or contributes to a nationwide trend of standardized downtown offerings;

b. Approval of the formula business establishment will contribute to a diverse and appropriate blend of businesses in the downtown;

c. Approval of the formula business establishment will complement those businesses already in the downtown and help promote and foster the local economic base as a whole.

d. The formula business establishment will be compatible with existing surrounding uses; has been designed and will be operated in a non-obtrusive manner to preserve the community's character and ambiance; and the proposed intensity of uses on the site is appropriate given the uses permitted on the site and on adjoining sites, including but not limited to the following:

1. The size of any individual formula business should be compatible with the existing surrounding building footprints.

2. The street frontage of any individual formula business should be compatible with the existing surrounding buildings.

Figure 2-3: Drive-through special building type site design

3. No drive thru windows shall be permitted except as permitted by subsection 22-594.4(a).

4. The applicant shall submit a plan indicating the provision for rubbish removal, including the dumpster location with proper screening and buffering so that there are not any substantial impacts to abutting properties.

5. There shall not be a substantial impact to the public safety from increased traffic. At the discretion of the zoning board, the applicant may be required to submit a traffic study.

6. There shall not be any impacts to the roadway or abutting properties from the loading area.

(c) Gas station or automobile service. Gas stations should be limited within the downtown. When they are used they should adhere to the urban environment by placing the building toward the street or the corner while the pumps are located to the side or rear of the building.

(1) Only one gas station is permitted per block along a street. Additionally, no more than one gas station may occupy an intersection.

(2) A ground-floor shopfront shall face the primary street and define the frontage of the lot.

(3) All pumps, parking, and drive-through areas must be located behind the shopfront building toward a mid-block location.

(4) A minimum four-foot wall or garden wall shall be provided along the length of any lot line adjacent to a street.

(5) Canopy lights shall be located inside the canopy, and shall not be visible from the street.

Figure 2-4: Gas Station special building type site design

(d) Large footprint buildings. Large footprint buildings are those with footprints greater than 30,000 square feet. Examples may include a grocery store, large-format retailer, or theater. Lots may exceed the dimensions set in the transect zone standards provided such buildings comply with the following provisions:

(1) Habitable frontages (as part of the building or a separate liner building) that provide doors and windows facing the public realm shall be provided along façades that face civic uses or streets.

(2) To encourage use by pedestrians and decrease the need for solely auto-oriented patronage, large-footprint buildings must reinforce the urban character of the neighborhood and shall therefore continue a connected system of walkable blocks/street frontages (including sidewalks and street trees) through the site as part of the design of parking and drive aisles.

(3) Building footprints may not be larger than a single block.

(4) Loading docks, service areas, and trash disposal facilities shall not face streets or civic uses.

(e) Liner buildings. A liner building is a building specifically designed to mask a parking garage or larger structure that cannot comply with the façade transparency requirements from frontage on a public street. Such buildings may be constructed in a manner that they will be separated from adjacent streets (but not alleys) by liner buildings:

(1) Liner buildings must be at least two stories in height with no less than 15 feet in depth;

(2) Liner buildings may be detached from or attached to the principal building or parking garage;

(3) Liner buildings may be used for any purpose allowed on the lot on which they are located except for parking; and

(4) Liner buildings must meet the primary facade transparency requirements.

Figure 2-5: Structured Parking Lot Placement

(f) Civic building. Civic buildings may include, but are not limited to, municipal buildings, religious facilities, libraries, schools, recreation facilities, and places of assembly. The building placement, form, design, and construction of civic buildings should reflect the importance of these buildings within the community and with their function as landmarks in mind. Flexibility in building placement and building form, including any numerical design standard under the codes of the city, may be varied upon a finding that:

(1) The civic building is to be sited in a location of particular geometric importance, such as anchoring a major civic open space or terminating a street vista.

(2) The proposed modification is to allow the proposed civic building to better accomplish the design purposes of this code; and

(3) The proposed flexibility will not be a significant detriment to surrounding properties and the district as a whole.

(4) Building form.

a. The scale of civic buildings should typically be larger than surrounding buildings in order to be more prominent and visible across greater distances.

b. Floor-to-floor heights and architectural details should be proportionately larger than those of private buildings that exist or are anticipated within adjacent blocks.

c. Prominent roof forms and additive elements such as cupolas can visually extend the height of the building.

Read this code where it is posted (Municode) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.

Version local-code:thomasville/zoning/22-594.1@2026-10-20-fafa37cad1

The assistant can say what this section says in this edition, quoting it and linking to it. It will not apply the law to your situation, and nothing here is legal advice.

Thomasville Zoning Ordinance, 22-594.1. General to development | Georgia Commons