Troup County · Zoning Ordinance
Appendix B - LAND USE AND ZONING / Article X - SIGN REGULATIONS
Sec. 10.6. General regulations.
About this text
- As published by Municode, current through 2026-06-16
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
The following standards shall apply unless otherwise specified in this article.
(1) A permit shall be required for the erection, alteration, or reconstruction of any sign unless otherwise noted in 10.5.
Permits shall be issued by the Community Development Department in accordance with the regulations contained
in this article.
(2) Design, material, and maintenance. Any sign not meeting the following provisions
shall be repaired or rebuilt in accordance with the specifications of this article:
(a) All signs shall be designed and constructed in accordance with the applicable provisions of the International Building Code and the National Electrical Code.
(b) The area on private property around the sign on which it is erected shall be properly maintained, clear of brush, trees, and other obstacles, so as to make the sign readily visible.
(c) All burned-out bulbs or damaged panels must be replaced.
(d) All sign copy shall be maintained securely to the face and all missing copy must be replaced.
(e) All signs shall be maintained in good structural condition at all times so that the public and traffic safety are not compromised, and
(f) It shall be the responsibility of the sign owner to maintain and ensure compliance with the provisions of this article.
(3) Permanent signs shall be made of highquality, durable material. Approved materials are metal with a minimum
thickness of six (6) mm, high-density urethane (HDU), or wood. If plywood is to be used, it must have exceptionally smooth and weather-resistant surfaces, such as those with medium-density overlay (MDO) board. Other high-quality materials shall be given consideration, and if of comparable quality and durability, may be allowed at the discretion of the County.
(4) Illumination. No sign shall be illuminated by lights that flash, move, change in
intensity, or turn on intermittently more than once a day, unless it is a permitted automatic changeable copy sign as allowed in subsection 10.8. To prevent glare visible from a public road, street or adjoining property, the beam of any light shall be directed as not to be visible beyond
the sign at which it is directed, and the light source shall not be visible from any point on an adjacent property or land of
the public right-of-way.
(5) Sign message. In any zoning district, any sign, display, or device allowed under
this article may contain any lawful noncommercial or commercial message except as expressly provided herein. No provision of this article shall be construed to allow regulation of signs based on the
content of the sign message.
(6) Measurement of Pole Sign and/or Interstate Sign Height: The height of a pole sign and/or interstate sign shall be equal to the vertical distance from the elevation of the centerline of the roadway at the nearest adjacent dedicated public
road, street, to the highest point of the sign structure.
(7) Measurement of a Ground/Monument Sign Height: The height of a ground/ monument sign shall be equal to the vertical distance from the average grade at the base of the sign to the highest point of the sign structure. Any earthen berms and elevated foundations supporting signs, signposts, or other sign supports shall be included in the height of the sign. The ground shall not be altered
for the sole purpose of providing additional sign height.
(8) Measurement of Sign Area: The area of a sign is calculated by determining the
area of the smallest square or rectangle that encloses the sign face and the structure surrounding the sign face. For example, the pole or base would not be included, but any frame holding the sign face in place would be counted. Only one
(1) face of a multi-face sign structure shall be used in computing the sign area.
Where a single freestanding structure contains multiple individual signs, the sign area shall be the total gross area in square feet of all signs on the structure.
(9) Building signs.
(a) A building sign may not project higher than the wall or surface to which it is attached.
(b) A building sign may not project more than 18 inches from the wall surface unless approved as a hanging or projecting sign.
(c) Changeable copy signs and changing signs are prohibited as building signs.
(10) Freestanding signs.
(a) Freestanding pole signs.
(i) Freestanding signs shall be allowed as accessory uses only.
(ii) Freestanding signs shall be setback at least 15 feet from the curb or edge of pavement of the roadway or two (2) feet behind the right-of-way, whichever is greater.
(iii) No freestanding sign shall be located within 30 feet of the nearest intersecting point of two (2) road or street right-ofway lines.
(iv) Freestanding signs shall be located at least 50 feet from other freestanding signs on the same side of the road.
(b) Freestanding monument signs.
(i) Monument signs located within 100 feet of a public right-ofway shall display the road or street address of the property,
except where the sign is located on property that has more than one (1) road or street frontage and the property address is assigned from a road or street other than the road or street frontage whereupon such sign is erected.
(ii) Road or street numbers shall be of contrasting colors against the background, visible from both directions of travel along the road or street, and no less than six (6) inches nor more than 10 inches in height.
(iii) Monument signs shall have a substantial base with stone, brick, or other compatible material to help give the sign a sense of being permanent,
"anchored," and durable.
(iv) The design details, construction materials, color, and architectural style shall be
consistent with that of the principal buildings on the site.
Signs shall integrate compatible architectural elements on the sides and top to frame the
sign pane(s).
(v) Architectural lines that complement those of the building shall be incorporated, especially with
respect to the top of the sign.
Columns, pilaster, cornices, and similar details can provide design interest and keep the sign in scale with adjacent buildings.
(11) Projecting signs.
(a) A projecting sign shall not project more than 36 inches beyond the wall to which it is attached.
(b) A projecting sign shall be finished on both sides.
(c) A projecting sign shall be mounted perpendicularly to the wall.
(12) Gas Canopy Signs: One (1) company logo shall be allowed per road or street frontage.
(13) Project Entrance Signs. Where permitted, project entrance signs shall meet the following standards:
(a) Each project entrance may have no more than one (1) such sign per entrance if double-faced or two (2) signs if attached to symmetrical entrance structures.
(b) The sign must be constructed of brick, stone, masonry, or equivalent architectural material and be monument-style or integral to walls/ fencing separating the project from
the road street.
(c) The maximum face area shall not exceed 40 square feet.
(d) The height of the structure shall not exceed eight feet including embellishments which shall not extend more than two (2) feet above the
main body of the structure.
(e) Signs shall not be internally illuminated.
(f) Signs shall be located a minimum of 15 feet from the edge of a road or street or two (2) feet behind the right-of-way, whichever is greater.
(14) Miscellaneous Freestanding Signs: Accessory uses on multi-family lots to include manufactured housing parks and commercial recreational vehicle parks, campgrounds, and rental cabins, nonresidential lots and lots with public and institutional uses, subject to the following regulations:
(a) Within the area between a road or street right-of-way line and the minimum building setback required from that road or street right-ofway line on the property, the following applies:
(i) Permanently installed miscellaneous freestanding signs may be located only within three (3)
feet of driveways or curb cuts that provide access into or from the property. There shall be no more than two (2) such signs per driveway or curb cut and each such sign shall not exceed six (6) square feet in area nor more than three (3) feet in height.
(ii) Miscellaneous freestanding signs located farther from the road or street than the minimum building setback from that road or street right-ofway line on the property, shall be allowed provided that such
signs are no more than six (6) square feet in area nor more than six (6) feet in height.
(iii) Directory signs for multi-family lots to include UR-VL zoned lots are permitted provided they
do not exceed four (4) square feet each nor six (6) feet in height.
(iv) Display boards located next to drive-thru lanes. Such signs are permitted provided they do not exceed eight feet in height or 32 square feet in area.
(v) Miscellaneous Freestanding Signs will be permitted as part of the overall site design review process for new and expanded development.
History
(Ord. No. 2025-03, 6-3-2025)
Read this code where it is posted (Municode) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.