Skip to content
Georgia Commons
Menu

Troup County · Zoning Ordinance

Appendix B - LAND USE AND ZONING / Article V - CIVIC DESIGN

Sec. 5.6. Outdoor lighting.

About this text

  • As published by Municode, current through 2026-06-16
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

(1) Purpose. The regulations of this division are intended to:

(a) Permit reasonable uses of outdoor lighting for nighttime safety, utility, security, productivity, enjoyment, and commerce;

(b) Curtail and reverse the degradation of the nighttime visual environment and

the night sky;

(c) Preserve the dark night sky for astronomy;

(d) Minimize glare, obtrusive light, and artificial sky glow by limiting outdoor

lighting that is misdirected, excessive, or unnecessary;

(e) Conserve energy and resources to the greatest extent possible; and

(f) Help protect the natural environment from the damaging effects of night lighting from human-made sources.

(2) Conformance with applicable regulations.

All outdoor lighting devices must comply with the provisions of this section, the building code, and the electrical code, required permits and inspections, as applicable.

(3) General regulations.

(a) Outdoor lighting fixtures must be full cutoff and placed so as to allow no light above the horizontal as measured at the

luminaire, except as herein noted in this section (as in the case of period fixtures, cutoff fixtures may be used).

(b) Outdoor lighting fixtures must be located, aimed, or shielded to minimize glare and stray light trespassing across lot lines and into the public right-of-way.

(c) Flood or spot lamps must be positioned no higher than 45 degrees above straight down (halfway between the vertical and

the horizontal) when the source is visible from any off-site residential property or public roadway.

At Property Lines Including Rights-of-Way Maximum Foot-candles At property line abutting a residential or an agricultural or agritourism, and rural tourism use

0.5 At the property line abutting an office or institutional use 1.0 At the property line abutting all other uses 1.5 Off-Street

Parking Lots Minimum Foot-candles Average Foot-candles Maximum Foot-candles Agricultural or agritourism and Rural tourism uses None None 4.0 Residential uses 0.5 2.0—3.0 4.0 Office-professional uses 1.0 3.0—4.0 6.0 Industrial uses 1.0 4.0—5.0 8.0

All other uses 2.0 6.0—7.0 12.0

(d) All light fixtures that are required to be shielded shall be installed and maintained in such a manner that the shielding is

effective as described herein for fully shielded fixtures.

(e) Lighting on sites consisting of multiple uses must conform to the standards of

the respective uses.

(4) Parking areas. All lighting fixtures servicing parking lots must be directed downward and not towards buildings or other areas. Flood lights associated with buildings shall not be included in this requirement.

(5) Specific lighting regulations in the UR-VL districts:

(a) The following are expressly prohibited:

(i) Aerial lasers;

(ii) Searchlight-style lights;

(iii) Light sources that exceed 200,000 lumens or intensity in any direction of 2,000,000 candelas or more;

(iv) Mercury vapor lamps;

(v) Low-sodium vapor lamps;

(vi) Visually exposed neon lighting; and (vii) LED light strips.

(b) The following luminaries and lighting systems are expressly exempt from the

regulations of this division:

(i) Underwater lighting used for the illumination of swimming pools and fountains;

(ii) Temporary holiday lighting;

(iii) Lighting required and regulated by the Federal Aviation Administration, or other authorized federal, state, or local government agency;

(iv) Emergency lighting used by police, fire, or medical personnel, or at their direction;

(v) All outdoor light fixtures producing light directly from the combustion

of fossil fuels, such as kerosene and gasoline;

(vi) Security lighting controlled and activated by a motion sensor device for a duration of 10 minutes or less;

and

(6) Within the commercial and industrial corridor area.

i. Parking lot light fixtures shall have a maximum height of 35 feet.

ii. Security lighting is not required but may be used if deemed necessary by the owner or the design professional. Full cut-off luminaries shall be used.

iii. Exposed neon is prohibited.

History

The history line the source prints at the end of the section.

(Ord. No. 2025-03, 6-3-2025)

Read this code where it is posted (Municode) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.

Version local-code:troup-county/zoning/5.6@2026-06-16-75befaacd7

The assistant can say what this section says in this edition, quoting it and linking to it. It will not apply the law to your situation, and nothing here is legal advice.