Turin · Zoning Ordinance
Article 14 - CONSERVATION SUBDIVISION DISTRICT
14.3. Area and Bulk Requirements.
About this text
- As posted on the city's website, retrieved 2026-11-11
A. Density of Development. The maximum number of dwelling units allowed shall be the gross total acreage multiplied by 0.9.
B. Minimum Floor Area of Principal Structures. The minimum floor area for singlefamily detached structures within this district shall be 2,000 square feet heated space.
C. Minimum Restricted Greenspace. Designated restricted greenspace shall comprise no less that forty (40%) percent of the gross tract acreage and shall comply with all standards and criteria for greenspace contained in this Article.
D. Minimum Lot and Yard Areas. No minimum lot area is prescribed, rather, the following lot and yard area regulations shall apply to any principal residential structure or any other building:
1. Siting of principal dwellings located on laterally adjacent lots shall maintain a minimum separation of 20 feet, at any point. Siting of all buildings located on lots adjacent to the rear shall maintain a minimum separation of 50 feet measured perpendicularly from the rear wall of any residential structure to any point on any other building not accessory to such residential structure.
2. Minimum separation between accessory buildings and the principal structures to which they are accessory at any point shall not be less than that prescribed by applicable provisions of the Georgia statewide minimum construction codes;
minimum separation between accessory buildings and any other buildings shall comply with subsection 1.
3. No exterior windows, doors, or other openings shall be permitted in any portion of any principal or accessory structure located less than five (5) feet from any lot line.
4. Where any portion of any principal or accessory structure is located less than five
(5) feet from any lot line, a perpetual easement providing for maintenance of such structure, and measuring no less than five (5) feet in width from the affected walls shall be provided on the adjacent lot(s).
5. The building setback from the right-of-way of any street shall be a minimum of 25 feet.
6. All proposed dwellings shall be sited as to be setback a minimum of 50 feet from the perimeter boundary of the tract. Existing dwellings and dwellings resulting from the conversion of existing structures shall be exempt from this standard.
7. While conformance to these area and bulk regulations is not dependent upon any specific minimum lot area or dimensions, applicants shall be required to demonstrate to the satisfaction of the Council that any lots established under the provisions of this section are of appropriate size and shape relative to the following factors:
a. Establishment of suitable private yard areas for all residences; and
b. Management of any adjacent greenspace areas.
8. In submission of subdivision and/or land development plans, applicant shall indicate the maximum feasible building envelope for each lot created in compliance with these area and bulk requirements. The setbacks and separation distances between building envelopes on adjacent lots must meet the provisions of subsections 1 – 4, above. Such plans shall indicate where the provisions of subsections 3 and 4 apply.
E. Maximum Tract Coverage – Fifteen (15%) percent of gross tract area. Applicant shall calculate total permitted structure coverage in square feet and shall indicate on the Conceptual Plan the maximum coverage in square feet that will be assigned to each lot or parcel that will result from the proposed development.
Read this code where it is posted (city website) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.