Turin · Zoning Ordinance
Article 6 - GENERAL PROVISIONS
6.10. Buffer Zones.
About this text
- As posted on the city's website, retrieved 2026-11-11
A. Buffer Zones Required. Buffer zones shall be established and maintained in the following situations:
1. Where nonresidential districts are contiguous with residential districts.
2. Where single-family residential districts are contiguous with single-family residential districts of differing densities.
3. Where multi-family residential districts are contiguous with single-family residential districts.
4. Where preexisting nonresidential development is contiguous with proposed residential developments, and where no buffer in compliance with this Article is established on the nonresidential development where contiguous with the proposed residential district.
B. Minimum Buffer Zone Requirements. Buffer zones shall be required as indicated in the following table.
TABLE 6.10: MINIMUM BUFFER ZONE REQUIREMENTS
RD R40 RC R-1 GC GI
RD X 30’ 30’ 30’ 50’ 50’
R40 30’ X 30’ 30’ 50’ 50’
RC 30’ 30’ X 30’ 50’ 50’
R-1 30’ 30’ 30’ X 50’ 50’
GC 50’ 50’ 50’ 50’ X 50’
GI 50’ 50’ 50’ 50’ 50’ X
C. Buffer Zone Requirements. All buffer areas and screening shall be established in accordance with the following requirements:
1. Buffers shall be established and maintained along required property lot lines in accordance with the specifications that may be established by the Town Council.
2. Buffers shall meet the minimum width requirements for dissimilar districts as shown in the Table 6.10: "Minimum Buffer Zone Requirements".
3. The screening provided by the buffer zone shall be established within any buffer along the entire length of the side and rear lot lines. However, this screening requirement may be adjusted in order to observe the sight distance required in the Subdivision and Land Development Regulations or as a condition of zoning, special use, or variance approval or as approved by the Town Council.
4. Buffer zones shall be left in their natural state unless otherwise approved by the Town Council and not temporarily or permanently disturbed by grading, property improvements, or construction activities.
5. Buffer zones shall be used only for a buffer and shall not be used for paving, parking, or stormwater management areas.
6. Where required to achieve effective visual screening, the Town Council may require that existing native vegetation be supplemented with additional planting and/or with a wall, fence or berm.
7. Kudzu or other invasive species shall not be permitted in buffer zones and plantings shall consist of two or more evergreen species.
D. Buffer Requirements When Adjoining Preexisting Developments. When a proposed development adjoins a preexisting development(s) where a buffer would normally be required on the preexisting development, the developer of the proposed development shall be required to establish a buffer zone between the proposed project and the preexisting use.
This buffer zone shall meet all of the other requirements of Table 6.10 in order to establish said zone.
E. Buffer Requirements When Adjoining Another Municipal/Jurisdiction Boundary.
Where a proposed development, or expansion of an existing development, adjoins a parcel or parcels that are located outside of the Town of Turin, the proposed development shall provide a buffer zone in accordance with Table 6.10. The existing use and/or zoning classification of the parcels shall be examined and compared to an equivalent zoning district in the Table 6.10 to determine the appropriate width of the buffer zone.
Read this code where it is posted (city website) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.