A. Building Setback. Setback requirements in the Overlay shall be in accordance with the applicable underlying district unless a variance is obtained per section 15.8.
B. Utilities. All new utility lines shall be located underground. All mechanical, HVAC and like systems shall be screened on all sides by an opaque wall. Such screening shall be identical to the exterior finish materials of the principal building.
C. Landscaping: All developments shall to the extent practical provide entryway berming for the purpose of shielding parking areas, loading docks, dumpsters, and similar areas from view by employing the following methods, in order of preference:
1. Preservation of natural land forms, trees and other landscape elements
2. Landscaped berms with asymmetrical groupings of plant materials, including trees and shrubs which are long lived, and indigenous to Turin and this part of Georgia and 50 percent of which shall be evergreen species
3. Landscaped berms with linear, open form fences Buildings shall incorporate live plant materials as foundation plantings.
Any site furnishings such as railings, benches, trash receptacles and bicycle racks shall complement the building design and style.
A landscape buffer having a minimum horizontal dimension of 20 feet shall be provided along all property lines abutting Highway 16 and Highway 54. A landscape buffer having a minimum horizontal dimension of 15 feet shall be provided along all abutting residential property lines.
A minimum of 8 percent of the parking lot shall be landscaped. Landscaped areas shall be protected by raised curbs or fixed wheel stops and shall have a minimum area of 120 square feet and minimum dimension of 6 feet. No parking space shall be located more than 100 feet from a canopy tree.
One canopy tree shall be planted for every 250 square feet of landscaped area. Shrubs shall be planted at a ratio of three for every one tree.
A minimum of 20 percent of all existing trees having a diameter of 12 inches or greater shall be retained. This requirement shall be in addition to the standards of any required landscape area; however, such retention may be achieved through tree preservation within such areas.
D. Detention Facilities. Detention ponds or retention areas shall be designed to blend with adjacent landscaped areas to the greatest possible extent. Such stormwater facilities may be located within a buffer; however, when located adjacent to the perimeter of the building site, fenced ponds shall not be located in a front yard or within 50 feet of a property boundary.
E. Signs: All signage shall be in accordance with Article 10 of this ordinance.
F. Loading Areas: Loading docks and loading areas shall be located or screened so as to be concealed from view from neighboring streets and properties. No loading dock shall be located between the primary or secondary façade of any building and a public street. All loading docks shall be screened from view of any street or residentially zoned lot by a continuous planting of evergreen shrubs. Shrubs shall be moderately growing, be a minimum height of six (6) feet at time of planting, and reach a height of eight (8) feet within two years of planting. Commercial properties that adjoin a residential zoning lot to the rear shall enclose loading areas using a masonry wall constructed of materials and exterior finishes identical to the side elevations and having a minimum height of 6 feet and a maximum height of 10 feet.
G. Outdoor Storage: No unenclosed, outside storage shall be permitted. Such enclosure as will permit unroofed, outside storage shall be comprised of walls having a minimum height of 6 feet, but in no case less than the height of equipment, materials, merchandise or other goods to be stored or exceeding 10 feet in height. These walls shall be identical in exterior finish materials to the walls of the primary or secondary façade of the principal structure. Fencing, with or without typical fence screening materials, shall not be considered as a screening wall. Chain link fencing is prohibited. Outdoor display of merchandise shall be permitted provided such display is located adjacent to the principal structure and conforms to the setbacks for the zoning district.
H. Pedestrian Improvements. All developments shall provide sidewalks having a minimum width of 6 feet along all frontages of the lot that abut a public street. Continuous on site sidewalks having a minimum width of 4 feet shall be provided from the public sidewalk to the principal customer entrance of all buildings on the site. Such sidewalks shall provide weather protection features such as awnings or arcades along the building façade within 30 feet of all customer entrances. Sidewalks shall connect focal points of pedestrian activity such as, but not limited to, street crossings, building and store entrances.
Sidewalks having a minimum width of 6 feet shall be provided along the full length of the building façade featuring a customer entrance, and along any façade abutting public parking areas. All buildings shall provide direct pedestrian access from on-site parking areas as well as the public sidewalk. All on site sidewalks shall be distinguished from vehicular surfaces through the use of durable, low maintenance materials such as pavers, bricks, or scored concrete to enhance pedestrian safety.
I. Lighting Design. Streetlights shall be provided along all public right-of-ways utilizing decorative light poles and fixtures consistent with the design adopted by the Town for the Overlay. The light source shall be high-pressure sodium. Streetlights shall be staggered, 150 feet on-center, along both sides of the roadway. Lighting in parking areas shall provide area lighting sufficient to achieve a minimum illumination of 2.4 foot-candles of light as measured at grade level and recommended in the IESNA Lighting Handbook. All building entrances, walks and vehicular access shall be lit. The following lighting guidelines shall apply:
1. Walk and Access Lighting: 120-Volt Halogen 20 to 50 Watts.
2. Architectural and Landscape Lighting: 120-Volt Halogen 50 to 100 Watts.
J. Dumpsters: Dumpsters shall be screened from view on all four sides. Screening shall consist of three solid walls of brick, stone or stucco construction, a minimum of six feet in height, and the fourth wall shall be comprised of opaque metal or wooden gates. The gate opening shall have a minimum width of 12 feet. All dumpster shall be equipped with lids.
The pad of the gated dumpster enclosure shall be concrete pad and all dumpster approaches shall also be concrete and have a minimum length of 10 feet. Dumpster shall be located a minimum of 50 feet from any residential zoning district or use, and the Highway 16 or Highway 54 right-of-way, but may otherwise be located within any required building setback.