(A) Schedule of residential district dimensional requirements. Zoning District Minimum Lot Area (square feet) Minimum Yard Setback Distance (feet) Maximum Structure Height (feet) — SingleFamily Two-Family Multi Family Front Rear Side — R-1 12,000 Not permitted Not permitted 20 20 10 35 R-1-B 6,600 Not permitted Not permitted 20 10 10 35 R-2 4,500 6,750 Not permitted 20 10 10 35 RT 7,000 8,000 8,000 buildable to 80 percent of the property exclusive of the setbacks 20 20 10 35 (1) In any residential district (R-I, R-I-B, R-2 and RT) where the average front setback distance for existing buildings on all lots located wholly or partly within 200 feet to each side of any lot, and within the same zoning district and fronting on the same side of the same street and on the same block as such lot, is less than the minimum setback required in such zoning district, the front setback on such lot may be less than the required setback but not less than the existing average setback distance for all lots within 200 feet to each side, provided that in no case shall the front setback on new construction be less than ten feet. When lots within 200 feet on each side are vacant such vacant lots shall be considered as having the minimum required setback for the purpose of computing an average setback distance. When existing structures on lots within 200 feet on each side exceed minimum front setback required in such zoning district, the required setback shall be used for the purpose of computing an average setback distance. See illustration and table for visual clarification. (2) A second set of stairs from an existing elevated home or existing home to be elevated in the future may encroach into the setback upon approval of the zoning administrator. The stairs shall encroach as little as possible into the setback. (3) An encroachment to permit one elevator is permissible on an existing elevated home to accommodate an elevator into a side or rear setback but only to the extent necessary to accommodate the elevator and the appropriate shaft and the encroachment shall be no larger than six feet by six feet within the setback and no component or part shall protrude more than six feet into the setback upon approval of the building official. (B) Schedule of other than residential districts (commercial, maritime and transitional business-residential) dimensional requirements* . **Zone Minimum Lot Area (square feet) Front Yard Rear (feet) Side (feet) Maximum Structure Height (feet) C-1(A)*** (Not applicable to allowed uses) 0 None required except 15 feet if bordering residential use. None required except 15 feet if bordering residential use. 35 C-1(B) (Not applicable to allowed uses) 8 6 5 35 C-1(C) 4,500 SingleFamily 6,750 Two-Family 1,125 per unit MultiFamily 20 10 10 35 C-2 (Not applicable to commercial uses) 10 6 6 35 **Zone Minimum Lot Area (square feet) Front Yard Rear (feet) Side (feet) Maximum Structure Height (feet) M-D (Not applicable to allowed uses) 20 10 10 35 TBR 4,500 SingleFamily 6,750 Two-Family 20 10 10 35 *When abutting public streets, any principal structure shall be located no nearer than five feet to that lot line. **Where a commercial establishment abuts a residential zoning, a suitable screen will be required. See section 3-160. This screen shall be either natural (planting) or manmade and shall be maintained in good order and approved by the zoning administrator. Minimum height is six feet. ***C-1(A) Retail uses and food/beverage service uses. C-1(B) Hotel and motel uses, with 80 percent maximum lot coverage. C-1(C) Residential uses, including single-family, two-family, and multi-family (triplexes, quadraplexes, townhomes, apartments, tourist homes, condominiums, timeshares, and similar uses), bed and breakfast uses, and public structures. (C) Structures above 35 feet. If a variance is granted by the mayor and council for a building with a height in excess of 35 feet, in no event shall a building permit be granted without the following restrictions: (1) Structures greater than 35 feet in height shall be fully equipped with fire safe guards consisting of sprinkler systems, smoke detectors and any other fire protection measures deemed necessary at the time by the mayor and council. (2) Before a permit can be granted on said request, an affidavit of the builder and owner must be executed agreeing to same to be completed within an agreed upon reasonable time. (D) Calculating maximum height for development on existing structures or slabs. In any situation, including specifically but not limited to, the batteries that were formerly part of Fort Screven, where new construction or remodeling of existing improvements is proposed, the elevation for purposes of calculating the finished height of the proposed structure shall be determined by the following rules: (a) The finished height of any new construction or remodeling shall not exceed 35 feet from the lower of the existing elevation as determined from either of the following: (1) The elevation of the top of the lowest floor's slab of the existing improvement or structure, or (2) The elevation of the crown of an existing improved street, public or private, that abuts or is nearest to the property on which the proposed structure is planned. This section is applicable in circumstances where the existing structure, improvement, or slab is to be continued in use or in place, incorporated into the proposed improvement. If an improvement, slab and/or foundation is to be removed entirely, the elevation for new construction will be measured from the lower of the average adjacent grade of the lot or the elevation of the crown of an existing improved street, public or private, that abuts or is nearest to the property on which the proposed structure is planned. As used in this article, the phrase "is nearest to" is to be determined by a measurement in any direction and without regard to property lines, easements, etc. but rather is to be determined "as the crow flies," beginning with the closest point on the property to be developed to the nearest improved public or private street. As used in this article, the words "grade," "foundation" and "slab" shall be defined as demonstrated and depicted on the attached Exhibit "A" and this article is to be applied and interpreted consistently therewith.