Appendix A - ZONING / Article IX - SPECIAL PROVISIONS

9.1.7.3. No more than one residence shall be permitted on each lot.

About this text

  • As published by Municode, retrieved 2026-11-11
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

9.1.7.4 All manufactured homes located within the subdivision shall be blocked and tied down according to manufacturer's specifications and shall have a curtain wall of brick or masonry construction.

9.1.7.5 All manufactured homes located within the subdivision shall comply with the requirements numbered 1 [9.1.3.1] and 2 [9.1.3.2] as specified in section 9.1.3 of this ordinance.

9.1.7.6 All residences, other than on-site built houses, located within the subdivision shall bear the H.U.D. seal or the Georgia D.C.A. seal, and the overall appearance shall be such as will not detract from the overall appearance of the subdivision.

9.1.7.7 Tie downs: All manufactured homes placed in Union Point, Georgia at or after the adoption of this ordinance shall have tie downs with provisions for distributing the load of these tie downs and provisions for the attachment to ground anchors so as to resist wind overturning and sliding as imposed by the respective design loads of this section.

(a) Each tie down shall be designed to resist an allowable working load equal to or exceeding 3,150 pounds and shall be capable of withstanding a 50 percent overload without failure.

(b) Unless the tie down system is designed by a registered professional engineer or architect, tie downs shall be placed as follows: not more than 24 feet on center beginning from the front wall (first stud and/or first cross member).

Not more than six feet open-end spacing shall be provided at the rear wall of the mobile or manufactured home unless additional tie downs are installed.

(c) Provisions for diagonal ties between ground anchors and the manufactured home shall be made in conjunction with each vertical tie down.

(d) Tie downs exposed to weathering shall be resistant to weathering deterioration at least equivalent to that provided by a coating of zinc on steel of not less than 0.30 ounces per square foot of surface coated. Type 1, Class B, Grade 1, steel strapping 11

/4 inches wide and 0.035 inches thick, conforming with federal specification QQ-S-781-F, is judged to conform with this section.

9.1.7.8 Ground anchors shall be installed at each manufactured home stand or pad when a mobile or manufactured home is located thereon, pursuant to the following requirements:

(a) Each ground anchor shall be capable of resisting an allowable working load equal to or exceeding 3,150 pounds applied in the direction of the tie down.

In addition, each ground anchor shall be capable of withstanding a 50 percent overload without failure.

(b) Ground anchors shall be resistant to weathering deterioration at least equivalent to that provided by a coating of zinc on steel strapping of not less than 0.30 ounces per square foot of surface coated.

Read this code where it is posted (Municode) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.

Version local-code:union-point/zoning/9.1.7.3@2026-11-11-bdaca43760

The assistant can say what this section says in this edition, quoting it and linking to it. It will not apply the law to your situation, and nothing here is legal advice.

Union Point Zoning Ordinance, 9.1.7.3. No more than one residence shall be permitted on each lot | Georgia Commons