--- title: Vienna Zoning Ordinance, Sec. 82-101. Photovoltaic solar energy production facilities; restrictions and conditions collection: local-codes id: local-code:vienna/zoning/82-101 cite_as: Vienna, Ga., Zoning Ordinance ยง 82-101 canonical_url: https://georgiacommons.org/code/local/vienna/zoning/82-101 md_url: https://georgiacommons.org/code/local/vienna/zoning/82-101.md text_url: https://georgiacommons.org/code/local/vienna/zoning/82-101/text source_url: https://library.municode.com/ga/vienna/codes/code_of_ordinances date: 2026-11-11 status: active jurisdiction: city:vienna jurisdiction_name: Vienna place_fips: "1379444" corpus_version: local-codes-vienna-3d77f3672c34 publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/code/local/vienna/zoning/~part-ii/~chapter-82/~article-iii.md previous: https://georgiacommons.org/code/local/vienna/zoning/82-100.md next: https://georgiacommons.org/code/local/vienna/zoning/82-102.md index: https://georgiacommons.org/code/local/vienna.md branch: zoning edition: As published by Municode, retrieved 2026-11-11 edition_date_kind: retrieved source_publisher: Municode version_id: local-code:vienna/zoning/82-101@2026-11-11-00f28da60b --- # Vienna Zoning Ordinance, Sec. 82-101. Photovoltaic solar energy production facilities; restrictions and conditions > As published by Municode, retrieved 2026-11-11 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Part II - CODE / Chapter 82 - ZONING TABLE OF CONTENTS / Article III - APPLICATION OF REGULATIONS Photovoltaic solar energy production facilities shall be allowed in all districts as a special exception use and shall be subject to the following restrictions and conditions: (1) Area of use may not exceed 100 acres on-site with no aggregation of solar collection panels on adjacent properties which exceeds 100 acres; and (2) Photovoltaic solar energy production facilities may consist only of solar collection systems in residential districts and may be used for on-site purposes only; and (3) Solar energy production facilities shall adhere to the setback and height requirements of the district in which they are located. Ground-mounted systems shall be fenced with "Danger - High Voltage" warning type signs attached to said fencing at intervals of not more than 100 feet; and (4) Solar energy production facilities shall be visually screened from abutting residential properties through any one or combination of the following: (1) plantings; (2) existing vegetation; or (3) fencing not to exceed eight feet in height; and (5) The manufacturers' or installers' identification, the facility owner's name and contact information, and the appropriate warning signage shall be posted on or near the panels in a clearly visible manner and on the required fencing; and (6) All electrical interconnection and distribution lines within the project boundary, except for power lines that leave the project or are within the substation shall be underground unless otherwise determined by the Mayor and City Council of the City of Vienna because of severe environmental constraints; and (7) Lighting of the solar energy production facility and accessory structures shall be limited to the minimum lumens required for access or necessary repair and replacement and said lighting shall not be directed at residential structures on abutting property existing as of the date of construction of said facility; and (8) Solar panels shall be designed and installed to prohibit sun reflection in such a manner to impede vehicular traffic and any habitable portion of an adjacent or abutting structure. Lighting of the solar energy production facility and accessory structures shall be limited to the minimum lumens required for access or necessary repair and replacement and said lighting shall not be directed in such fashion as to impede vehicular traffic; and (9) Professional engineered drawings that clearly illustrate the design of the solar energy production facility shall be submitted as part of the special exception use application package. Manufacturers' drawings for solar collection systems in residential systems may be submitted in lieu of professional engineered drawings. The Planning and Zoning Commission of the City of Vienna may apply aesthetic consideration when making recommendation to the Mayor and City Council of the City of Vienna for approval or disapproval; and (10) Any solar energy production facility that has not been in use for its original purpose for a period of 180 days as determined by records of the production facility owner, property owner, or City of Vienna shall be deemed to be abandoned. The solar energy production facility owner and/or the property owner shall have 90 days to remove the abandoned solar energy system and any appurtenant structures or to reactivate the solar energy system; and (11) The Planning and Zoning Commission of the City of Vienna may, in its discretion, recommend to the Mayor and City Council of the City of Vienna to waive any of the above-listed conditions or may recommend that additional and appropriate conditions and safeguards in conformity with this Ordinance be prescribed in order to mitigate the impact of the use to surrounding uses and to otherwise protect public health, safety and general welfare. Violation of each such condition and safeguard, when made a part of the terms under which the conditional use is granted, shall be deemed a violation of this section. Each day such violation occurs shall be considered a separate and distinct violation of this section. (12) Ground-mounted accessory solar panels. a. Ground-mounted accessory solar panels shall only be permitted in the rear and side yard in the commercial zoned districts, and in the rear yard only of residential zoned districts. b. Ground-mounted solar panels located on the ground or attached to a framework located on the ground shall not exceed eight feet in height above the ground. c. Ground-mounted solar panels shall meet the setback as required for in the districts in which they are located. d. The total coverage of a lot with ground-mounted solar panels cannot exceed 20 percent lot coverage. e. Ground-mounted systems shall be screened from any adjacent property that is residentially zoned or used for residential purposes. The screen shall consist of plant materials which provide a visual screen. In lieu of a planting screen, a decorative fence meeting requirements of the zoning ordinance may be used. f. The manufacturers' or installers' identification and appropriate warning signage shall be posted on or near the panels in a clearly visible manner. (13) Roof-mounted solar panels. a. Roof-mounted solar panels shall be located only on rear or side-facing roofs as viewed from any adjacent street. b. A roof-mounted system may be mounted on a principal building or accessory building. c. A roof-mounted system, whether mounted on the principal building or accessory building, shall be subject to the maximum height regulations specified for building within the underlying zoning district. d. In no instance shall any part of the roof-mounted system extend beyond the edge of the roof. e. The panels shall not be located within three feet of any peak, eave or valley of the roof to maintain pathways of accessibility. f. The manufacturers' or installers' identification and appropriate warning signage shall be posted on or near the panels in a clearly visible manner. (14) Historic district overlay. Solar energy production facilities are allowed in the historic district overlay; are subject to the above regulations and the Vienna Historic District Guidelines. A certificate of appropriateness from the Vienna Historic Preservation Commission is required prior to permitting. ## History (Ord. of 9-23-13(3); Ord. of 8-25-14)