--- title: Waleska Zoning Ordinance, Sec. 28-607. Dimensional standards and density determination collection: local-codes id: local-code:waleska/zoning/28-607 cite_as: Waleska, Ga., Zoning Ordinance § 28-607 canonical_url: https://georgiacommons.org/code/local/waleska/zoning/28-607 md_url: https://georgiacommons.org/code/local/waleska/zoning/28-607.md text_url: https://georgiacommons.org/code/local/waleska/zoning/28-607/text source_url: https://library.municode.com/ga/waleska/codes/code_of_ordinances date: 2026-11-11 status: active jurisdiction: city:waleska jurisdiction_name: Waleska place_fips: "1379948" corpus_version: local-codes-waleska-acae3e5aee1b publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/code/local/waleska/zoning/~part-ii/~chapter-28/~article-xx.md previous: https://georgiacommons.org/code/local/waleska/zoning/28-606.md next: https://georgiacommons.org/code/local/waleska/zoning/28-608.md index: https://georgiacommons.org/code/local/waleska.md branch: zoning edition: As published by Municode, retrieved 2026-11-11 edition_date_kind: retrieved source_publisher: Municode version_id: local-code:waleska/zoning/28-607@2026-11-11-32e4530590 --- # Waleska Zoning Ordinance, Sec. 28-607. Dimensional standards and density determination > As published by Municode, retrieved 2026-11-11 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Part II - CODE OF ORDINANCES / Chapter 28 - ZONING / Article XX - CONSERVATION SUBDIVISION (a) Density neutral. The number of lots created shall be density neutral. The term "density neutral" is defined as maintaining the number of lots so as not to exceed the number that can be created with the conventional minimum area and width requirements of the zoning district designation of the subject property (Table 28-607(a)). Table 28-607(a). Conservation Subdivision Density and Lot Size Requirements Existing Zoning District Maximum Density DUA (units/ acre) Minimum Lot Size (sq. ft.) R-80 0.5445 40,000 R-40 1.089 20,000 R-30 1.452 15,000 (b) Housing density determination. The maximum number of lots in a conservation subdivision shall be determined by either of the following two methods, at the discretion of the applicant: (1) Calculation method. The maximum number of lots is determined by multiplying the net tract area by the maximum density units/acre factor (see Table 28-607(a)) specified in the underlying zoning. The net tract area is calculated as outlined below: a. Step 1. Calculation of the constrained lands: 1. Total area of land in subsection (b)(1)a(i)—(iv) of this section multiplied by 0.50: (i) Slopes over 35 percent of at least 5,000 square feet contiguous area. (ii) The 100-year floodplain. (iii) Wetlands that meet the definition of the Army Corps of Engineers pursuant to the Clean Water Act. (iv) Area of land in stream buffers as required by federal, state, or local regulations. 2. Total area of land in subsection (b)(1)a(i)—(ii) of this section: (i) Area of land designated for construction of roads and associated ROW. (ii) Area of all impervious surfaces associated with amenities, including but not limited to parking areas, tennis courts, swimming pools, clubhouses, and other. Constrained lands = (Total area of land in subsection (b)(1)a(i)—(iv) of this section × 0.5) + total area of land in subsection (b)(1)a(i)—(ii) of this section. b. Step 2. Net tract area. Once the area of constrained lands has been calculated, the net tract area is calculated by subtracting the area of constrained lands from the gross tract acreage of the property to be development as a conservation subdivision. (2) Yield plan method. a. The maximum number of lots is based on a conventional subdivision design plan, prepared by the applicant, in which the tract of land is subdivided in a manner intended to yield the highest number of lots possible. The plan does not have to meet formal requirements for a site design plan, but the design must be capable of being constructed given site features and all applicable regulations. Such yield plan shall be reviewed by the appropriate county or city staff to verify such plan meets the minimum criteria for development as proposed. b. Where the number of lots allowed under the yield plan method results in more lots than the number of lots under the calculation method, the lot size may be reduced by 50 percent of the permissible lot size in Table 28-607(a) to accommodate the difference in the number of lots between the two methods. Where on site sewage management systems are to be used, the size of the lots shall be no less than that required by the health department. (c) Area and yard requirements; locations and structures. (1) Placement. The placement of all principal buildings shall provide for safe, quiet, and harmonious grouping as well as adequate privacy by providing adequate front, side, and rear yards (Table 28-607(c)). (2) Location. Structures shall be placed so as to fulfill the objectives of sections 28-604 and 28-605 to minimize any adverse effect on the environment and to take advantage of ecological conditions (Table 28-607(c)). Table 28-607(c). Conservation Subdivision Setback Requirements Density (DUA) Allowable Minimum Lot Size Setbacks Front Side Rear 0.5 40,000 35 feet 15 feet 30 feet 0.5445 40,000 35 feet 15 feet 30 feet 0.726 30,000 35 feet 15 feet 30 feet 1.089 29,000 25 feet 10 feet 25 feet 1.452 15,000 20 feet 10 feet 25 feet 2.178 10,000 20 feet 10 feet 25 feet 2.904 7,500 20 feet 10 feet 15 feet