(a) The following luminaire source types and wattages shall be subject to this article: (1) All metal halide, fluorescent, and mercury vapor. (2) High-pressure sodium: exceeding 35 watts. (3) Low-pressure sodium: exceeding 18 watts. (4) Incandescent and quartz-halogen: exceeding 100 watts. (b) Filtering of source types. Mercury vapor, fluorescent, and metal halide lamps shall be installed in luminaires enclosed by acrylic, translucent material, or glass which filters out ultraviolet light; quartz glass does not qualify.