Walnut Grove · Zoning Ordinance

Appendix A - ZONING / Article IX - USE PROVISIONS

Sec. 911. Overlay districts.

About this text

  • As published by Municode, current through 2025-09-23
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

A. Purpose. Overlay zoning districts are supplemental to the base zoning district classifications established in this article. All development and building permits for a lot located in any overlay zoning district shall meet all of the requirements of the base zoning district in which it is located and, in addition, shall meet all of the requirements of the overlay district applicable to said lot. Where there is a conflict between the standards and requirements of the overlay district and the base district, the standards and requirements of the overlay district shall govern.

B. Location. The boundaries of certain overlay zoning districts shall be determined by physiological and hydrological boundaries as described within the district descriptions and standards, such as the Watershed Protection Overlay District. The other districts shall be "floating zones" that are determined on a case-by-case basis upon approval of the application by the city council.

C. Cornish Creek Watershed Protection Overlay District (W-P1).

1. Purpose and intent. The intent of this overlay district is to protect the designated watershed areas from the possible adverse effects of residential and nonresidential development such as the leaching of septic systems, increased stormwater runoff, sedimentation and other sources of water pollution, in order to insure water quality. All property within this district shall simultaneously carry the zoning district designation of the underlying zoning district as well as the W-P1 designation.

2. Location of the district. The W-P1 Watershed Protection Overlay District is comprised of all land areas within the Cornish Creek Watershed Basin within the city limits which has been officially designated for use as public water supplies. The W-P1 Watershed Protection District is shown on the official zoning maps of Walnut Grove, Georgia. In all cases, the watershed is defined by the ridgelines that separate the flow of stormwater between the Cornish Creek Watershed Basin and all other watersheds. The actual boundary of W-P1 Watershed Protection Overlay District must therefore be determined on a property-by-property basis using the actual topography of each site.

3. Permitted and conditional uses.

a) In the W-P1 Watershed Protection Overlay District, the permitted uses, as well as the conditional uses, shall be those of the underlying zoning district provided for in this ordinance, except where the provisions of this overlay district differ or are more restrictive than the underlying zoning district.

b) The following uses are restricted in all zoning districts within the W-P1 district:

1) Sanitary landfills are prohibited.

2) Hazardous waste treatment or disposal facilities are prohibited (except septic tanks).

3) Facilities which handle hazardous materials, of the types and amounts regulated by the Georgia department of natural resources, are prohibited.

4) Mining and quarrying activities are prohibited.

4. Required greenways and setbacks. The following greenways and setbacks are hereby established along each perennial stream (i.e., a stream that flows throughout the year) and water impoundment (i.e., a pond or lake) in the W-P1 district:

a) Stream greenway. The area extending a distance of 100 feet from the banks of all perennial streams. This area shall remain natural and undisturbed except as otherwise provided in this district, below.

b) Stream setback. The area extending a distance of 150 feet from the banks of all perennial streams.

c) Water impoundment greenway. The area extending a distance of 100 feet from the normal pool elevation of any water impoundment, except that greenway requirements shall not apply adjacent to the dam side of the impoundment. The greenway shall remain natural and undisturbed except as otherwise provided in this district, below.

d) Water impoundment setback. The area extending a distance of 150 feet from the normal pool elevation of any water impoundment.

5. Stormwater management.

a) With the exception of an individual single-family residential lot, all development sites and subdivisions shall provide stormwater detention in accordance with the requirements of article 6 of the comprehensive land development ordinance of Walnut Grove.

b) If a subdivision (residential or nonresidential) project is provided with an on-site stormwater detention facility, a property owner's association shall be established for its ownership and maintenance. The association bylaws shall be recorded concurrently with the recording of a final subdivision plat. The association bylaws shall include the following provisions:

1) Automatic (mandatory) membership of all purchasers of lots therein and their successors;

2) Conditions and timing of transferring control of the association from the developer to the lot owners shall be specified which shall not exceed four years from the date of recording of the final plat of the subdivision;

3) Responsibility for maintenance, insurance and taxes;

4) Sharing of the costs of maintenance among the lot owners with shares defined by the association bylaws;

5) Authority to place liens on the real property of members who fail to pay their dues or assessments; and

6) Prohibition on the dissolution of the association without the approval of the city council.

6. Limitation on variances. Variances from the provisions of the W-P1 Watershed Protection Overlay District are prohibited except as follows:

a) Lots of record. All lots or parcels of record as of the effective date of this amendment and all lots or parcels that are shown on a preliminary plat approved by the city prior to the effective date of this amendment, that are made unbuildable by the stream or water impoundment greenway or setback provisions of this district, may still be developed on a case-by-case basis. Requests for development of these lots shall be made to the city in accordance with the provisions of article XIII. If development is allowed, the minimum possible impervious surface and maximum setback and greenway width, given the configuration of the lot, shall be maintained.

b) Nonconforming lots, buildings and uses. Nonconforming lots, buildings and uses shall be governed by the provisions of article VIII, section 800, [related to] nonconforming building and uses.

D. DOD Downtown Overlay District.

1. Purpose and intent. The purpose of the DOD Downtown Overlay District is to establish architectural, landscaping, design, building, and use and site development regulations that encourage compatible land uses, ensure higher quality development and function in order to protect property values and provide safe and efficient pedestrian and automobile access. These architectural, landscaping, design, building, use and site development criteria can encourage quality development through the use of a variety of design and site techniques while continuing to provide for a wide range of economic development opportunities.

2. Boundaries. The downtown overlay district corresponds generally with properties fronting on Georgia 81 from the southern city limits through the crossroads to Park Street and along Georgia 138 from city limits to city limits. The overlay district also includes properties north of SR 138 and east of SR138 in an area proposed to be opened up for new development consistent with the goals of the comprehensive plan. The downtown overlay district shall include those properties as shown on the official zoning district map of Walnut Grove referenced and adopted in section 16.4 of this zoning ordinance.

3

Amendments to boundaries. The boundary of the Downtown Redevelopment Overlay District may be amended in accordance with articles I and XIV of this zoning ordinance.

4. Relationship to underlying zoning district provisions. The downtown overlay district is an overlay zone. The land use regulations applicable to the underlying zone remain in full force and effect except where superseded herein. Where there is a provision not expressed in the underlying zone, or where a provision hereof is in conflict with the underlying zone, the provision of the overlay district shall be controlling.

5. Permitted uses. Uses that are permitted in the underlying zoning district, whether by right of by conditional use permit, are allowed within the downtown overlay district unless prohibited by section 911.5.

6. Prohibited uses. These uses are expressly prohibited in the DOD [Downtown] Overlay District:

A. Gas stations and automotive repairs and body shops.

B. Automobile, motorcycle, and truck sales.

C. Outdoor storage of vehicles or merchandise.

D. Warehousing.

E. Any retail use with a gross floor area in excess of 50,000 square feet.

7. Nonconforming uses. All existing prohibited uses currently in the DOD area may continue to exist as a lawful nonconforming use in keeping with the provisions of section 800.

8. Development standards. The following development standards shall apply within the DOD.

A. For lots adjoining Walnut Grove Parkway:

1. Yards. The setback from the right-of-way (front yard), side yard and rear yards may be reduced to zero feet.

2. Maximum lot coverage may be increased to 75 percent.

3. Minimum lot width may be reduced to 25 feet.

4. Parking.

a. Development proposals shall provide on-street parking spaces along the entire property frontage, except for approved driveway openings or where parking spaces will interfere with turning movements at intersections.

b. On-street parking spaces provided by the developer adjacent to their project shall be counted towards the minimum number of spaces required. Off-street parking shall be provided at the side or rear of the property and sharing of parking spaces may be allowed as per the provisions of section 1104 of this ordinance.

c. Properties forming commercial blocks, where the building extends from side lot line to side lot line, may provide parking in the rear of the buildings, on the corner of such block or pooled parking at an adjacent public/private lot. The applicant shall show proposed pooled parking areas in their development plans before any such requests shall be approved.

5. Sidewalks. Sidewalks shall be provided on both sides of the street and shall also connect to the front door/porch of all principal buildings. The sidewalks shall be a minimum of six feet in width and constructed in accordance with section 408 of the Walnut Grove land development ordinance.

B. For lots adjoining other roadways within the DOD.

1. Minimum yard sizes shall meet the requirements of section 900.J.

2. For parcels, lots or building sites abutting SR 138 and SR 81, where on-street parking is not allowed, the required number of parking spaces shall be provided in the side or rear of the property, except for one double row of parking in the front of the building. The provisions of section 1104 may be applied where all required parking cannot be provided on the lot in question.

3. Sidewalks. Sidewalks shall be provided on both sides of the street and shall also connect to the front door/porch of all principal buildings. The sidewalks shall be a minimum of six feet in width and constructed in accordance with section 408 of the Walnut Grove land development ordinance.

9. Design guidelines. The downtown overlay district is an integral commercial center; it represents an important part of the city's heritage and its character creates an identity for Walnut Grove today. Compatible design helps to enhance the quality of life for all residents while strengthening the economic viability of the downtown. The downtown overlay district design guidelines seek to encourage visual harmony and historic integrity and encourage creative design solutions. The design guidelines do not dictate style, but rather suggest a variety of choices for achieving design compatibility within the downtown overlay district. The design guidelines can also help to protect the property values by encouraging improvements that maintain buildings as viable assets. The design guidelines apply only within the downtown overlay district and supplement the site and design criteria provisions of this section. They are triggered by change to the urban design features, architectural features and on- and off-site construction or improvements for new or redeveloped parcels as follows:

A. Architectural character.

1. The purpose of this section is to present an architectural vocabulary that will provide a general guideline for the development of commercial and public buildings within the downtown overlay district. In general, Walnut Grove requires turn-of-the-century (1880 to 1930) architectural styles, themes, massing and details.

2. Any literal transplant of architectural styles not indigenous or compatible to this area is not acceptable. Similarly, a structure monumental in scale or unduly formal or modern in character, and any corporate signature buildings or structures, are not acceptable within the City of Walnut Grove.

B. Proportion and scale.

1. Proportion. All development proposals shall indicate that the applicant has studied and reconciled the scale and proportions of buildings in the following situations:

a. Site.

b. Adjacent and neighboring sites.

c. Major streets from which the project will be accessed or viewed.

2. Horizontal emphasis. Building proportions with horizontal emphasis shall be minimized. Vertical proportions that exaggerate building height shall instead be utilized wherever feasible.

3. Varied facades. The spacing of elements in facades shall be varied rather than repetitive, with a high priority placed on the three dimensional interplay of light and shadow.

4. Scale.

a. Human scale. Building elements and facades, especially at the ground or pedestrian level, shall be intimate and close to human size, so as to achieve a sense of human scale and interest.

b. Overall scale. A mixture of scales shall be permitted in less pedestrian areas, with some elements scaled larger for appreciation from the street.

5. Building massing. All new development proposals shall incorporate means of reducing the apparent size and bulk of the building. The following methods for reducing the apparent size and mass of larger buildings shall be required:

a. Continuous wall surfaces. Large or continuous wall surfaces shall be prohibited. Large building surfaces shall be relieved with a change of wall plane that provides strong shadow and visual interest. Pilasters and/or false windows shall be incorporated into the design so that horizontal walls are broken up at least every 20 feet.

b. Building base. The building base shall be a shaded element that establishes a strong connection to the ground and site. The base is often a different material and/or color as in a water table or could be a larger element that incorporates individual awnings or coverings. Continuous arcades shall be prohibited.

c. Breaking up building mass. Every building shall reduce its perceived height and bulk by dividing the building mass into smaller scale components. Building wall offsets, including projections, recesses, and changes in floor level shall be used to add architectural interest and variety, and to relieve the visual effect of a simple long wall.

d. Variation in building silhouettes. Variation in the roofline of buildings is desirable. Offsets in pitched roofs and gables are encouraged. Parapets in building masses exceeding 50 continuous linear feet shall be varied in height and project and shall use decorative elements such as crown moldings, dental, brick soldier courses, etc.

C. Visual patterns and color.

1. Shade and shadow. Recesses and projections shall be utilized to divide horizontal surfaces of buildings into smaller scale elements to produce strong shade and shadow.

2. Projections. Projections shall be permitted for use to emphasize important architectural elements such as stairs, balconies, entrances, bays, etc.

3. Reduce unrelieved building mass. The use of individual awnings, partial loggias (not full arcades), wide roof overhangs, etc., shall be permitted to be used to produce interesting shadow effects and reduce unrelieved building mass.

4. Color. Building colors shall be carefully chosen so that each building compliments that of its neighbor. An entire block of buildings should blend together even though each building will possess its own identity.

a. Main building. The main building color shall be of historic earth tones. Loud, bright, or contemporary colors shall be prohibited.

b. Trim. Historically, building trim was of a natural stone or in the case of painted elements was painted in a decorative manner in a contrasting shade lighter or darker than the main building. The palate of trim colors shall be historic in nature such as navy, sage, maroon, slate gray, fawn, gold, etc.

D. Architectural details. Surface detail, ornament, windows and doors that enrich the architectural character shall be required.

1. Integration of details. Details shall be carefully considered to add interest and human scale. All visibly exposed sides of a building shall have an articulated base, course, and cornice.

2. Trim. The trim adds detail and character to the facade. Said trim shall include the eaves, pediments, friezes, lintels, sills, belt courses, balustrades, quoins. Windows shall have capitals, arches, jack arches with keystones, etc.

3. Windows and glass.

a. Large window units.

1. Historic window units of the size and character of the time period shall be required. Said retail shop windows shall be limited to their glass size of approximately 36 square feet.

2. Window units shall be raised off of the floor.

3. Adjacent window units shall have a minimum of four-inch jambs separating them both horizontally and vertically.

b. Operable window units. Operable windows shall be double hung.

c. Mullions. If mullions are used, then simulated divided lights (SDL) shall be required. The window unit is made with the mullions permanently affixed to the exterior and interior of the glass with a spacer bar placed between the two panes of glass.

d. Window frames.

1. Head and jambs shall be of a historic color and profile.

2. Traditional storefront systems shall be prohibited unless they have a permanent surface applied trim such as a snap on aluminum decorative trim, such as an Ogee profile.

3. Aluminum clad wood windows with historic details shall be permitted.

4. Wide brick moldings around the windows shall be required.

e. Glass. Clear or slightly tinted glass shall be required. Mirrored, colored or highly reflective shall be prohibited.

4. Exterior doors. Wood doors, or have the appearance of wood, with wide stiles, decorative hardware, raised panels, eight feet or taller, shall be required.

5. Building materials. Only the following building materials shall be used in combination so that a consistent, attractive, and long lasting building design can be created:

a. Walls. The main wall material shall be used on all four sides.

1. Brick. Only full thickness modular brick in earth tones shall be permitted. Thin veneer or painted brick shall be prohibited.

2. Stone. Natural stone veneer, terra cotta or cast stone which simulates natural stone in chiseled, ground face, hammered, or smooth shall be required.

3. Stucco. Masonry hard coat or building code approved synthetic stucco (EIFS) is limited to three percent of the total wall area. Use is limited to decoration, trim, or where brick or stone cannot feasibly be supported, such as in a dormer or second floor wall above a roof. Continuous EIFS banding around a building is prohibited.

4. CMU. Concrete masonry units shall be prohibited with the exception of colored split face CMU limited to three percent of the total wall area.

5. Siding. Wood, cementitious, or shakes shall be limited to upper floors only and not to exceed ten percent of total wall area. Metal siding either vertical or horizontal shall be prohibited.

b. Trim.

1. Painted wood or synthetic (Fypon, polymers) painted shall be permitted.

2. Cast stone or EIFS shall be permitted.

3. Aluminum clad wood.

4. EIFS shall be permitted in certain applications, but not as a continuous band around a building.

c. Sloped roof materials. The following materials shall be permitted if visually seen from the ground:

1. Architectural random cut, shadow line and fiberglass asphalt shingles shall be permitted and shall have a minimum wind resistance of 110 miles per hour.

2. Standing seam pre-finished metal roof in a historic color by this ordinance.

3. Copper standing seam metal roof.

4. Natural or artificial slate.

5. Wood shakes as permitted by this ordinance.

6. Cementitious or clay tile roof tiles.

6. Roof requirements.

a. Flat roofs. Flat roofs shall be of any material that meets the requirements of this ordinance as long [as] it is not seen from the ground. All flat roofs shall have parapets on all four sides of sufficient height to hide to air handling equipment form the ground for a distance of 100 feet.

b. Pitched roofs. Pitched roofs shall have a minimum pitch of 6:12. Gables and or dormers shall also be incorporated to add interest.

c. Mansard roofs. Said roofs shall be prohibited.

d. Building mechanical and accessory features.

1. All ground mounted mechanical, HVAC and like systems shall be screened from the public street view (within 100 feet) on all sides by an opaque wall or fence made of brick, stucco or landscaping.

2. Back lit awnings, roof mounted lights, and/or roof mounted flag poles are not permitted. Satellite dishes shall be located and painted to blend with the background as much as practical.

3. For all commercial/retail buildings, roof mounted mechanical, HVAC and like systems shall be screened from the public right-of-way within 100 feet on all sides.

4. When building mechanical and accessory features are located on rooftops, they shall be incorporated in the design of the building and screened with building materials similar to the building.

7. Lighting.

1. Outdoor lighting. Lighting practices include indirect lighting, which minimizes light pollution such as glare and light trespass. Carefully designed exterior lighting plans are required to provide the best balance between site safety, security, and appearance considerations. Restrained lighting patterns and fixture selection for commercial development will help prevent commercial lighting from adversely impacting residential properties. Lighting standards are generally applied and recommended by the Illuminating Engineers Society of North America.

a. Streetlight prototype. Holophane, or otherwise approved, tapered seven m pole with luminaire and banner connection as approved by the city council.

b. Walk lights. Holophane, or as otherwise approved, tapered 3.7 m pole with luminaire as approved by the city council.

c. Shielding. Exterior lighting shall be of low intensity and shielded so that light will not spill out onto surrounding properties or project above the horizontal plane of building walls.

d. Color. Warm lighting colors are encouraged, such as incandescent, halogen, metal halide, and color-corrected sodium as last choice. The blue-white colors of fluorescent and mercury vapor lamps are prohibited. Lamps emitting a color temperature in excess of 4,000 Kelvin are strongly discouraged.

e. Reduced light output. The amount of light produced by exterior light sources shall be reduced to that necessary to maintain a minimum comfort level for safety and security purposes. Most lights on or within buildings shall be extinguished after hours, and the use of motion sensors is encouraged on exterior lights. In parking lots, a minimum footcandle of 0.5 at the perimeter and between light sources, and 5.0 under light fixtures is recommended. It is suggested that rather than illuminate the whole lot after hours when most businesses are closed, a higher level of illumination only in the vicinity of the businesses still active is encouraged. When all businesses are closed, it is recommended that only a minimum of security lighting shall be maintained. No light sources are allowed higher than 175 watts.

2. Parking area lighting.

a. Appropriate location. Minimum adequate exterior lighting shall be provided in all parking areas, with particular emphasis placed on appropriate lighting at the parking lot walks, entrances, exits, and barriers. Lighting shall be of low intensity, with downward shielding to prevent glare.

b. Integration with landscaping. All parking lot lighting shall be integrated with landscaping.

c. Height. The height of light fixtures in parking lots shall be in proportion to the building mass, and no more than 16 feet high. Parking lights along walkways shall be eight to 12 feet high. Low light bollards ranging from two to eight feet should be avoided, as they provide more glare than useful light.

d. Multifamily residential lighting. Fixtures shall be located to eliminate interference with windows adjacent to the parking area.

3. Site lighting fixtures. Lighting fixtures shall be compatible with the architectural character of existing buildings and the proposed development.

4. Parking structures lighting. Lighting within the parking structure shall provide safety and security and be integrated into the architectural character, both in terms of illumination and fixtures. Light spillage out of structure is discouraged. The color of light within a parking structure shall be compatible with the outdoor lighting in adjoining areas.

10. Review and approval.

A. All building plans for nonresidential zoning districts shall be submitted to the city engineer for review prior to being submitted for a building permit. The submission is to include the following:

1. Completed application form and design review fees paid to the city.

2. Two sets of all floor plans to a minimum of one-eighth inch equals one foot scale. The plans should show all dimensions [of] windows, doors, etc.

3. Two sets of all exterior building elevations to minimum of one-eighth inch equals one foot scale. Drawings should indicate and label all building materials, features and exterior finish legend.

4. Project site plan to a minimum of one inch equals 30 feet.

5. One color drawings showing each exterior side of the building with all materials rendered correctly.

6. One material sample board with all exterior building materials used.

B. After the submission has been reviewed and all comments addressed, the city engineer shall forward the building plan to the city. The city has the option to issue a building permit after receipt of all building permit fees and/or schedule a meeting with the owner or owner's designer to review the building plan and site plans prior to issuance of a permit.

History

The history line the source prints at the end of the section.

(Ord. of 8-18-2016; Ord. of 11-10-2016)