2.2.4. Inlets (headwalls, flared end sections, etc.).
About this text
- As published by Municode, current through 2026-05-11
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
Inlets that utilize the opening of the pipe as the inlet (i.e. headwalls, flared end sections, etc.) shall be sized to capture the storm event specified for the pipe system to which it drains. The HGL should be designed to be no less than six inches below the edge of pavement or the point at which water would bypass the inlet (i.e. bypass to another inlet, etc.) whichever is less. Additionally, the headwater conditions induced by the inlet should not cause an impact on any upstream drainage structures such that the upstream structure will realize a loss in performance. In simpler terms, the headwater from an inlet should not back water into another culvert or drainage system. This requirement can be waived by the county engineer in situations where it would be infeasible to design the culverts due to proximity of the culverts or extremely shallow grades between the culverts.